Work safety – equipment selection guide
The main hazards when working with electrical equipment are ⚡ electric shock, arc flash and unexpected start-up of equipment. Below: what to choose for each task, kit levels from a single electrician to a whole company, the safe isolation sequence with LOTO, dielectric equipment classes, work zone protection and the most common mistakes.
Colour key: ■ information · ■ what protects · ■ ⚠ LOTO and verification · ■ ⚡ voltage and danger · ■ machine safety
This guide is for information only. UAB „Elektrotechnikos sprendimai“ accepts no responsibility for product selection based solely on this guide – make the final decision after checking the product description, your company's risk assessment and safety instructions, or after consulting us.
What to choose for the task
|
Task or risk |
Equipment |
Where to look |
|
Equipment isolated for repair or maintenance |
⚠ Personal LOTO padlock and tag “Do not switch on! Work in progress” |
LOTO safety padlocks, LOTO tags |
|
You need to lock a circuit breaker, knife switch or STOP button |
⚠ Breaker or button lockout + padlock |
Breaker and button lockouts |
|
You need to lock out a plug, valve or gas cylinder |
⚠ Plug cover, valve lockout |
Plug lockouts, Valve lockouts |
|
Several workers service the same equipment |
⚠ Lockout hasp, group lock box |
Lockout hasps, Key boxes and padlock stations |
|
Everything at once – for a new team or site |
⚠ Complete LOTO kit in a case |
LOTO kits |
|
⚡ You need to verify absence of voltage |
Contact voltage indicator rated for the network voltage |
Voltage indicator 0.4 kV, High-voltage indicator 10 kV |
|
⚡ Work in a panel or near live parts |
Dielectric gloves, mat, boots |
Gloves, Mats, Boots |
|
⚡ You need to cover adjacent live parts or protect your arms |
Insulating covers and sleeves |
Insulating covers and sleeves |
|
⚡ Switching operations at higher voltage |
Insulating operating stick |
Insulating sticks |
|
Work at height near electrical installations |
Dielectric ladder or insulated platform |
Dielectric ladders |
|
Climbing poles, work at height |
Safety belt, pole climbers, helmet |
Work at height, Helmets and glasses |
|
Installation, cable preparation and lug crimping |
Insulated and special tools |
Pliers, Screwdrivers, Stripping, Crimping tools |
|
Everyday protection against mechanical injury |
Work gloves, safety shoes, glasses |
Work gloves, Safety shoes, Glasses and helmets |
|
Fencing off the work zone, sharp corners, low beams |
Barriers, protective corner guards |
Barriers and impact protection |
|
You need audible and visual hazard warning |
Alarm siren, audible–visual signal |
Alarm sirens |
|
Filling station, fuel depot, gas or chemical site |
Static discharge post |
Antistatic protection |
|
Machine emergency stop, guard doors |
Safety relay |
Safety relays |
|
Storing and transporting tools and equipment |
Boxes, cases, bags |
Transport cases |
⚡ A STOP or emergency stop button is not an energy isolating device. A STOP button lock prevents the button from being reset or pressed, but does not disconnect the voltage. Apply LOTO to the main switch or another energy isolating device according to the workplace procedure, and use the STOP lock as an additional measure.
Where an arc flash risk has been identified, protective clothing and face protection are selected based on the risk assessment. Check clothing compliance with IEC 61482-2 and the required protection level in the manufacturer's documents; dielectric gloves or a mat do not replace this protection.
KibirkštisI locked the STOP button with a LOTO lock – so I can reach into the machine?
FazėNo. The STOP button stops motion through the control circuit, but power stays on. First isolate and lock the main switch – that's what
breaker lockouts are for. The STOP lock is extra protection so nobody resets the button while you work.
Kit levels: from a single electrician to a whole company
Each level includes the previous one. Start from your situation and add only what is missing.
Level 1. Electrician up to 1 kV
Flats, houses, commercial sites, panels up to 1 kV
Level 2. Crew, maintenance team
Several workers on the same equipment
Level 3. Substations and higher voltage
Power engineers, transformer substations and switchgear maintenance
Level 4. Factory and machine safety
Production lines, warehouses, hazardous zones
⚠ Safe isolation sequence and LOTO
In Lithuania, the Safety Rules for Operating Electrical Installations (item 80) set a mandatory sequence before work on de-energised equipment; in other countries apply national requirements. LOTO (Lockout / Tagout) devices cover steps 3–4 – ensuring the equipment cannot be switched on while work is in progress.
|
Step |
What to do |
Equipment |
|
1 |
Switch off the voltage |
– |
|
2 |
Disconnect the equipment from all power sources |
– |
|
3 |
Prevent the equipment from switching on by itself or by mistake |
LOTO padlock, breaker lockout, plug lockout |
|
4 |
Hang the sign “Do not switch on! Work in progress” |
LOTO tag |
|
5 |
⚡ Verify absence of voltage, using a tested indicator designed for this purpose and checked before use. After the test, check its operation again according to the manufacturer's instructions |
Voltage indicator 0.4 kV, 10 kV |
|
6 |
Earth and mark as prescribed |
– |
|
7 |
Prepare the workplace and fence off adjacent live parts |
Workplace barriers, insulating covers |
ℹ Each worker locks their own padlock and keeps their own key. When several people work – use a lockout hasp: the equipment can only be switched on after all padlocks are removed.
⚡ A non-contact tester pen or wrist alarm does not prove absence of voltage. They are suitable for early warning. Verify absence of voltage with a contact indicator designed for the voltage of the network being tested – check suitability in the product card. All measuring equipment –
in the Measuring equipment group.
KibirkštisThree of us work on one panel. Is one padlock on the main switch enough?
FazėNo. One key – one person. Put a
lockout hasp on the switch, and everyone hangs their own padlock. Until the last person removes theirs, it cannot be switched on. For longer jobs keep the keys in a
group lock box.
⚡ Dielectric equipment – how to choose the class
Assess glove and mat classes separately according to their standard and marking. Maximum AC working voltages are given below; check DC limits in the manufacturer's documents. Choose the class based on the highest expected working voltage.
Dielectric gloves – IEC 60903
|
Class |
Maximum working voltage (AC) |
Typical use |
|
00 |
500 V |
Low-voltage control circuits |
|
0 |
1 000 V |
Distribution panels up to 1 kV |
|
1 |
7 500 V |
Medium voltage |
|
2 |
17 000 V |
Medium voltage |
|
3 |
26 500 V |
Medium voltage |
|
4 |
36 000 V |
Medium voltage |
Dielectric mats – IEC 61111
|
Class |
Maximum working voltage (AC) |
Typical use |
|
0 |
1 000 V |
Distribution panels up to 1 kV |
|
1 |
7 500 V |
Medium voltage |
|
2 |
17 000 V |
Medium voltage |
|
3 |
26 500 V |
Medium voltage |
|
4 |
36 000 V |
Medium voltage |
-
Inspect the gloves before each use and check them for leaks by inflating them with air.
-
Carry out periodic tests according to applicable requirements and the manufacturer's instructions; mark the test date on the item.
-
Store dry, away from direct sunlight, heat and sharp objects.
-
Check the class and voltage of a specific product in its product card.
Additional dielectric equipment: dielectric boots, insulating operating sticks, insulating covers and sleeves to cover adjacent live parts, and dielectric ladders and insulated platforms for work at height near electrical installations. Check the operating voltage and conditions in each product card.
Insulated tools
For work near live parts choose tools marked with the 1000 V symbol and double triangle (IEC 60900) – they are designed for work up to 1000 V AC / 1500 V DC; this is the working voltage, not the test voltage. Check the suitability of a specific tool in its marking and the manufacturer's instructions. This group also contains standard installation tools;
the category name alone does not confirm their suitability for live work. In the group:
insulated pliers,
screwdrivers,
cable cutters,
stripping tools,
crimping tools,
hydraulic hole punches.
Work zone, work at height and warning
|
Equipment |
Purpose |
⚠ What to watch out for |
|
Work zone barriers |
Marks and restricts access to the workplace or hazardous equipment |
A barrier is not insulation: cover live parts with insulating covers |
|
Protective corner guards |
Protects heads and equipment from impacts on sharp corners, beams, pipes |
Stuck onto a clean, dry surface; choose the profile (L, U, round) according to the corner shape |
|
Alarm sirens |
Audible and visual warning of danger, equipment start-up or evacuation |
The supply voltage (12/24 V DC, 230/400 V AC) must match the control circuit; a siren supplements but does not replace LOTO and emergency stop |
|
Antistatic discharge posts |
Discharging a person's static charge before entering an explosive zone, earthing vehicles during filling |
The post is connected to the site earthing system; check Ex zone suitability in the product card |
|
Safety belts |
Work positioning and protection during work at height |
A waist belt does not arrest a fall – a full body harness with a shock absorber is used for that. The right equipment is determined by the risk assessment |
|
Pole climbers |
Climbing reinforced concrete poles |
Use only on the pole type they are designed for, and together with a safety belt |
|
Glasses and helmets |
Eye protection from fragments, head protection from impacts |
For work on electrical installations choose a helmet without metal parts; assess arc risk separately |
Safety relays – machine safety
A safety relay monitors emergency stop buttons, guard doors or light curtains and safely disconnects hazardous motion. This is a different purpose from a voltage protection relay, which protects equipment from over- or undervoltage.
The safety function level (PL, SIL) and wiring diagram are selected according to the machine risk assessment and manufacturer documentation. More on buttons and contactors – in the Buttons guide and in the Contactors and relays guide.
✗ Most common mistakes
|
Mistake |
Consequence |
|
✗ Equipment isolated but not locked |
Another worker can switch it on |
|
✗ Several workers use one padlock |
Equipment is switched on while someone is still working |
|
✗ A locked STOP button is treated as isolation |
Power remains – risk of electric shock or unexpected start-up |
|
✗ ⚡ Absence of voltage not verified “because it's switched off” |
Backfeed or wrongly isolated line |
|
✗ ⚡ Absence of voltage checked with a non-contact pen |
The pen may not react even though voltage is present |
|
✗ Glove class chosen by the tool rather than the equipment voltage |
Insufficient insulation |
|
✗ Damaged or untested dielectric gloves |
Risk of electric shock |
|
✗ Ordinary tools for work near live parts |
Short circuit, arc flash |
|
✗ A barrier used instead of an insulating cover |
Accidental contact with live parts |
Frequently asked questions
KibirkštisHow does a LOTO padlock differ from an ordinary padlock?
FazėA LOTO padlock is designed to lock an energy isolating device and identify the worker. In a KD (keyed different) system each padlock has its own key; padlocks in a KA (keyed alike) set share one key and are assigned to one worker. Do not share one KA set between different workers. Check the insulating properties of the body and shackle in the specific model's
product card.
KibirkštisWhat glove class is needed for a panel up to 1 kV?
KibirkštisDoes a dielectric mat replace gloves?
FazėNo. The mat insulates from the floor, gloves insulate the hands. They are used together:
mats and
gloves.
KibirkštisI have a non-contact tester pen. Is it enough for step 5?
FazėNo. The pen is fine for a quick check, but it doesn't prove absence of voltage. Use a contact indicator designed for the network voltage, e.g. a
0.4 kV voltage indicator, and check its operation before and after the measurement.
KibirkštisHow does a safety relay differ from a voltage protection relay?
FazėA safety relay is for machine safety – emergency stop and guard doors. A voltage protection relay monitors the network voltage and protects equipment.
Safety relays here.
KibirkštisCan you put together a LOTO kit for a company?
FazėYes. Tell us what equipment needs locking out and how many people work – we will select padlocks, lockouts and tags. For smaller needs, consider ready-made
LOTO kits.
Contact us.
Related guides
Sources
Rules and standards used in this guide. Checked 2026-11-05.
-
Safety Rules for Operating Electrical Installations, Lithuania (e-seimas)
-
IEC 60903 – Live working. Gloves of insulating material
-
IEC 61111 – Live working. Electrical insulating matting
-
IEC 60900 – Live working. Hand tools for use up to 1000 V AC and 1500 V DC
-
IEC 61243 – Live working. Voltage detectors
-
IEC 61482-2 – Protective clothing against the thermal hazards of an electric arc
Safety equipment – in one order
Tell us the type of work, voltage level and number of workers – we will select LOTO, dielectric equipment, indicators and tools in one order. Model not in the catalogue? Some products are supplied to order.
Get a quote