Guide to locks, latches and keys for electrical panels: how to identify, choose and install
Here you will find quick selection by situation, how to identify key types, how to choose a cam lock by door thickness, a comparison matrix of all types, an overview of electronic locks, the most common mistakes and answers to practical questions. Exact dimensions and parameters are given in each product description.
Colour meanings: ■ information · ■ benefit, solution · ■ ⚠ check · ■ ⚡ safety, mistakes
What do you need? Quick selection
|
Situation |
Solution |
Where to look |
|
Electricity meter panel or cabinet for a house or stairwell |
Triangle key lock (most often T10, M24 thread, 48 mm long) or a lock with a padlock hasp |
Technical key locks, with hasp |
|
KS transit cable cabinet |
Half-moon lock and half-moon (D-shaped) key – the standard for transit cabinets in Lithuania |
Half-moon lock, key |
|
Substation, distribution point |
SP-1 padlock with a threaded key: left-hand thread (SP-1) or right-hand thread (SP-1D) |
SP-1 padlock, SP-1 key |
|
Distribution or automation panel indoors |
Cam lock with a cylinder key – cylinder length to suit the door thickness, can be keyed alike for several panels |
Cam locks |
|
Outdoor control cabinet, dust and moisture |
Compression latch with handle or a lock with a protective cover |
Handles and compression latches, with cover |
|
Tall cabinet doors that need locking at several points |
Handle with a rod system – the door is locked at the top and bottom in one movement |
Rod locks |
|
Many sites, need to know who opened what and when |
Electronic locks with an AES256 key, no battery in the lock, with an access log |
Electronic locks |
|
Repairs, temporary locking, LOTO |
Cable padlocks or safety padlocks and LOTO equipment |
Padlocks, LOTO |
|
Need to open a panel, no key |
Triangle keys 8.5, 9 and 10 mm or a universal cross key for electricians |
Panel keys, universal keys |
Key types: how to identify an existing lock
Before buying a new lock or key, look at the head of the existing lock. Measure technical keys with a caliper – you cannot tell a 9 mm triangle from a 10 mm one by eye.
|
Key type |
How to identify |
Where it is used |
Protection |
What to buy |
|
Triangle |
Triangular pin in the lock head, usually 8, 8.5, 9 or 10 mm |
Meter panels and cabinets, automation boxes |
Against accidental opening, not against theft |
8.5 mm, 9 mm, 10 mm |
|
Cross, square, double-bit |
Cross, square or double-bit profile |
Panels, ventilation and building services boxes |
Against accidental opening |
Universal cross keys |
|
Half-moon (D shape) |
Semicircular spindle onto which a socket key is fitted |
KS transit cable cabinets in Lithuania |
Limited, standard grid key |
Half-moon key |
|
Hexagon, U-shaped |
Hexagonal or U-profile pin |
Meter cabinets, stainless steel enclosures |
Medium – a less common tool |
Technical key locks |
|
SP-1 threaded key |
The key screws onto the lock body; left-hand thread (SP-1) or right-hand thread (SP-1D) |
Substations, distribution points |
Medium, sites are grouped by thread direction |
SP-1, SP-1D |
|
Cylinder (cam lock) |
Keyway in the cylinder, key with cuts |
Distribution and automation panels, IT cabinets |
Medium to high, depends on the grade |
Cam locks |
|
Electronic key |
Contact head instead of a keyway |
Grid, telecom and industrial sites |
High, with an access log |
Electronic locks |
Triangle and cross keys are technical locks: they keep casual passers-by out of the panel, but anyone can buy such a key. If you need protection against theft or vandalism, choose a cylinder or electronic lock, or a lock with a padlock hasp.
How to choose a cam lock: 4 steps
1. Cylinder length
By door thickness: the cylinder must pass through the door and still leave room for the nut and the cam
2. Cam
Straight, cranked or hooked – depending on the distance to the panel frame
3. Rotation angle
90° or 180° and the direction of rotation
4. Keys and grade
How many keys, whether several panels need to be keyed alike, ANSI Grade 1 or 2
The cylinder length is measured from the underside of the flange (head) to the end of the thread. Measure the door thickness including any gasket or reinforcement and compare it with the suitable thickness given by the manufacturer in the product description. We stock cylinders from 10 to 62 mm:
■ ANSI Grade 1 and 2
-
Security grades under the ANSI/BHMA A156.11 standard for cabinet locks.
-
Grade 1 is the highest grade: it withstands more cycles, greater force and higher torque.
-
Grade 2 is sufficient for most indoor distribution and control cabinets.
-
The grade indicates mechanical durability, not resistance to outdoor conditions.
■ One key for several panels
-
“Keyed alike” means several locks open with the same key.
-
Convenient when a site has many panels serviced by the same electrician.
-
When ordering, state the number of locks and that they must be keyed alike.
-
If a key is lost, the whole set has to be replaced, so keep spare keys separately.
Comparison matrix: all types in the group
Indicative prices incl. VAT based on catalogue data as of 2026-10-25; the current price is shown on the product page. Stars show the relative level of protection against unauthorised opening.
|
Type |
Key |
Protection |
Environment |
Price |
Best for |
|
Technical key locks |
Triangle, cross, hexagon, U, half-moon |
★ |
Indoor; IP54 models available |
3.59–14.59 € |
Meter panels, transit cabinets |
|
Cam locks |
Cylinder, 2 keys |
★★–★★★ |
Indoor; IP54 models available |
4.32–11.86 € |
Distribution, automation, IT cabinets |
|
Locks with handle or cover |
Cylinder, triangle or keyless |
★–★★ |
The cover protects against dust |
2.95–16.63 € |
Panels opened frequently by staff |
|
Handles and compression latches |
Cylinder, 2 keys |
★★★ |
Compression seals the door |
5.76–37.68 € |
Industrial, outdoor and control cabinets |
|
Rod locks |
Key, stainless steel |
★★★ |
Outdoor and indoor |
54.89 € |
Tall cabinet doors, multi-point locking |
|
Locks with padlock hasp |
Push-button, 9 mm hole for a padlock |
★★★ with padlock |
Indoor and outdoor under a canopy |
22.14 € |
Panels that need additional locking |
|
SP-1 padlocks and cable locks |
Threaded key, combination |
★★ |
Outdoor |
4.26–9.56 € |
Substations, temporary locking |
|
Electronic and smart locks |
Electronic key, AES256 |
★★★★ |
IP66 |
53.76–141.06 € |
Grid, telecom, industrial sites |
The table compares types, not the properties of specific models. IP rating, door thickness and mounting cut-out are given in each product description.
Electronic locks: how they work and when they pay off
■ How they work
-
Passive system: there is no battery in the lock – power and data are supplied by the electronic key.
-
Communication between the key and the lock is encrypted with AES256.
-
The system records who opened which lock and when; access rights can be limited by time.
-
If a key is lost, it is disabled in the system – no locks need to be replaced.
■ When they pay off
-
Many remote sites: transformer substations, telecom and control cabinets.
-
Several contractors service the site and need temporary access.
-
Access control and audits are required.
-
Managing mechanical keys and replacing locks costs more than the system.
Some electronic locks are sold without a key – they are intended for extending an existing access control system. Before ordering, check that the lock is compatible with your keys and software.
⚠ What to check before buying
KibirkštisThe first time I bought a lock from a photo, it did not fit the door. Now I always check these things before ordering.
|
What to check |
Why it matters |
|
Key type and size |
8, 9 and 10 mm triangles look alike, but the keys are not interchangeable. Measure with a caliper. |
|
Door thickness and cylinder length |
If the cylinder is too short, the nut will not fit; if it is too long, the cam will not reach the frame or will catch on equipment. |
|
Mounting cut-out |
The cut-out may be round, D-cut or rectangular (for handles, e.g. 35 × 90 mm). Compare it with the product drawing. |
|
Rotation angle and direction |
90° or 180°, left or right – this determines whether the cam engages the frame. |
|
Environment and IP rating |
Outdoors or in damp rooms choose a lock with a cover, a compression latch or an IP66 lock; indoor locks freeze and rust. |
|
Who owns the panel |
Locks and seals on the grid operator ESO's meter and transit cabinets must not be changed without authorisation – agree it with the grid operator. |
✗ Most common mistakes
|
Mistake |
Consequence |
|
Lock bought from a photo without measuring the cylinder |
It does not fit the door or the cam does not reach the frame – it has to be returned or replaced. |
|
9 and 10 mm triangles mixed up |
The key slips and wears down the lock pin. |
|
SP-1 key with the wrong thread direction |
A left-hand thread padlock cannot be opened with a right-hand thread key (SP-1D), and vice versa. |
|
Triangle lock where protection against theft is needed |
Anyone with a universal key can open the panel. |
|
Indoor cam lock on an outdoor cabinet without a cover |
Water and frost jam the cylinder and the lock rusts. |
|
Lock on an ESO cabinet replaced or a seal removed without authorisation |
The grid operator may treat this as a violation. |
⚡ Safe installation – advice from Fazė
-
Replace the lock with the door removed or the panel de-energised – do not work near exposed live parts.
-
When drilling or enlarging the hole, metal swarf must not get into the panel – cover the equipment and clean up afterwards.
-
After the work, restore the door's protective earth (PE) connection if you disconnected it.
-
A panel with live parts must be lockable so that unauthorised persons cannot open it.
-
Lock out the circuit under repair with a LOTO padlock and attach a tag.
-
Work inside the panel must be carried out by a qualified electrician.
Frequently asked questions
The questions are asked by Kibirkštis – a young, curious electrician who dares to ask what others won't. The answers come from Fazė – an experienced engineer.
KibirkštisHow do I find out what size triangle key I need?
FazėMeasure the triangular pin of the lock with a caliper. The most common sizes are 8, 8.5, 9 and 10 mm; meter cabinets in Lithuania often use 10 mm (T10). If in doubt, send us a photo with a ruler next to the lock.
KibirkštisCan I replace the lock on an electricity meter panel myself?
FazėOn your own panel – yes, if the work is done by a qualified electrician. If the cabinet contains an ESO meter, has seals or belongs to the grid operator, agree the lock replacement with the grid operator ESO first.
KibirkštisWhat length of cam lock does my panel need?
FazėMeasure the door thickness where the hole will be, including any gasket or reinforcement. The cylinder must be longer than the door thickness by enough to fit the nut and the cam. You will find the suitable thickness range in the product description; if the thickness is at the limit, choose a longer cylinder and adjust the position of the cam.
KibirkštisWhat is the difference between SP-1 and SP-1D keys?
FazėThe thread direction. An SP-1 padlock opens with a left-hand thread key, SP-1D with a right-hand thread key. The keys are not interchangeable, so operators use the thread direction to divide sites into groups. The padlock is sold without a key – order the key separately.
KibirkštisWhat does ANSI Grade 1 mean in a lock description?
FazėIt is the highest grade for cabinet locks under ANSI/BHMA A156.11: the lock is tested with more cycles, greater force and higher torque than Grade 2. It indicates mechanical durability, not resistance to moisture – outdoors you still need a cover or IP protection.
KibirkštisDoes an electronic lock need batteries or wiring?
FazėThe passive electronic locks we offer have no battery – power is supplied by the electronic key when it is held against the lock. No wiring is needed, and the battery is only replaced in the key.
KibirkštisCan you supply locks keyed alike for several panels?
FazėYes. Send us the number of panels, the door thickness, the cut-out dimensions and a photo of the existing lock – we will select keyed-alike locks and send you an offer.
Contact us.
⚠ This guide is for reference only
The information and selection advice in this guide are indicative and may contain inaccuracies. They do not replace the manufacturer's instructions, applicable legislation or the grid operator's requirements. Before purchase and installation, check the dimensions and parameters in the specific product description and the manufacturer's datasheet.
Responsibility for selecting and installing the lock and for the security of the panel lies with the qualified electrician carrying out the work or the owner of the site. UAB „Elektrotechnikos sprendimai“ accepts no responsibility for the selection of products based on this guide, for installation, for possible errors or for unauthorised access to panels.
Sources
Standards and data on which this guide is based. Checked 2026-10-25.
-
ANSI/BHMA A156.11 – Cabinet Locks (security grades for cabinet locks)
-
EN IEC 61439-1 – Low-voltage switchgear and controlgear assemblies. Part 1: General rules
-
EN 60529 – Degrees of protection provided by enclosures (IP Code)
-
EN 12320 – Building hardware. Padlocks and padlock fittings
-
Manufacturers' technical data given in the product descriptions on elsprendimai.eu
Locks, keys and panels – in a single order
We select locks to suit the existing cut-out and door thickness, keys to suit the lock type, keyed-alike sets for sites and electronic locks for grid infrastructure. Send us a photo, the dimensions or a list – we will send you an offer. The model you need is not in the catalogue? Some products are supplied to order.
Get an offer