Electrical distribution boards, enclosures and accessories
The distribution board is the heart of the installation: circuit breakers, residual current protection, the meter and control devices all come together here. This group includes surface-mounted, flush-mounted, apartment-building, construction-site and special boards, switch cabinets and all accessories for assembly. Selection starts with three parameters: supply type (1F / 3F), number of modules and IP rating.
Key idea:
A wrongly chosen board – too small, with the wrong IP rating or single-phase where three-phase is needed – leads to overcrowded enclosures, faults and fire risk. A suitable board with a 30 % module reserve lets you add new circuits later (heating, an EV charger, a solar plant) without replacing the board itself.
Supply type
Single-phase (1F) or three-phase (3F) – everything depends on it
Number of modules
Count the components + 30 % reserve
IP rating
IP40 – dry room; IP44+ – bathrooms, basements, garages; IP65+ – outdoors
Mounting type
Surface – quick; flush – aesthetics; floor-standing – industry
In this group
|
Surface-mounted boards and enclosures |
Renovation, basement, garage, industrial premises – installation without chasing walls |
|
Flush-mounted boards and enclosures |
New build, living rooms – aesthetics; the recess requires a minimum wall depth |
|
Metering boards for apartment buildings |
Staircases and common areas – house meters and protective devices for several apartments |
|
Portable construction-site boards |
Construction site, temporary supply – IP54–IP55, cable strain-relief clamps |
|
Special boards |
Garages, commercial premises, outdoor installation – compact solutions for specific environments |
|
Switch cabinets |
Industry, server and network equipment – large depths, adjustable rails, high IP |
|
Accessories (DIN, terminals, locks) |
For board assembly – rails, N/PE busbars, fixings, locks |
How to choose: 3 steps
Step 1 – Determine the supply type. Look at the meter or the supply cable: single-phase supply (1F) – 2 wires or a 1F meter; three-phase (3F) – 4 wires or a 3F meter. This determines the board type, the choice of breakers and the whole installation diagram.
Step 2 – Count the modules. Each component takes space on the DIN rail (17.5 mm width per module): circuit breaker 1P – 1 mod.; 2P – 2 mod.; RCD 2P – 2–4 mod.; RCBO – 2 mod.; meter – 4–9 mod. Add up all components and add a 30 % reserve.
Step 3 – Choose the IP rating according to the room type.
|
IP40 |
Dry room – living room, office, technical room |
Not for bathrooms, garages or outdoors |
|
IP44 |
Bathroom zone 2, basements, garages |
Not for direct rain |
|
IP54–55 |
Garages, warehouses, construction sites |
Not for long-term immersion |
|
IP65–66 |
Outdoor installation, car washes, aggressive environment |
— |
A common mistake – a single-phase board in a three-phase system:
Breakers trip for no reason, cables overheat. Before buying, check the meter's technical data – it states the supply type.
Where is it used?
-
Private houses and cottages – main distribution board for a single-phase or three-phase system
-
Apartments – compact flush-mounted board with an RCD and an RCBO for each circuit
-
Garages and basements – surface-mounted IP44 board, moisture-resistant
-
Industrial and commercial premises – switch cabinets with a large number of modules
-
Construction sites – portable construction-site board with IP54 and cable clamps
-
Apartment-building staircases – special metering boards with meter compartments
-
Outdoor installation – IP65+ boards for sun, rain and temperature changes
-
Server and network rooms – switch cabinets with adjustable ventilation and locks
Use by need
For the electrician / installer.
Exact dimensions, IP rating, number of DIN rails and module capacity – everything needed to specify and install correctly.
For the home owner / builder.
Simple criteria (1F or 3F, whether a reserve is needed, what kind of room) help to choose the right board without mistakes that are expensive to fix later.
For the designer / contractor.
Full documentation – standards, dimensions, mounting type – lets you include the board in the design with exact parameters.
What buyers value
-
Wide choice from 4 to 72+ modules
-
IP40–IP66 – for every environment
-
Surface- and flush-mounted models
-
Accessories in the same place – DIN, busbars, locks
-
Technically accurate descriptions with dimensions and drawings
What to check before buying
-
Scope of delivery: DIN rail, N and PE busbars are often supplied separately
-
Cable entry opening: thick cables must fit – check the dimensions
-
A flush-mounted board requires a minimum wall depth – check before cutting
-
Colour: some models are grey only – check if it matters
-
In a bathroom (zones 1–2) the IP rating must be at least IP44 – a requirement of HD 60364
-
Connection to the supply must be made by a qualified, certified electrician – a requirement of national regulations
-
A board with exposed wires and no cover – risk of electric shock; use only with the cover closed
-
Do not install a higher load than stated in the board specification
Quick selection guide
1F supply
Single-phase boards with 1P or 1P+N breakers
3F supply
Three-phase boards with 3P or 4P breakers
Apartment / room
Flush-mounted IP40, 12–24 mod.
House with heating
36–48 mod. (+ EV or solar: 54–72 mod.)
Suitable when you need:
-
A new installation or a renovation
-
A board with a reserve for an EV charger or solar panels
-
An IP44+ solution for damp or outdoor environments
Check before buying:
-
Supply type – 1F or 3F (from the meter's technical data)
-
Cable cross-section – will it fit the board's entry opening
-
Wall depth – for flush-mounted models
Important reminder: A board does not replace a certified electrician – connection to the supply must be made by a specialist.
Frequently asked questions
Can I install the board myself?
The board may be installed by a person with an electrician's qualification; connection to the supply must be made by a certified electrician.
What is the difference between an RCD and an RCBO?
An RCD protects several circuits at once – when it trips, the whole group is switched off; an RCBO is an RCD and a circuit breaker in one, it protects an individual circuit and a fault does not switch off the others.
Is the board sold with a DIN rail and busbars?
Not always – check the scope of delivery of the specific product; DIN rails, N and PE busbars can be found in the accessories section.
How many modules does a private house need?
With heating, a cooker, a water heater and a garage – 36–48 mod.; with an EV charger or solar panels – 54–72 mod.
What IP rating is needed in a bathroom?
Zones 1–2 – at least IP44; this is set in the HD 60364 standard.
How to choose terminals for the board?
The rated current of the terminal must be at least the circuit current and match the cable cross-section. Example rated currents of modular terminals according to IEC 60947-7-1: 2.5 mm² – 24 A; 4 mm² – 32 A; 6 mm² – 41 A. The exact value is in the data of the specific terminal.
Electrical distribution boards, enclosures and accessories
A full range of boards and enclosures for domestic and industrial installations – from a compact 12-module flush-mounted board to an IP66 outdoor cabinet. Not sure where to start? Send us the supply type (1F/3F), the room and the planned number of circuits – we will give you a specific answer.