Products catalog

Domestic inline duct fans | for ventilation systems

  • Domestic duct fans | D100–D160 | 12 V and 230 V | selection guide

    Compact insert fans and in-line duct fans for bathroom, kitchen, basement, garage and off-grid ventilation – selection by duct, power supply and airflow.

    Key idea:
    A domestic duct fan is selected by three things: duct diameter (D100–D160), power supply (12 V DC or 230 V) and the required airflow. A compact insert fan fits straight into the duct; an in-line fan with brackets is quieter and more powerful for longer duct runs.

    ☝ Selection in 30 s

    1. Duct diameter
    Measure the round duct diameter: 100, 125, 150 or 160 mm. The fan should match the duct without reducers.
    2. Power supply
    230 V – for the standard home mains. 12 V DC – for a battery, solar system or low-voltage system.
    3. Airflow
    Room volume × air changes per hour. Choose a model with a 20–30 % margin for duct resistance.
    4. Mounting location
    Short duct or duct end – compact insert fan. Long run in the attic – in-line fan with brackets.

    What do you need?

    1. Bathroom or toilet extraction
    A standard bathroom or toilet with a Ø100 mm duct.
    230 V D100 compact · 230 V D100 in-line
    2. Off-grid system, campervan, garden cabin
    Ventilation from a 12 V battery or solar system, without an inverter.
    12 V DC D100 · 12 V DC D125
    3. Kitchen or larger bathroom
    Higher airflow, Ø125 mm duct.
    230 V D125 compact · 230 V D125 in-line
    4. Basement, laundry, garage
    Larger volumes and humidity – Ø150–160 mm.
    230 V D150 compact · 230 V D160 compact
    5. Long run in the attic or ceiling
    Fan further from the room – less noise, servicing without dismantling the duct.
    230 V D160 in-line · 230 V D125 in-line
    6. Industrial premises, high airflow
    When hundreds or thousands of m³/h are needed – choose industrial duct fans.
    Industrial duct fans

    Matrix: duct diameter × fan type

    Duct 12 V DC compact 230 V compact 230 V in-line
    Ø100 mm 12 V DC compact D100
    107 m³/h · 14 W · 35 dB(A)
    230 V compact D100
    107 m³/h · 14 W · 35 dB(A)
    230 V in-line D100
    115 m³/h · 14 W · 32 dB(A)
    Ø125 mm 12 V DC compact D125
    190 m³/h · 18 W · 36 dB(A)
    230 V compact D125
    190 m³/h · 18 W · 36 dB(A)
    230 V in-line D125
    195 m³/h · 18 W · 34 dB(A)
    Ø150 mm — 230 V compact D150
    280 m³/h · 20 W · 37 dB(A)
    —
    Ø160 mm — 230 V compact D160
    300 m³/h · 22 W · 38 dB(A)
    230 V in-line D160
    320 m³/h · 22 W · 36 dB(A)

    How much air and which duct

    Rough calculation: airflow (m³/h) = room volume (m³) × air changes per hour. Catalogue fan capacity is given without duct resistance, so choose a model with a 20–30 % margin. Exact requirements are set by the building design.

    Room Volume Changes/h Needed Duct
    Toilet ~5 m³ 8 ~40 m³/h D100
    Bathroom ~12 m³ 8 ~100 m³/h D100–D125
    Kitchen ~25 m³ 6 ~150 m³/h D125
    Laundry, basement ~35 m³ 6 ~210 m³/h D150
    Garage ~50 m³ 5 ~250 m³/h D150–D160

    The table is indicative – actual air exchange depends on room use, duct length and number of bends.

    12 V or 230 V?

    12 V DC
    Powered from a battery, solar system or 12 V power supply. Suits off-grid systems, campervans and garden cabins. Observe polarity; the power supply is not included.
    230 V AC
    Connected to the standard home mains via a switch, timer or humidity relay. The widest choice of sizes – D100–D160. The connection is made by an electrician.

    Compact or in-line?

    Compact insert fan
    A short housing (80–104 mm) fits straight into the duct or at the duct end. Suits boosting an existing duct and tight spaces.
    In-line fan with brackets
    Fixed with brackets, mounted vertically, horizontally or diagonally. Quieter and more powerful, serviced without dismantling the whole duct – suits long attic runs.

    Kibirkštis asks – Fazė answers

    Kibirkštis
    Kibirkštis: Can a 12 V fan be connected to 230 V?
    Fazė
    Fazė: No – it needs a 12 V DC source. For 230 V mains choose a 230 V model.
    Kibirkštis
    Kibirkštis: Can the fan be used for air supply?
    Fazė
    Fazė: Yes, airflow direction depends on the mounting position – check the arrow on the housing.
    Kibirkštis
    Kibirkštis: My duct is 125 mm and the fan is 100 mm – will it work?
    Fazė
    Fazė: Better choose the fan to match the duct. Reducers lower airflow and increase noise.
    Kibirkštis
    Kibirkštis: Do I need a check valve?
    Fazė
    Fazė: If the duct leads outside or into a shared shaft – yes, to stop cold air and odours blowing back.
    Kibirkštis
    Kibirkštis: How to reduce noise in the bathroom?
    Fazė
    Fazė: Choose an in-line fan and install it further from the room, e.g. in the attic.

    ⚡ Common mistakes

    ✗ Fan chosen by maximum catalogue capacity
    ✓ Choose with a 20–30 % margin for duct resistance.
    ✗ 12 V fan connected without a proper source
    ✓ Use a 12 V DC power supply or battery and observe polarity.
    ✗ Smaller fan with a reducer
    ✓ Choose the fan by duct diameter.
    ✗ Fan installed in the wrong direction
    ✓ Check the arrow on the housing before installation.
    ✗ Compact model in a hot zone
    ✓ Operating temperature is not specified – do not install in a sauna steam room or near hot surfaces.

    Safety

    Danger: connecting a 230 V fan while live, installing in bathroom zones without following the rules, a 12 V power supply in a wet zone.
    Solution: disconnect the power before installation; the 230 V connection is made by a qualified electrician; in bathrooms follow the zone requirements (HD 60364-7-701); install the 12 V power supply outside the wet zone.

    What else you need

    Fan speed controllers
    for quieter operation and airflow control
    Plastic ducts
    for the run from the fan to the outlet
    Plastic duct flanges
    for joining and fixing ducts
    Supply air vents
    for fresh air supply to rooms
    Protective grilles
    for the duct outlet outside
    Deflectors
    to boost draught at the roof outlet
    Extractor fans with timer and humidity sensor
    for wall mounting in the bathroom
    Didn't find it? Ask us
    Tell us which room and duct you need a fan for – in the chat window (bottom right) or by e-mail. We will select the model and the accessories you need.

    About domestic duct fans

    Domestic duct fans are installed in round Ø100–160 mm ducts and used for supply or exhaust air in bathrooms, toilets, kitchens, laundries, basements and garages. Compact insert models suit boosting an existing duct, in-line models with brackets suit longer runs and quieter operation. 12 V DC versions are designed for off-grid and low-voltage systems.

    This guide is for indicative selection. UAB „Elektrotechnikos sprendimai“ is not responsible for selection based on this guide alone – the final decision is made by a designer or a qualified specialist.

    Read more
    In-line duct fan | 230 V | D160 | 22 W | 320 m³/h | with brackets | IP24 | plastic | white | Elsp Group 4130
    Code: 4130

    230 V in-line duct fan for Ø160 mm ducts: 22 W, up to 320 m³/h, 36 dB(A), IP24, brackets included, mounts in any orientation – for supply or exhaust.

    Price 34.90 € VAT incl.
    ( 28.84 € VAT excl. )
    In-line duct fan | 230 V | D100 | 14 W | 115 m³/h | with brackets | IP24 | plastic | white | Elsp Group 4128
    Code: 4128

    230 V in-line duct fan for Ø100 mm ducts: 14 W, up to 115 m³/h, 32 dB(A), IP24, brackets included, mounts in any orientation – for supply or exhaust.

    Price 24.90 € VAT incl.
    ( 20.58 € VAT excl. )
    In-line duct fan | 230 V | D125 | 18 W | 195 m³/h | with brackets | IP24 | plastic | white | Elsp Group 4129
    Code: 4129

    230 V in-line duct fan for Ø125 mm ducts: 18 W, up to 195 m³/h, 34 dB(A), IP24, brackets included, mounts in any orientation – for supply or exhaust.

    Price 27.90 € VAT incl.
    ( 23.06 € VAT excl. )
    Duct fan | domestic | 230 V | D100 | 103×103×80 mm | IP24 | for supply and exhaust | plastic | white | Elsp Group 10152
    Code: 10152

    Compact 230 V duct fan for Ø100 mm ducts: 14 W, up to 107 m³/h, 35 dB(A), IP24 – for bathroom, kitchen, storeroom and garage ventilation, supply or exhaust.

    Price 14.90 € VAT incl.
    ( 12.31 € VAT excl. )
    Duct fan | domestic | 230 V | D125 | 128×128×87 mm | IP24 | for supply and exhaust | plastic | white | Elsp Group 10153
    Code: 10153

    Compact 230 V duct fan for Ø125 mm ducts: 18 W, up to 190 m³/h, 36 dB(A), IP24 – for bathroom, kitchen, storeroom and garage ventilation, supply or exhaust.

    Price 12.90 € VAT incl.
    ( 10.66 € VAT excl. )
    Duct fan | domestic | 230 V | D150 | 153×153×104 mm | IP24 | for supply and exhaust | plastic | white | Elsp Group 10154
    Code: 10154

    Compact 230 V duct fan for Ø150 mm ducts: 20 W, up to 280 m³/h, 37 dB(A), IP24 – for bathroom, kitchen, storeroom and garage ventilation, supply or exhaust.

    Price 15.90 € VAT incl.
    ( 13.14 € VAT excl. )
    Duct fan | domestic | 230 V | D160 | 163×163×101 mm | IP24 | for supply and exhaust | plastic | white | Elsp Group 10155
    Code: 10155

    Compact 230 V duct fan for Ø160 mm ducts: 22 W, up to 300 m³/h, 38 dB(A), IP24 – for bathroom, kitchen, storeroom and garage ventilation, supply or exhaust.

    Price 16.90 € VAT incl.
    ( 13.97 € VAT excl. )
    Duct fan | domestic | 12 V DC | D100 | 103×103×80 mm | IP24 | for supply and exhaust | plastic | white | Elsp Group 10156
    Code: 10156

    Compact 12 V DC duct fan for Ø100 mm ducts: 14 W, up to 107 m³/h, 35 dB(A), IP24 – for off-grid systems, campervans, bathroom and basement ventilation, supply or exhaust.

    Price 11.90 € VAT incl.
    ( 9.83 € VAT excl. )
    Duct fan | domestic | 12 V DC | D125 | 128×128×87 mm | IP24 | for supply and exhaust | plastic | white | Elsp Group 10157
    Code: 10157

    Compact 12 V DC duct fan for Ø125 mm ducts: 18 W, up to 190 m³/h, 36 dB(A), IP24 – for off-grid systems, campervans, bathroom and basement ventilation, supply or exhaust.

    Price 13.90 € VAT incl.
    ( 11.49 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information