DIN rails for mounting modular equipment in the electrical distribution panel

  • Professional distribution board installation guide · TH35 DIN rails

    DIN rails: how to choose, fix and fit modular equipment in an electrical distribution board?

    Perforated and unperforated TH35 rails, 35×7.5 and 35×15 mm profiles, 1–2 m lengths, modular device compatibility, fixing points, loads, assembly mistakes and technical recommendations.

    35 mm
    Standard width
    7.5 / 15
    Rail height, mm
    1–2 m
    Catalogue length options
    TH35
    Top-hat / omega rail
    EN 60715
    Mounting rail dimensions
    Kibirkštis Fazė Kibirkštis asks – Fazė explains the principles of design, installation and safety.
    Key idea

    A DIN rail is a mechanical mounting system for electrical equipment. Standardised flanges allow compatible modular components to be clipped on, while the rail itself is securely fixed to the board or structure. Suitability is determined by the profile, its dimensions, material, fixing distances and the equipment manufacturer's installation requirements. A 35 mm width alone is not enough to make the choice for every project.

    Which DIN rail to choose? Quick selection

    Selecting a DIN rail starts with the mounting type of the modular equipment, the board design and the load. A different rail height can change the position of the mounted equipment and its distance to the board's front cover.

    Need Selection direction What to check?
    Standard MCBs in a domestic consumer unit TH35 35×7.5 mm, if provided for in the board design Module fixing, board depth, cover
    Deeper rail or higher mechanical load Consider 35×15 mm Load-bearing capacity, mounting supports, free depth
    Quick screwing to a mounting plate Perforated DIN rail Hole layout and fixing points
    Specially selected fixing points Unperforated rail Fixings, drilling, corrosion protection
    Larger board wiring TH35 rail of suitable length Module width, terminals, brackets, reserve
    Larger power supply or transformer Check the permitted mounting of the device Weight, vibration, DIN latch and rail loads
    Damp or corrosive environment Material and coating suitable for the environment Corrosion, condensation, board sealing

    DIN rail range matrix

    When choosing a rail, it is important to assess its height, perforation and length separately. The sizes listed below are available in the category. The specific range and stock levels may change.

    Type Width × height Length Note
    Perforated TH35 35×7.5 mm 1 m Lower rail with fixing holes
    Perforated TH35 35×7.5 mm 2 m Longer rail, can be cut to board dimensions
    Perforated TH35 35×15 mm 1 m Higher rail with holes
    Perforated TH35 35×15 mm 2 m Higher rail for longer runs
    Unperforated TH35 35×7–7.5 mm, depending on the product 1 m and others subject to availability Solid rail; check the exact product height

    View DIN rails in the elsprendimai.eu catalogue →

    TH35 rails: 35×7.5 mm and 35×15 mm

    Both rails have the same nominal width – 35 mm. They differ in rail height, i.e. the distance between the base and the flanges holding the equipment. This affects structural rigidity and the position of modular devices in the board.

    Property 35×7.5 mm 35×15 mm
    Rail width 35 mm 35 mm
    Rail height 7.5 mm 15 mm
    Equipment mounting On the TH35 flanges On the TH35 flanges
    Board depth requirement Smaller Larger
    Mechanical rigidity Depends on material, thickness and fixing A higher rail can often be stiffer, but the construction must be checked
    Application Standard modular distribution boards Control cabinets and structures where a higher rail is specified
    ⚠ A higher rail does not automatically mean a higher permissible load. Structural strength is also determined by metal thickness, the number of fixing points and the distance between them. If you replace a 7.5 mm rail with a 15 mm rail in an already assembled board, check that the modular equipment will still align properly with the board's front panel.

    Perforated or unperforated DIN rail – which to choose?

    The main difference between a perforated and an unperforated DIN rail is the fixing holes in its base. In both cases, electrical modular equipment is clipped onto the rail flanges.

    Perforated DIN rail

    The rail base has factory-made holes or slots for screws. They can be used to screw the rail to a properly prepared board base or mounting plate.

    Advantages:
    • Convenient choice of fixing points.
    • Quick installation without additional drilling, if the holes align.
    • Convenient planning of rail layout and adjustment.
    Limitation: the hole layout and the load-bearing capacity of the rail must suit the construction.
    Unperforated DIN rail

    The rail base is solid, without pre-made fixing holes. The fixing method can be selected individually, depending on the construction.

    Advantages:
    • Solid rail base.
    • Ability to plan individual fixing points.
    • Convenient adaptation to special assembly solutions.
    Limitation: fixing may require additional work or special brackets.
    ⚡ Common misconception: perforation by itself does not improve board cooling enough to change the thermal requirements of electrical equipment. The thermal regime of the board is determined by component losses, enclosure design, layout, clearances and ventilation. Holes in a DIN rail are no substitute for proper thermal design.

    Materials, metal thickness and protective coating

    DIN rails are made of steel, aluminium and, for special purposes, other metallic materials. Steel rails with a corrosion-protected surface are most commonly used in distribution boards.

    Property Relevance for installation
    Steel A strong material, commonly used for standard distribution board DIN rails.
    Aluminium A lighter material; the rigidity and load-bearing capacity of a specific rail must be assessed separately.
    Metal thickness Important for mechanical strength and rail deformation. The catalogue includes, for example, a 1.0 mm thick unperforated steel version.
    Zinc or other protective coating Reduces the risk of corrosion in an operating environment that matches the coating's intended use.
    Precise rail edges Ensure correct operation of the latches of compatible modular devices.
    Cut quality After cutting, no sharp burrs should remain that could damage wires or hinder installation.

    How is modular equipment mounted on a DIN rail?

    A DIN rail acts as a standardised mechanical holder. Many modular devices have a special mounting profile or spring latch on the back that hooks onto the rail edges.

    1. Fixing the rail
    The rail is rigidly fixed to the board brackets or mounting plate.
    2. Hooking the device
    The device's mounting mechanism is hooked onto the DIN flange.
    3. Latching
    A spring or other latching system holds the component in place.
    4. Check
    It is checked that the equipment does not move, does not unhook and meets the required clearances.

    Some devices may have special brackets, additional screw fixing or a different mounting method. Not every board component is automatically compatible with a TH35 rail.

    Which electrical components can be mounted?

    Circuit breakers – MCB
    For protecting electrical circuits against overloads and short circuits.
    RCD and RCBO
    For residual current protection and combined circuit protection.
    Contactors and relays
    For switching electrical loads and control circuits.
    Time and monitoring relays
    For delay, sequence, voltage and phase monitoring functions.
    Surge protective devices
    When the device has a mechanism designed for a DIN rail.
    Terminal blocks
    For connecting, marking and distributing wires.
    DIN power supplies
    For automation, controllers and other extra-low-voltage equipment.
    PLCs and control modules
    For control and signal equipment in automation cabinets.
    Important: not only the modular equipment, but also its DIN latch must be compatible with the dimensions of the chosen rail. Width, depth, weight and mounting position of different components may vary.

    How to calculate how many modules fit on a DIN rail?

    A common width unit for modular equipment is about 17.5 mm, but many products may be 18 mm wide or have non-standard dimensions. Therefore, an exact calculation must be based on the actual width of the selected equipment, not just on the rail length.

    Approximate formula:
    N = Luse / M
    N – number of modules that fit; Luse – usable rail length in millimetres; M – width of one module in millimetres.
    Rail length Theoretical number of 17.5 mm modules Theoretical number of 18 mm modules
    200 mm 11 11
    300 mm 17 16
    400 mm 22 22
    500 mm 28 27
    1000 mm 57 55
    ⚠ This is only a geometric calculation. The table does not take into account end stops, gaps between devices, wire connection zones, heat dissipation, mounting brackets or cut-outs in the board's front panel. The real number of modules may be lower.

    Practical example of a 12-module row

    If 18 mm wide modules are used, 12 modules occupy 216 mm. Suppose an additional 15 mm is allowed at each end for end brackets and a mounting reserve. In that case, a usable width of at least 246 mm is required. If the construction requires larger gaps or there are non-standard devices, the length is recalculated.

    Another example: six 1-module MCBs, one 2-module RCD and one 2-module surge protective device make up 10 nominal modules. However, in a real board, space for connections, wire routing and thermal clearances must also be provided.

    Mechanical load – how much equipment can a DIN rail hold?

    The permissible load of a DIN rail is not universal just because it is a TH35 rail. Even rails of the same width can differ in strength due to steel thickness, material, perforation, length and supports.

    Factor Why is it important?
    Metal thickness Affects the rail's resistance to deformation.
    Rail height Can affect structural rigidity and equipment position.
    Supports and fixing points Longer unsupported spans can increase rail deflection.
    Equipment mass and centre of gravity Deep and heavy devices can create an additional bending moment.
    Vibration and shocks Require reliable fixing, sometimes additional fastening means.
    Mounting orientation Not all devices allow any position.
    ⚡ There is no single safe kilogram value for all 35 mm DIN rails. Heavy transformers, high-power power supplies or other massive equipment must be fixed in accordance with their own and the rail's mounting requirements. If necessary, additional supports or separate mechanical fixing are used.

    DIN rail technical parameters table

    Parameter Available options / value
    Purpose Mounting of modular electrical and automation equipment
    Main profile TH35, “top-hat” / “omega”
    Nominal width 35 mm
    Nominal height 7.5 or 15 mm; other products marked separately
    Length options 1000 and 2000 mm; other catalogue options possible
    Perforation Perforated and unperforated
    Material Usually steel; aluminium or other options possible
    Coating Depending on the product: zinc or other corrosion protection
    Metal thickness Depending on the specific product; 1.0 mm in one unperforated version
    Fixing To the mounting plate or board structure with screws / brackets
    Standard IEC / EN 60715, if declared for the specific rail
    Permissible mechanical load Depends on construction and fixing
    Electrical function Primarily a mechanical holder; a special electrical function only in an approved system
    IP protection rating An open rail itself does not have the IP rating typical of a board enclosure

    How to plan the DIN rail layout in a board correctly?

    When planning a distribution board, it is important not only to fit all devices, but also to ensure convenient wire connection, maintenance, marking and possible expansion.

    1. Count the components
    MCBs, RCDs, RCBOs, relays, contactors, power supplies and terminals.
    2. Add up the actual widths
    Use the technical dimensions of the specific devices.
    3. Leave a reserve
    Provide space for additional equipment and servicing.
    4. Consider heat
    Heat-generating devices may need additional clearances.
    5. Plan cable ducts
    Plan cable routing and DIN rails separately.
    6. Check the front cover
    The equipment must align with the board's modular window or cover design.

    If DIN rails are installed in several rows, suitable spacing between the rows must be provided. This is especially important for long terminals, deeper power supplies and devices that require convenient wire connection.

    DIN rail and electrical safety: does a metal rail need to be earthed?

    A metal DIN rail is electrically conductive, but its main function is the mechanical fixing of equipment. In some special terminal systems, the rail itself may be designed as part of the protective bonding circuit, but this requires a clearly approved system of contacts and rail.

    ⚡ The most important rule:
    • Do not assume that any DIN rail is automatically suitable for protective PE bonding.
    • PE terminals must ensure a reliable protective conductor connection according to their design and installation requirements.
    • If the rail is used as an electrically relevant part of the PE system, a designated rail connection, assessment of its continuity and appropriate instructions are required.
    • Do not assume that incidental contact between a steel rail and a painted mounting plate is sufficient.

    Protective bonding requirements for the board enclosure, doors, mounting plate and other conductive parts are addressed at the level of the entire switchgear assembly. The presence of a DIN rail by itself does not replace a verified earthing system.

    DIN rail corrosion resistance and operating environment

    Inside distribution boards, condensation, temperature changes and a more aggressive chemical environment may occur. This is important when choosing the DIN rail material and protective coating.

    Environment Recommended check
    Dry indoor distribution board Standard rail construction and compatibility
    Heated technical room Temperature changes and the thermal regime of components
    High-humidity environment Coating suitability, condensation control, enclosure sealing
    Industry with chemical exposure Resistance of material and coating to specific substances
    Vibration and mechanical loads Rail fixing construction and equipment latches
    What about IP? A DIN rail by itself is not an IP65 or IP67 device. The level of protection against dust and water is determined by a properly selected board enclosure with its entries, doors and sealing elements.

    DIN rail installation – step by step

    1. Measure the space
    Determine the free width and depth of the board, the fixing points and the layout of the planned equipment.
    2. Choose the rail
    35×7.5 or 35×15 mm, perforated or unperforated.
    3. Measure the length
    Take into account devices, end brackets, reserve and installation clearances.
    4. Cut the rail
    Use a tool suitable for metal without damaging the rail shape.
    5. Remove burrs
    Smooth sharp edges and clean off metal shavings.
    6. Fix the rail
    Use screws and supports suitable for the board construction.
    7. Mount the equipment
    Latch the components and fit the required end stops.
    8. Carry out a check
    Check stability, cover fit, wire protection and electrical safety.

    Before working in a distribution board, the power supply must be safely disconnected and the absence of voltage verified. When cutting or drilling a metal rail, make sure metal shavings do not fall onto installed electrical equipment.

    Most common DIN rail selection and installation mistakes

    ✗ Wrong ✓ Right
    Perforations are treated as mounting points for modular devices. Fix devices to the DIN rail flanges; use perforations for fixing the rail.
    A 35×15 mm rail is fitted without checking the board depth. Check equipment height and compatibility with the board cover.
    A long rail is left without sufficient supports. Choose a suitable number of fixing points and spacing.
    The weight of heavy components is not considered. Check the mechanical load and the need for additional fixing.
    Sharp edges are left after cutting. Deburr and remove metal shavings.
    All components are crammed in without service space. Provide installation, thermal and wire connection clearances.
    The protective PE bonding system is not considered. Install according to the instructions of the specific board and PE terminals.
    The DIN rail is treated as a cable duct. Use separate ducts, fixing and protective means for wires.

    Checklist before ordering and installation

    1. Profile
    TH35 or another type of mounting rail?
    2. Height
    35×7.5 or 35×15 mm?
    3. Perforation
    Are factory fixing holes required?
    4. Length
    How many millimetres are needed for a specific board row?
    5. Material
    Is the metal construction and coating suitable?
    6. Load
    How much do the devices weigh and how are they fixed?
    7. Compatibility
    Are all components designed for this DIN rail?
    8. Accessories
    Are end brackets, terminals and cable ducts needed?

    Fazė's recommendations for panel builders

    Fazė
    Fazė advises

    When choosing a DIN rail, first check the construction of the existing board. If the board has factory DIN rail supports, the new rail must exactly match their height and fixing system. Only then decide whether to use a perforated rail or a solid one. A taller 35×15 mm rail is not an automatic upgrade if the devices will no longer fit under the cover because of it.

    For a standard consumer unit

    Check the TH35 35×7.5 mm options and the board fixing construction.

    For an automation cabinet

    Consider a 35×15 mm rail, mechanical loads and the required free depth.

    For quick fixing

    A perforated rail is useful if the prepared holes align with the fixing points.

    For a special construction

    For an unperforated rail, plan a suitable fixing method in advance.

    Diagram: incorrect and correct DIN rail installation

    ✗ WRONG
    Distribution board
    ↓
    Wrong height, insufficiently fixed DIN rail
    Load and board cover not considered
    ↓
    Loose, shifted equipment

    Possible rail deflection, unhooked components and an unsuitable distribution board construction.

    ✓ RIGHT
    Board design and dimensions
    ↓
    Suitable TH35 rail and supports
    Depth, load and fixing verified
    ↓
    Neatly installed modular equipment

    The rail is selected according to the board construction and component fixing requirements.

    FAQ – Kibirkštis asks, Fazė answers

    15 practical questions about DIN rails: profile dimensions, purpose of perforations, mounting of modular devices, mounting depth, mechanical loads, panel assembly and electrical safety.

    Kibirkštis
    KIBIRKŠTIS ASKS · 01

    What is a DIN rail and why is it needed in an electrical panel?

    Fazė
    FAZĖ ANSWERS

    A DIN rail is a standardised metal mounting profile to which compatible electrical components are attached: MCBs, relays, contactors, terminals, power supplies and other devices. The most commonly used is the 35 mm wide TH35 profile. Its edges allow equipment to be quickly attached and, if necessary, removed. A DIN rail is primarily a mechanical support – it does not itself protect the circuit against overload or short circuit.

    Kibirkštis
    KIBIRKŠTIS ASKS · 02

    What is the difference between a perforated and a non-perforated DIN rail?

    Fazė
    FAZĖ ANSWERS

    A perforated rail has factory-made fixing holesfor screwing it to a mounting plate or panel structure. A non-perforated rail has a solid base, so its fixing points are chosen according to the specific structure. Modular equipment can be attached to the standard profile edges of both types. Therefore, a perforated rail is worth choosing when its hole pattern makes mounting the profile more convenient, not because of a supposedly different way of fixing MCBs.

    Kibirkštis
    KIBIRKŠTIS ASKS · 03

    Are MCBs fixed through the holes of a DIN rail?

    Fazė
    FAZĖ ANSWERS

    No. Standard modular MCBs have a DIN clip mechanism that hooks onto the edges of the TH35 profile. The rail perforations are intended for screwing the profile itself to the structure. Therefore, compatible MCBs can also be mounted on a non-perforated DIN rail. It is important to check that their clips lock reliably and that the rail is properly fixed to the panel.

    Kibirkštis
    KIBIRKŠTIS ASKS · 04

    What is the difference between 35×7.5 mm and 35×15 mm DIN rails?

    Fazė
    FAZĖ ANSWERS

    Both profiles have a nominal width of 35 mm, but they differ in height. 35×7.5 mm profile is lower, while 35×15 mm is higher. A higher profile may have different mechanical properties, but its strength also depends on the metal thickness, material and fixing points. If the rail is mounted in a panel with a front modular cover, check whether the front parts of the devices will remain in the correct position after changing the profile height.

    Kibirkštis
    KIBIRKŠTIS ASKS · 05

    Is a 35×15 mm DIN rail always stronger and suitable for heavy equipment?

    Fazė
    FAZĖ ANSWERS

    Not always. A higher profile may be stiffer under certain conditions, but the 35×15 mm dimension alone does not guarantee a specific load-bearing capacity. Assess the metal thickness, profile, support spacing, screws used and component weight. Larger power supplies, transformers or equipment that creates additional mechanical torque may need additional fixing. The final decision is determined by the parameters of the entire mounting system.

    Kibirkštis
    KIBIRKŠTIS ASKS · 06

    How many MCBs can be mounted on one metre of DIN rail?

    Fazė
    FAZĖ ANSWERS

    If one module of a device is 17.5 mm wide, theoretically about 57 such modulesfit on a 1000 mm rail. If the module width is 18 mm – about 55. However, this is only a geometric limit. In practice, space must be left for end stops, wire connections, heat dissipation and possible panel expansion. In addition, not all devices are one module wide – RCDs, contactors and other components may occupy several modules.

    Kibirkštis
    KIBIRKŠTIS ASKS · 07

    Can a two-metre DIN rail be shortened to the required length?

    Fazė
    FAZĖ ANSWERS

    Yes, most standard steel DIN profiles can be cut to the planned panel dimensions with suitable metalworking tools. The profile shape must be preserved, and sharp cutting burrs and metal chips removed. Also make sure the rail ends do not obstruct the enclosure walls, cable ducts and device clips. The fixing points of the cut profile must remain sufficient for its load.

    Kibirkštis
    KIBIRKŠTIS ASKS · 08

    Does a DIN rail need to be earthed if it is metal?

    Fazė
    FAZĖ ANSWERS

    Protective bonding requirements for metal parts are determined by the construction of the whole panel. In some systems, the DIN rail may be included in the PE bonding solution, but this requires reliable and approved contacts and appropriate installation. Do not assume that the rail merely touching a painted metal enclosure is sufficient. Nor can any rail automatically be considered a suitable substitute for a PE conductor. Follow the technical requirements of the panel and the PE terminal system.

    Kibirkštis
    KIBIRKŠTIS ASKS · 09

    Does a perforated rail ventilate the panel better and protect MCBs from overheating?

    Fazė
    FAZĖ ANSWERS

    It’s not that simple. Perforations are intended for fixing, and their effect on the ventilation of the whole panel is usually not decisive. Device temperature is affected much more by their heat losses, spacing between components, wiring layout, panel size, air circulation and ambient temperature. Therefore, a perforated DIN rail does not replace proper thermal design of the panel and does not allow the permissible temperature of modular devices to be exceeded.

    Kibirkštis
    KIBIRKŠTIS ASKS · 10

    Can I mount a contactor, a relay and a power supply in one row on a DIN rail?

    Fazė
    FAZĖ ANSWERS

    Yes, if all devices have a mounting system compatible with that profile and permit such a mounting position. However, their depth, weight, heat dissipation and wire connection points matter. Power supplies and contactors sometimes need additional clearances for ventilation. Therefore, the fact that all three products “snap” onto a TH35 rail is not enough – their technical installation instructions must also be checked.

    Kibirkštis
    KIBIRKŠTIS ASKS · 11

    How to fix a long DIN rail correctly so that it doesn’t bend?

    Fazė
    FAZĖ ANSWERS

    What matters is not only the rail length but also the spacing between fixing points, the stiffness of the mounting plate and the weight of the equipment. A longer profile may need several supports so that it does not deform when being screwed down or loaded. On a perforated rail, use suitably spaced holes; for a non-perforated rail, provide a reliable fixing method. There is no universal rule that two screws are enough for every rail.

    Kibirkštis
    KIBIRKŠTIS ASKS · 12

    Are DIN rails suitable for damp rooms and outdoor electrical panels?

    Fazė
    FAZĖ ANSWERS

    They can be used if their material and protective coating suit the environmental conditions. Condensation may form inside an outdoor panel, so proper enclosure sealing, ventilation or condensation control and corrosion resistance are important. The DIN rail itself does not have the IP65 or IP67 protection rating typical of a panel. Such protection applies to a properly installed enclosure and its sealing system.

    Kibirkštis
    KIBIRKŠTIS ASKS · 13

    Do all DIN rails have to be made of steel?

    Fazė
    FAZĖ ANSWERS

    No. Steel DIN profiles are most common, but there are also aluminium and other special variants. The choice of material depends on the required stiffness, corrosive environment, structural weight and electrical system requirements. Profiles made of different materials do not automatically have the same mechanical load capacity. If the rail also performs an electrical function in the mounting system, the characteristics approved for the specific construction must be checked.

    Kibirkštis
    KIBIRKŠTIS ASKS · 14

    Which standards apply to DIN rails and what does DIN 46277 mean?

    Fazė
    FAZĖ ANSWERS

    IEC / EN 60715 defines the dimensions of standardised mounting rails for low-voltage electrical equipment. DIN 46277 is a standard designation of DIN profiles widely used in older technical literature. Nevertheless, the name “DIN rail” alone is not enough – when choosing a specific product, its geometric dimensions, profile, declared conformity and compatibility with the intended modular equipment must be checked.

    Kibirkštis
    KIBIRKŠTIS ASKS · 15

    What information should I provide so the right DIN rail can be selected?

    Fazė
    FAZĖ ANSWERS

    State the preferred profile, for example 35×7.5 or 35×15 mm, whether a perforated rail is needed, as well as the length, quantity and installation location. If heavy devices will be mounted on the profile, it helps to state their weight and the mounting structure. If you are replacing an old rail, its dimensions or a photo would help. This allows a more accurate assessment of suitability and selection of a variant that matches the panel construction.

    Kibirkštis Fazė Kibirkštis and Fazė remind you

    DIN rail selection starts with the panel construction. Check the profile width and height, mounting type, mechanical load, component compatibility and electrical safety requirements.

    Standards, technical notes and compatibility

    The following technical documents and standard requirements are important for DIN rail mounting and compatibility decisions:

    • IEC / EN 60715 – dimensions and profiles of standardised mounting rails for low-voltage electrical equipment.
    • DIN 46277 – traditional designation of DIN profiles, often found in technical literature.
    • IEC / EN 61439 – construction and verification requirements for low-voltage switchgear and controlgear assemblies.
    • LST HD 60364 – installation and electrical safety requirements for low-voltage electrical installations.
    • Device installation instructions – specify which DIN profile, orientation, end stops and mechanical support are permitted.
    • DIN rails category – elsprendimai.eu.
    • Electrical distribution panels, boxes and accessories.
    • Earthing terminals for electrical panels.
    Important technical information

    DIN rail profile dimensions, material, surface coating, perforations and metal thickness may vary. The same 35 mm nominal width does not confirm the same load-bearing capacity or compatibility with an enclosure of any depth.

    Perforations are intended for fixing, not for additional electrical protection or mechanical fixing of MCBs. A DIN rail must also not be considered a universal substitute for a protective PE conductor.

    Liability and usage note: the technical explanations, module calculation examples and installation recommendations provided are for information only. The equipment layout, mechanical fixing, earthing solution and electrical safety inspection of a specific electrical panel must be carried out by a competent specialist in accordance with the requirements of the design, the equipment and applicable legislation. The liability of UAB “Elektrotechnikos sprendimai” is determined in accordance with applicable law.

    Need DIN rails for panel assembly?

    State the required TH35 profile height, length, perforation, quantity and intended installation location. We will help choose the right variant and check its availability.

    Contact Elsprendimai.eu

    DIN rails are standardized mounting rails designed for modular electrical equipment such as relays, automation devices, switches, circuit breakers, and other components to be mounted in electrical distribution boards. These rails comply with DIN 46277 standards and are widely used in both industrial and commercial as well as residential applications.

    Main Features:

    Material and Construction: DIN rails are typically made from high-quality steel or aluminum, ensuring strength and durability. They are often coated with special finishes to protect against corrosion.

    Standardized Dimensions: The rails have standardized dimensions, allowing easy integration of various modular equipment. The most commonly used rails are 35 mm wide, although other width options may also be available.

    Ease of Installation: DIN rails are designed for easy installation and removal. Equipment is secured using special locks or screws, ensuring a safe and stable connection.

    Cable Management: The rails provide the ability to neatly organize cables and wires, helping to ensure better air circulation and reduce the risk of electrical faults.

    Versatility: DIN rails can be used in various fields, including industrial manufacturing, commercial spaces, and residential homes. They allow for easy modification or expansion of electrical systems to adapt to changing needs.

    Perforated Rails: Perforated DIN rails have special holes or perforations that allow easy attachment of modular equipment. These perforations provide more flexibility for installing equipment in different positions.

    Advantages:

    Installation Flexibility: The perforations allow for different mounting locations, making it possible to use space more efficiently and adapt the rails to specific needs.
    Air Circulation: The perforations help improve ventilation in areas where modular equipment is installed, thus reducing the risk of overheating.
    Weight Reduction: Perforated rails are often lighter than solid ones, making them easier to transport and install.
    Non-Perforated Rails: Non-perforated DIN rails are sturdy and stable without perforations. They are typically used when greater strength and stability of the rail is required.

    Advantages:

    High Strength: Non-perforated rails are particularly robust, making them ideal for heavier modules or situations requiring greater resistance.
    Easier Cleaning: Due to their smooth surface structure, non-perforated rails are easier to clean and maintain.
    Aesthetic Appearance: Smooth rails often look more elegant and are better suited for certain environments where aesthetics are important.
    Usage: DIN rails, both perforated and non-perforated, are ideal for various modules such as automatic switches, relays, circuit breakers, phase monitoring devices, and more. They help efficiently organize electrical distribution systems, ensuring safety and functionality.

    DIN rails for mounting modular equipment in electrical distribution boards are an essential element that enables the effective and safe integration of various electrical systems. Both perforated and non-perforated rails offer unique advantages, allowing them to be tailored to specific project requirements. 

    Read more
    Perforated DIN rail | profile | for mounting modular equipment in a distribution cabinet | 35x7.5mm | 250mm | Promfactor Baltic FD010250
    Code: FD010250

    Promfactor Baltic FD010250 is a high-quality perforated DIN rail designed for reliable and quick installation of modular equipment in distribution panels. It features durability, temperature resistance, and easy installation but may have limited use in larger installations due to its short length.

    Price 0.51 € VAT incl.
    ( 0.42 € VAT excl. )
    Perforated DIN rail | profile | for mounting modular equipment in a distribution cabinet | 35x7.5mm | 1000mm | Promfactor Baltic FD011000
    Code: FD011000

    Promfactor Baltic FD011000 perforated DIN rail is a high-quality, reliable, and widely used component in electrical and automation systems. It meets industrial standards and ensures easy and secure installation of modular equipment. It is an excellent choice for both residential and industrial electrical installations.

    Price 1.14 € VAT incl.
    ( 0.94 € VAT excl. )
    Perforated DIN rail | profile for modular equipment mounting in a distribution cabinet | 35x7.5mm | 15cm
    Code: DR750150

    A perforated DIN rail is a mounting profile designed for quick and reliable installation of modular electrical equipment, such as circuit breakers, residual current relays, power supplies, or automation components, in distribution panels.
    Thanks to the perforations, the rail can be easily mounted with screws directly onto the panel base, ensuring a firm and stable hold of the structure even under vibration or heavier loads. 

    Price 0.52 € VAT incl.
    ( 0.43 € VAT excl. )
    Non-perforated DIN rail | profile | for mounting modular equipment in a distribution board | 35x7mm | 1m | BAKS | EURO | SZB35H 7/1 | 0613310
    Code: 0613310

    BAKS EURO SZB35H 7/1 – a non-perforated steel DIN rail designed for mounting modular electrical and automation equipment in distribution boards and control cabinets. Profile dimensions – 35 × 7 mm, steel thickness – 1.0 mm, length – 1000 mm (1 m). The solid non-perforated base allows mounting points to be selected according to the specific construction; the price is indicated per 1 metre. 

    Price 0.88 € VAT incl.
    ( 0.73 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information