Products catalog

Protective DC automatic circuit breakers for solar modules

  • Selection guide: DC circuit breakers for solar power plants

    Here you will find a quick selection by situation, solution levels from the simplest to industrial, voltage and current calculation with an example, a list of all breakers in this group, installation rules and the most common mistakes. Exact parameters are given in each product description.

    Colour legend: ■ information · ■ benefit, solution · ■ ⚠ check · ■ ⚡ safety, mistakes

    1. What do you need? Selection in 30 s

    Situation What to choose
    Home solar plant, 1–2 strings to the inverter String protection is usually not required, but isolation is mandatory: DC isolator switch. If you want automatic tripping and a manual switch in one device, choose a modular 2P 1000 V DC circuit breaker.
    3 or more parallel strings, combiner box For each string – 2P 1000 V DC breaker 16 A or 25 A according to the string Isc (calculation below). At the inverter – a common disconnecting device.
    String voltage close to 1000 V, the manufacturer requires series connection of poles Modular 4P 1000 V DC circuit breaker (poles connected in series according to the manufacturer's diagram).
    Commercial plant: combined current from the combiner box 100–250 A Industrial (MCCB type) 2P 1000 V DC breaker, e.g. 100 A or 160 A.
    Smaller system: string voltage up to 500–600 V DC 500 V or 600 V DC breakers – the voltage is given in the product name.
    Batteries, ESS, 12/24/48 V systems These breakers are in a separate group: DC circuit breakers for batteries | 12–250 VDC.

    2. Solution levels: from the simplest to industrial

    1

    Isolation: DC isolator switch

    Allows the string to be safely disconnected from the inverter during maintenance. It does not protect against overload or short circuit. Suitable for small systems with 1–2 strings. DC isolators and fuses

    2

    String protection: modular 2P breaker 500–1000 V DC

    Automatically disconnects overload and short circuit and also works as a manual switch. Mounted on a DIN rail in the combiner box. E.g. 2P 25 A 1000 V DC

    3

    High voltage: modular 4P breaker 1000 V DC

    When the string voltage is close to 1000 V, some manufacturers require 2 poles in series for each conductor. This increases the arc-quenching capability. E.g. 4P 32 A 1000 V DC

    4

    Industrial level: MCCB type 2P 100–250 A

    For the combined current of several strings between the combiner box and a central inverter. Bolted, connected with large cross-section cables. E.g. 2P 160 A 1000 V DC

    3. What a DC circuit breaker does not do

    • ⚡ It does not protect people against electric shock. Other measures serve this purpose: double insulation, earthing, insulation monitoring and residual current protection in the inverter.
    • ⚡ It does not protect against lightning and overvoltage. For this you need DC surge protective devices (SPD).
    • ⚡ An AC breaker is not suitable for a DC circuit. A DC arc does not extinguish by itself, so the breaker must be certified for DC voltage (IEC 60898-2 / IEC 60947-2).

    4. How to calculate: voltage, current, poles

    Parameter Rule
    Rated operational voltage Ue Ue ≥ string Voc at the lowest local temperature. Voc rises in the cold. In the Baltics, at ~−25 °C, it is usually ~10–15 % higher than Voc at STC. Calculate the exact value using the module temperature coefficient.
    Rated current In According to IEC 62548: 1.5 × Isc ≤ In ≤ 2.4 × Isc. In must not exceed the module's permissible reverse current (the manufacturer's “max. series fuse rating”).
    Number of poles For a PV circuit usually 2P (+ and −). If the voltage is close to the limit, follow the manufacturer's diagram: sometimes 1000 V DC requires 4P with poles connected in series.
    Polarity Most DC breakers are polarised: terminals are marked “+” and “−” or with the current direction. If polarity is reversed, the breaker may fail to extinguish the arc.
    Breaking capacity Icu / Icn Not lower than the prospective short-circuit current at the installation point.
    Installation A modular breaker is mounted on a 35 mm DIN rail in an enclosure. Outdoors, an enclosure with a suitable IP rating is required. The cable cross-section is chosen according to In and length.
    Kibirkštis

    Kibirkštis calculates: example for one string

    • Module: Voc 49.5 V, Isc 13.9 A, Voc temperature coefficient −0.27 %/°C, “max. series fuse rating” 25 A. 16 modules per string.
    • Voltage: 16 × 49.5 = 792 V at STC. At −25 °C (50 °C below STC): 792 × (1 + 0.0027 × 50) ≈ 899 V. A 1000 V DC breaker is required.
    • Current: 1.5 × 13.9 = 20.9 A, 2.4 × 13.9 = 33.4 A. 25 A or 32 A is permissible, but the module limit is 25 A. Choose 2P 25 A 1000 V DC.
    • ⚠ Check your module datasheet: the figures differ by model.

    5. All DC breakers in this group

    All breakers in this group are listed below. Exact parameters are given in each product description.

    6. Installation and safety

    • Install the breaker in a combiner box (string box) or at the inverter, on a 35 mm DIN rail. Outdoors the box must be at least IP65 and UV resistant.
    • Observe the polarity marking on the breaker housing (“+” / “−”, current direction arrow) and the manufacturer's diagram.
    • Both string conductors (+ and −) pass through the same 2P (or 4P) breaker so that the circuit is fully isolated when switched off.
    • For cables use UV-resistant solar cables and connectors. Choose the cross-section according to In and voltage drop.

    Wiring diagrams

    Diagram 1: one string – PV modules, 2P DC breaker, DC SPD T2, inverter.
    Diagram 2: combiner box for 3 strings with separate 2P breakers and a common SPD.
    Diagram 3: series pole connection of a 4P DC breaker at 1000 V DC.
    Fazė

    ⚡ Fazė's tip: a DC circuit never “switches off”

    • As long as the sun shines, the modules generate voltage. Even with the inverter disconnected, up to 1000 V DC remains in the string.
    • Do not pull MC4 connectors or open fuse holders under load: a DC arc can cause burns and damage the connectors. First switch off the inverter, then the DC breaker or isolator.
    • Never use an AC breaker instead of a DC breaker, even if the amperes match.
    • Work on PV DC circuits must be carried out by a qualified electrician.

    7. String protection kit

    Complete PV string protection in a combiner box usually requires:

    1. a DC circuit breaker (in this group) or a fuse with holder and a DC isolator switch.
    2. a DC surge protective device (SPD) Type 2, and if the building has lightning protection and the separation distance is not maintained – Type 1+2.
    3. an outdoor IP65 enclosure with a DIN rail.
    4. solar cable and MC4 connectors.

    Ready-made kits – into the cart with one click

     
     
     

    ⚠ The kits are based on an example module with Isc up to 13.9 A and “max. series fuse rating” 25 A. If your module data differ, choose the breaker current according to section 4.

    Not sure how to put a kit together? Send us your module data and number of strings – we will select a kit.

    8. Most common mistakes

    • ⚡ AC breaker installed in a DC circuit: it does not extinguish the DC arc and may catch fire.
    • ⚡ 500 V DC breaker for a 1000 V string: Ue must not be lower than Voc in the cold.
    • ⚡ Voc not calculated for winter: on a cold sunny day the voltage exceeds the STC value by 10–15 %.
    • ⚡ In too low: the breaker trips on a hot sunny day. In too high: it exceeds the module “max. series fuse rating”, the protection does not work.
    • ⚡ Reversed polarity in a polarised breaker.
    • ⚡ A PV breaker without sufficient Icu chosen for a battery circuit – batteries have a separate group.

    9. Frequently asked questions

    Is a DC circuit breaker mandatory for a home solar plant?

    When 1–2 strings are connected to the inverter, string protection against reverse current is usually not needed. A DC isolating device is mandatory: an isolator or a breaker. Many inverters have one built in, so check the inverter documentation.

    What is the difference between 6 kA, 10 kA and 50 kA?

    This is the breaking capacity – the highest short-circuit current the breaker can safely interrupt. The short-circuit current of a PV string is low, so 6 kA is enough for a string. Higher capacity matters in combined circuits and near batteries.

    What does the “C” characteristic mean?

    It is the magnetic tripping threshold, usually 5–10 × In. In PV circuits it has no significant effect on selection; Ue, In and poles matter most.

    Can I use a DC fuse instead of a breaker?

    Yes. A gPV fuse with a holder provides equivalent string protection, but a DC isolator will additionally be needed for isolation. A breaker combines both functions.

    Is a 2P breaker suitable for a 1000 V string?

    Yes, if its Ue = 1000 V DC for two-pole connection. Some manufacturers specify 1000 V only for 4 poles connected in series – see the product description.

    10. Other related guides

    The information in this guide is for guidance only. The final decision is made by the designer or electrician according to the equipment manufacturer's documentation and applicable requirements (IEC 62548, IEC 60364-7-712). UAB „Elektrotechnikos sprendimai“ is not liable for selections made solely on the basis of this guide.

    Published: 2026-11-17 · Data verified against IEC 62548: 2026-11-17

    Read more
    Modular DC protective circuit breaker for solar modules | 2P | 20A | 1000VDC | 6kA | DIN | ES-TXL7-20PV
    Code: ES-TXL7-20PV

    DC circuit breaker – a professional solution designed for the protection of direct current (DC) distribution networks and solar (PV) systems. It reliably protects circuits from overloads and short circuits, helping to prevent equipment damage or fire risk. Suitable for both residential users and industrial projects. The 2-pole model supports up to 1000V DC voltage with a breaking capacity of 6kA – ensuring a high level of protection even during sudden current surges.

    Price 25.11 € VAT incl.
    ( 20.75 € VAT excl. )
    Modular DC protective circuit breaker for solar modules | 2P | 20A | 1000VDC | 6kA | DIN | ES-TXBD1-20
    Code: ES-TXBD1-20

    The DC circuit breaker is designed for the protection of solar power systems (PV systems) and direct current (DC) distribution systems. It effectively protects against short circuits and overloads in both industrial and residential solar installations. The device features a high breaking capacity – up to 6kA – making it a reliable choice for PV module systems, control circuits, or batteries, ensuring precise and rapid protection against overloads and short circuits.

    Price 24.18 € VAT incl.
    ( 19.98 € VAT excl. )
    Modular DC protective circuit breaker for solar modules | 2P | 16A | 1000VDC | 6kA | DIN | ES-TXBD1-16
    Code: ES-TXBD1-16

    The DC circuit breaker is designed for the protection of solar power systems (PV systems) and direct current (DC) distribution systems. It effectively protects against short circuits and overloads in both industrial and residential solar installations. The device features a high breaking capacity – up to 6kA – making it a reliable choice for PV module systems, control circuits, or batteries, ensuring precise and rapid protection against overloads and short circuits.

    Price 23.30 € VAT incl.
    ( 19.26 € VAT excl. )
    Modular DC protective circuit breaker for solar modules | 2P | 16A | 500VDC | DIN | TAIXI | E2P-DC500V-16A
    Code: E2P-DC500V-16A

    This miniature circuit breaker (MCB) is designed for use in solar energy systems where reliable direct current (DC) circuit protection is required. It protects photovoltaic (PV) circuits from overloads and short circuits. Ideally suited for use in solar power plants, inverter systems, and other direct current (DC) installations.

    Price 22.29 € VAT incl.
    ( 18.42 € VAT excl. )
    Modular DC protective circuit breaker for solar modules | 2P | 16A | 1000VDC | DIN | TAIXI | E2P-DC1000V-16A
    Code: E2P-DC1000V-16A

    This miniature circuit breaker (MCB) is designed for use in solar energy systems where reliable DC circuit protection is required. It protects photovoltaic (PV) circuits from overloads and short circuits. Ideally suited for use in solar power plants, inverter systems, and other direct current (DC) installations.

    Price 23.86 € VAT incl.
    ( 19.72 € VAT excl. )
    Modular DC protective circuit breaker for solar modules | 2P | 20A | 1000VDC | DIN | TAIXI | E2P-DC1000V-20A
    Code: E2P-DC1000V-20A

    This miniature circuit breaker (MCB) is designed for use in solar energy systems where reliable direct current (DC) circuit protection is required. It protects photovoltaic (PV) circuits from overloads and short circuits. Ideally suited for use in solar power plants, inverter systems, and other direct current (DC) installations.

    Price 24.05 € VAT incl.
    ( 19.88 € VAT excl. )
    Modular DC miniature circuit breaker for solar PV | 2P | 25A | 1000VDC | 6kA | C | DIN | Elsp Group | ES-TXL7-25PV
    Code: ES-TXL7-25PV

    Two-pole DC circuit breaker for PV strings and battery circuits: 25 A, C characteristic, up to 1000 V DC, Icu 6 kA, 2 DIN modules. Protects against overload and short circuit and breaks “+” and “−” simultaneously.

    Price 25.56 € VAT incl.
    ( 21.13 € VAT excl. )
    Modular DC circuit breaker for solar modules | 2P | 32 A | 1000 V DC | DIN | TAIXI E2P-DC1000V-32A
    Code: E2P-DC1000V-32A

    E2P-DC1000V-32A is a double-pole modular DC circuit breaker, 32 A, 1000 V DC, DIN-rail mounted. Designed for DC-side protection of solar (PV) power plants – connected between the solar module string and the inverter or string combiner box, protecting conductors and equipment from overload and short circuit.

    Price 25.80 € VAT incl.
    ( 21.32 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 125A | 1000VDC | 50kA
    Code: ES-TXBD2-125/PV

    A high-class molded case circuit breaker (MCCB) designed for use in direct current (DC) circuits where reliable protection against overloads and short circuits is required. This breaker is especially suitable for solar photovoltaic (PV) systems, wind power, hydropower, and other low-voltage DC energy distribution systems operating up to 1000V DC.

    With a high breaking capacity of up to 50 kA and reliable performance under harsh conditions, this breaker protects components of solar power plants or battery systems. 

    Price 60.14 € VAT incl.
    ( 49.70 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 125A | 600VDC | 50kA
    Code: ES-TXBD1-PV125

    The two-pole DC MCCB circuit breaker is designed to protect direct current (DC) circuits from overload and short circuits, and also functions as an isolator. It is ideally suited for use in photovoltaic (PV) systems, wind and hydroelectric power plants, and electric vehicle charging systems.

    High breaking capacity – Icu 50 kA (maximum breaking capacity) and Ics 35 kA (service breaking capacity) ensure reliable protection even under demanding conditions. A robust housing and compliance with international standards make it a reliable choice for professional installers. 

    Price 59.53 € VAT incl.
    ( 49.20 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 100A | 600VDC | 50kA
    Code: ES-TXBD1-PV100

    The two-pole DC MCCB circuit breaker is designed to protect direct current (DC) circuits from overload and short circuits, and also functions as an isolator. It is ideally suited for use in photovoltaic (PV) systems, wind and hydroelectric power plants, and electric vehicle charging systems.

    High breaking capacity – Icu 50 kA (maximum breaking capacity) and Ics 35 kA (service breaking capacity) ensure reliable protection even under demanding conditions. A robust housing and compliance with international standards make it a reliable choice for professional installers. 

    Price 56.14 € VAT incl.
    ( 46.40 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 80A | 600VDC | 50kA
    Code: ES-TXBD1-PV080

    The two-pole DC MCCB circuit breaker is designed to protect direct current (DC) circuits from overload and short circuits, and also functions as an isolator. It is ideally suited for use in photovoltaic (PV) systems, wind and hydroelectric power plants, and electric vehicle charging systems.

    High breaking capacity – Icu 50 kA (maximum breaking capacity) and Ics 35 kA (service breaking capacity) ensure reliable protection even under demanding conditions. A robust housing and compliance with international standards make it a reliable choice for professional installers. 

    Price 52.39 € VAT incl.
    ( 43.30 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 250A | 600VDC | 50kA
    Code: ES-TXBD1-250

    The two-pole DC MCCB circuit breaker is designed to protect direct current (DC) circuits from overload and short circuits, and also functions as an isolator. It is ideally suited for use in photovoltaic (PV) systems, wind and hydroelectric power plants, and electric vehicle charging systems.

    High breaking capacity – Icu 50 kA (maximum breaking capacity) and Ics 35 kA (service breaking capacity) ensure reliable protection even under demanding conditions. A robust housing and compliance with international standards make it a reliable choice for professional installers. 

    Price 73.75 € VAT incl.
    ( 60.95 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 200A | 600VDC | 50kA
    Code: ES-TXBD1-200

    The two-pole DC MCCB circuit breaker is designed to protect direct current (DC) circuits from overload and short circuits, and also functions as an isolator. It is ideally suited for use in photovoltaic (PV) systems, wind and hydroelectric power plants, and electric vehicle charging systems.

    High breaking capacity – Icu 50 kA (maximum breaking capacity) and Ics 35 kA (service breaking capacity) ensure reliable protection even under demanding conditions. A robust housing and compliance with international standards make it a reliable choice for professional installers. 

    Price 69.58 € VAT incl.
    ( 57.50 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 160A | 600VDC | 50kA
    Code: ES-TXBD1-160

    The two-pole DC MCCB circuit breaker is designed to protect direct current (DC) circuits from overload and short circuits, and also functions as an isolator. It is ideally suited for use in photovoltaic (PV) systems, wind and hydroelectric power plants, and electric vehicle charging systems.

    High breaking capacity – Icu 50 kA (maximum breaking capacity) and Ics 35 kA (service breaking capacity) ensure reliable protection even under demanding conditions. A robust housing and compliance with international standards make it a reliable choice for professional installers. 

    Price 66.79 € VAT incl.
    ( 55.20 € VAT excl. )
    Industrial protective DC circuit breaker for solar modules 2P | 150A | 600VDC | 50kA
    Code: ES-TXBD1-150

    The two-pole DC MCCB circuit breaker is designed to protect direct current (DC) circuits from overload and short circuits, and also functions as an isolator. It is ideally suited for use in photovoltaic (PV) systems, wind and hydroelectric power plants, and electric vehicle charging systems.

    High breaking capacity – Icu 50 kA (maximum breaking capacity) and Ics 35 kA (service breaking capacity) ensure reliable protection even under demanding conditions. A robust housing and compliance with international standards make it a reliable choice for professional installers. 

    Price 62.62 € VAT incl.
    ( 51.75 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 40A | 1000VDC | 6kA | DIN
    Code: ES-TXL7-40PV

    DC circuit breaker – a professional solution designed for the protection of direct current (DC) distribution networks and solar (PV) systems. It reliably protects circuits from overloads and short circuits, helping to prevent equipment damage or fire risk. Suitable for both residential users and industrial projects. The 2-pole model supports up to 1000V DC voltage with a breaking capacity of 6kA – ensuring a high level of protection even during sudden current surges.

    Price 27.23 € VAT incl.
    ( 22.50 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 16A | 1000VDC | 6kA | DIN
    Code: ES-TXL7-16PV

    DC circuit breaker – a professional solution designed for the protection of direct current (DC) distribution networks and solar (PV) systems. It reliably protects circuits from overloads and short circuits, helping to prevent equipment damage or fire risk. Suitable for both residential users and industrial projects. The 2-pole model supports up to 1000V DC voltage with a breaking capacity of 6kA – ensuring a high level of protection even during sudden current surges.

    Price 24.59 € VAT incl.
    ( 20.33 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 10A | 1000VDC | 6kA | DIN
    Code: ES-TXL7-10PV

    DC circuit breaker – a professional solution designed for the protection of direct current (DC) distribution networks and solar (PV) systems. It reliably protects circuits from overloads and short circuits, helping to prevent equipment damage or fire risk. Suitable for both residential users and industrial projects. The 2-pole model supports up to 1000V DC voltage with a breaking capacity of 6kA – ensuring a high level of protection even during sudden current surges.

    Price 24.20 € VAT incl.
    ( 20.00 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 50A | 1000VDC | 6kA | DIN
    Code: ES-TXBD1-50

    The DC circuit breaker is designed for the protection of solar power systems (PV systems) and direct current (DC) distribution systems. It effectively protects against short circuits and overloads in both industrial and residential solar installations. The device features a high breaking capacity – up to 6kA – making it a reliable choice for PV module systems, control circuits, or batteries, ensuring precise and rapid protection against overloads and short circuits.

    Price 27.44 € VAT incl.
    ( 22.68 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 40A | 1000VDC | 6kA | DIN
    Code: ES-TXBD1-40

    The DC circuit breaker is designed for the protection of solar power systems (PV systems) and direct current (DC) distribution systems. It effectively protects against short circuits and overloads in both industrial and residential solar installations. The device features a high breaking capacity – up to 6kA – making it a reliable choice for PV module systems, control circuits, or batteries, ensuring precise and rapid protection against overloads and short circuits.

    Price 26.14 € VAT incl.
    ( 21.60 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 25A | 1000VDC | 6kA | DIN
    Code: ES-TXBD1-25

    The DC circuit breaker is designed for the protection of solar power systems (PV systems) and direct current (DC) distribution systems. It effectively protects against short circuits and overloads in both industrial and residential solar installations. The device features a high breaking capacity – up to 6kA – making it a reliable choice for PV module systems, control circuits, or batteries, ensuring precise and rapid protection against overloads and short circuits.

    Price 24.61 € VAT incl.
    ( 20.34 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 10A | 1000VDC | 6kA | DIN
    Code: ES-TXBD1-10

    The DC circuit breaker is designed for the protection of solar power systems (PV systems) and direct current (DC) distribution systems. It effectively protects against short circuits and overloads in both industrial and residential solar installations. The device features a high breaking capacity – up to 6kA – making it a reliable choice for PV module systems, control circuits, or batteries, ensuring precise and rapid protection against overloads and short circuits.

    Price 22.65 € VAT incl.
    ( 18.72 € VAT excl. )
    Modular protective DC circuit breaker for solar modules 2P | 6A | 1000VDC | 6kA | DIN
    Code: ES-TXBD1-06

    The DC circuit breaker is designed for the protection of solar power plants (PV systems) and direct current (DC) distribution systems. It provides effective protection against short circuits and overloads in both professional industrial and household solar installations. The device features a high breaking capacity – up to 6kA – making it a reliable choice for low-power circuits, such as PV module sections, control circuits, or low-capacity batteries, ensuring precise and fast protection against overloads and short circuits.