Indoor lighting · recessed LED panels · ceiling installation
Recessed LED panels | lighting and installation selection guide
How to choose the right recessed LED panel according to room use, wattage, luminous flux, colour temperature, ceiling cut-out, recess depth, IP protection and electrical connection.
2700–4000 K
common colour options
Round / square
different panel shapes
Kibirkštis asks, Fazė answers – practical tips for choosing lighting.
Key point:
A recessed LED panel should be selected according to the room's illuminance requirement (lx), the luminaire's luminous flux (lm), electrical power (W), light colour (K) and the structural installation parameters. The same wattage does not necessarily mean the same amount of light, and the same outer dimensions do not necessarily mean the same cut-out.
Quick LED panel selection by room
The number and wattage of luminaires depend on the room's floor area, height, colours, windows, mounting geometry and the desired illuminance. The illuminance ranges below are indicative for initial planning; requirements for specific workplaces are checked according to the design.
|
Room |
Indicative illuminance |
Light colour |
Note |
|
Corridor |
100–150 lx |
2700–4000 K |
Uniformity and safe movement are important. |
|
Living room |
100–300 lx |
2700–3000 K |
The option to create lighting scenes is desirable. |
|
Kitchen |
200–300 lx |
3000–4000 K |
The worktop usually needs additional directional lighting. |
|
Office workplace |
Approx. 500 lx |
4000 K |
Assess UGR, CRI, uniformity and EN 12464-1. |
|
Sales floor |
300–500 lx |
3000–4000 K |
Additional accent lighting for goods is often required. |
|
Warehouse auxiliary area |
100–200 lx |
4000 K |
The type of work may require higher illuminance. |
Important: lux do not indicate the wattage of a specific panel. They describe the amount of light falling on a surface. The required number of luminaires is determined by assessing the actual light distribution of the luminaire and the room conditions.
Comparison of technical variants: W, lm, dimensions, colour
The category contains LED panels of different designs. The specific technical examples below help to compare the relationship between wattage, luminous flux, outer size and light colour.
|
LED panel variant |
Power |
Luminous flux |
Colour |
Outer dimensions |
Protection |
|
Slim round, universal mounting |
6 W |
450 lm |
2700 K |
Ø113 × 13 mm |
IP20 |
|
Slim round |
12 W |
1010 lm |
4000 K |
Ø160 × 13 mm |
IP20 |
|
Slim round |
18 W |
1570 lm |
4000 K |
Ø215 × 13 mm |
IP20 |
|
Round |
9 W |
45–55 lm/W |
2500–3000 K |
Ø148 × 20 mm |
IP20 |
|
Round |
18 W |
65–75 lm/W |
2500–3000 K |
Ø220 × 20 mm |
IP20 |
|
Square |
13 W |
1200 lm |
3000 / 4000 K |
140 × 140 × 47 mm |
IP20 |
|
Square |
17 W |
1600–1750 lm |
3000 / 4000 K |
165 × 165 × 47 mm |
IP20 |
|
Round, higher luminous flux |
24 W |
2400–2550 lm |
3000 / 4000 K |
Ø215 × 47 mm |
IP20 |
The table compares different catalogue designs. Where efficacy is given, the value in the “lm/W” column is not the luminous flux in lumens. The exact dimensions and power supply features of the chosen product are checked on the relevant product page.
Light colour – what do 2700 K, 3000 K, 4000 K and 6500 K mean?
|
Colour temperature |
Character of light |
Typical use |
|
2700 K |
Warm, more yellowish white |
Bedrooms, living rooms, relaxation areas |
|
3000 K |
Warm white |
Residential rooms, hotels |
|
4000 K |
Neutral white |
Offices, kitchens, common areas |
|
6500 K |
Cool, more bluish white |
Specialised work areas as needed |
Kelvin indicates the tint of the light, not its intensity. A 3000 K panel may emit more lumens than a 4000 K panel or vice versa. Colour tint is not the colour rendering index CRI / Ra.
Cut-out, outer size and recess depth
1. Outer diameter or width
The overall visible size of the panel housing, for example Ø190 mm or 165 × 165 mm.
2. Cut-out
The opening cut in the ceiling, whose size must match the specific fixing elements.
3. Installation height
The panel depth, for example 13, 20 or 47 mm – but this alone is not enough to determine the required cavity.
4. Driver location
A separate LED driver may need additional accessible space above the ceiling.
Before cutting the ceiling: check that there are no profiles, electrical cables, water pipes, ducts or other obstacles above the intended location. Measure the cut-out according to the documentation of the selected panel, not just the outer diameter stated in its name.
Spring clips and adjustable brackets
Some LED panels are fixed with spring clips that press the luminaire housing against the ceiling board. Some universal-mount models have adjustable brackets that allow the panel to be fitted into different cut-outs. However, the permissible ceiling thickness, bracket travel and fixing reliability must be checked.
Where are recessed LED panels used?
For home users
Neat ceiling lighting in the kitchen, living room, corridor, bedroom and study.
For lighting designers
The ability to choose luminous flux, distribution, colour temperature and the required illuminance.
For electricians
Recessed luminaires with different brackets, cut-outs and driver designs.
For architects and designers
Combining round and square shapes with the interior geometry and other lighting elements.
Recessed, surface-mounted or semi-recessed LED panel?
|
Type |
Main difference |
When to choose? |
|
Recessed / flush |
Most of the housing is hidden in the ceiling. |
When a suitable cut-out can be made and there is space above the ceiling. |
|
Surface-mounted |
Fixed onto the ceiling surface. |
When you do not want to or cannot cut an opening. |
|
Semi-recessed |
Part of the luminaire is recessed and part remains visible. |
When the construction or design requires a different degree of recessing. |
View surface-mounted LED panels at elsprendimai.eu →
Advantages and limitations of recessed LED panels
Pros
-
Minimalist ceiling appearance.
-
Wide choice of models and light colours.
-
Low energy consumption with adequate efficacy.
-
Possibility to plan an even layout of several luminaires.
-
Slim-profile designs for certain projects.
Cons and limitations
-
An accurately prepared ceiling cut-out is required.
-
A suitable installation cavity and heat dissipation are needed.
-
Not all models are dimmable.
-
Not all panels have a replaceable LED module.
-
If the wrong IP rating is chosen, use in damp areas may be unsafe.
Installation: from the ceiling cut-out to the electrical connection
1. Plan the lighting
Calculate the required luminous flux and the luminaire layout.
2. Check the ceiling construction
Assess the board thickness, cavity, profiles and possible obstacles.
3. Prepare the cut-out
Cut only an opening of the exact size permitted for the product.
4. Install the driver
Ensure a suitable location, access and cooling for the LED driver.
5. Connect the electrical circuit
Follow the wiring diagrams and the voltage and terminal requirements.
6. Secure the panel
Check the spring clips and that the panel sits flush.
7. Carry out a check
Assess electrical safety, operation, light uniformity and thermal conditions.
LED driver: different panels may have an integrated or a separate driver module. If the luminaire requires a constant-current LED driver, it must not be arbitrarily replaced with an ordinary 12 V or 24 V constant-voltage power supply. A replacement module must be electrically and thermally compatible.
Electrical safety: before installation work the electrical circuit must be disconnected and the absence of voltage verified. Luminaires must not be covered with thermal insulation materials unless their design permits such installation. Access to the connections and the driver must comply with the installation requirements.
Diagram: incorrect and correct LED panel installation
✗ WRONG
Selected LED panel
↓
Opening cut to the outer dimension
Driver and ceiling depth not taken into account
↓
Poor fixing or risk of overheating
The panel may not sit flush against the ceiling, the clips may not lock properly, and the driver may not have enough space.
✓ RIGHT
Technical dimensions of the luminaire
↓
Exact cut-out, suitable depth and electrical connection
Bracket compatibility checked
↓
Neatly installed LED panel
The panel sits flush against the ceiling, is properly secured and operates under the intended conditions.
How to calculate luminous flux and the number of luminaires?
Lighting design most often uses three quantities: W – electrical power, lm – luminous flux, lx – illuminance. They must not be confused.
W
Electrical power consumption.
lm
Total luminous flux of the light source.
lx
Illuminance on a given surface; 1 lx = 1 lm/m².
lm/W
Luminous efficacy of the luminaire.
Simplified formula:
N ≈ (E × S) / (Φ × UF × MF)
N – number of luminaires; E – desired average illuminance in lux; S – room area in m²; Φ – luminous flux of one luminaire in lm; UF – utilisation factor; MF – maintenance factor.
Calculation example: A 20 m² room is to achieve 300 lx. A 1200 lm LED panel is selected. With preliminary values UF = 0.6 and MF = 0.8, we get 300 × 20 / (1200 × 0.6 × 0.8) = 10.42, so initial planning would require approx. 11 such luminaires. This is an illustration – in a real project, their number and layout are refined by a photometric calculation. Fewer luminaires may suffice when using models with a higher luminous flux.
|
Panel power |
Example efficacy |
Luminous flux |
Note |
|
6 W |
75 lm/W |
450 lm |
Compact lighting |
|
12 W |
84.2 lm/W |
1010 lm |
Medium-size panel |
|
18 W |
87.2 lm/W |
1570 lm |
Higher luminous flux |
|
24 W |
100 lm/W |
2400 lm |
For general room lighting |
For professional projects: illuminance uniformity, glare (UGR), CRI, light flicker, photometric distribution, luminaire operating temperature and room reflectance factors are also checked. A “flicker-free” label without the corresponding parameters is not sufficient proof of quality.
Standards and key technical requirements
-
EN 60598-1 – general safety and test requirements for luminaires.
-
EN 60598-2-2 – particular requirements for recessed luminaires.
-
EN 12464-1 – requirements for indoor workplace lighting.
-
EN 62471 – photobiological safety assessment, where applicable.
-
IEC / EN 60529 – IP classification of enclosures.
-
EN 61000 series – electromagnetic compatibility requirements applicable to the relevant equipment.
-
LST HD 60364 – requirements for low-voltage installations.
The use, mounting position, driver replacement, dimming and suitability for damp areas of a specific luminaire are determined by its technical parameters and the electrical installation conditions.
FAQ – Kibirkštis asks, Fazė answers
12 practical questions about choosing recessed LED panels, luminous flux, ceiling cut-outs, electrical connection and lighting quality.
Kibirkštis How does a recessed LED panel differ from a surface-mounted one?
Fazė A recessed panel is installed in a specially prepared ceiling cut-out, so most of the luminaire body is concealed. A surface-mounted panel is fixed to the ceiling surface and does not require such an installation recess. Both options can be effective, but the choice depends on the ceiling construction, aesthetics and the preferred installation method.
Kibirkštis Does an 18 W LED panel always shine brighter than a 12 W one?
Fazė Not necessarily. Watts indicate the electrical power consumed, while luminous flux is measured in lumens. For example, a 12 W LED panel with an efficacy of 120 lm/W would emit 1440 lm, while an 18 W model with an efficacy of 70 lm/W – only 1260 lm. So compare not only the power, but also the luminous flux and light distribution.
Kibirkštis If the panel diameter is Ø190 mm, do I need to cut a Ø190 mm hole?
Fazė No. Ø190 mm often refers to the outer diameter of the luminaire, while the installation cut-out is usually smaller. The exact cut-out size depends on the specific model and the design of the spring clips. In an oversized cut-out, the panel may not lock in place. Always check the cut-out dimension before starting installation work.
Kibirkštis What is the difference between 3000 K and 4000 K LED panels?
Fazė 3000 K is warm white light, often chosen for living and relaxation spaces. 4000 K – neutral white, common in offices, kitchens and work areas. This is the colour temperature of the light, not an indicator of its brightness or electrical power. Both options can be equally bright if their lumen output is the same.
Kibirkštis Can I install an IP20 LED panel in a bathroom?
Fazė Only if the specific installation location permits a luminaire with this degree of protection. IP20 provides no protection against water. In a bathroom, the distance from the shower or bath, the electrical installation zones and the applicable safety requirements must be assessed. For water splashes or higher humidity, a luminaire with a suitable IP rating is selected.
Kibirkštis Can the brightness of all LED panels be dimmed?
Fazė No. For dimming, the LED panel and its driver must support a specific dimming technology. Some luminaires are non-dimmable, others may support phase-cut, 0–10 V, DALI or other control. Connecting a standard non-dimmable model to an incompatible dimmer may cause flicker, malfunction or equipment failure.
Kibirkštis Can a 230 V LED panel be connected directly to the mains?
Fazė The 230 V marking usually means the rated supply voltage of the whole luminaire, but this does not mean the LED module itself can be connected directly to the mains. Some luminaires have an integrated driver, others – a separate LED driver. Connect only to the designated 230 V input terminals and according to the wiring diagram. The LED module outputs must be kept separate from the mains connection.
Kibirkštis Is 13 mm of space enough if the LED panel height is 13 mm?
Fazė Not necessarily. 13 mm may be only the height of the panel housing. Additional space may be needed for the spring clips, electrical connections, the driver and heat dissipation. Even if the housing is very slim, check the installation dimensions of the complete set and the specifics of the ceiling construction.
Kibirkštis How many LED panels are needed for a 20 m² room?
Fazė First, determine the required illuminance, for example 150–300 lx, and know the luminous flux of the selected LED panel. Ceiling height, light distribution, wall colour and the purpose of the room also matter. A few luminaires with higher luminous flux can provide a similar total amount of light as a larger number of smaller ones, but the uniformity of their layout will differ. The exact quantity is determined by a photometric calculation.
Kibirkštis Do LED panels flicker or strain the eyes?
Fazė Not all panels have the same light flicker characteristics. Light quality depends on the driver, the LED control circuit and dimming. Flicker that is not visible does not necessarily mean that light modulation is low. For workplaces, it is also important to check UGR, adequate illuminance, CRI and the lighting layout.
Kibirkštis Which fails more often – the LEDs or the driver?
Fazė It depends on the specific design and operating conditions. Both the driver and the LED module can fail. Overheating, voltage fluctuations and insufficient ventilation can shorten the service life. If the driver is replaced, its output current, voltage range, power and control features must match the luminaire requirements.
Kibirkštis What information should I provide to get suitable LED panels selected?
Fazė State the purpose of the room, its area, ceiling height, desired light colour, existing or planned installation cut-outs and the preferred number of luminaires. If dimming, IP rating, low installation depth or glare control is important, state this as well. With these parameters, the panel design can be selected more precisely and lighting calculations can be carried out.
Kibirkštis and Fazė remind you
The right LED panel is selected by luminous flux, colour temperature and mounting design. Before installation, check the actual ceiling cut-out dimension, IP rating, driver and electrical safety requirements.
Recessed LED panels for homes, offices and commercial premises
Choose round and square recessed LED panels by luminous flux, colour temperature, size and installation cut-out. If you need help, send us the room parameters or the dimensions of the existing ceiling cut-out.
View recessed LED panels Contact us
The final lighting and electrical installation solution must comply with the luminaire's technical data and the applicable electrical safety requirements.
Recessed LED Panels – modern light sources designed for installation in ceiling structures (drywall, suspended ceilings, etc.). With their minimalist design, they look elegant, while LED technology ensures high light efficiency and low energy consumption. Suitable for both residential use (homes, apartments) and professional applications in offices, shops, industrial or public spaces.
Features
Energy saving – LED technology consumes up to 80% less electricity compared to traditional incandescent or fluorescent lamps.
Recessed installation – mounted flush with the ceiling, remaining flat without protruding.
Durability – service life typically ranges from 25,000 to 50,000 hours.
Wide light spectrum – available from warm (2700K) to cool (6500K) color temperatures.
Various sizes and shapes – square and round panels to suit different needs.
High luminous flux – ensures uniform lighting without shadows.
Applications
For home users: kitchen, living room, bathroom, or hallway – providing a clean, modern interior and comfortable lighting.
For engineers: in office, retail, school, or industrial lighting projects – delivering the required illumination level with low energy costs.
For electricians: convenient installation in drywall or suspended ceilings, easy connection to the electrical network.
For architects and designers: possibility to integrate a minimalist and aesthetic solution into modern interiors.
Pros
High energy efficiency.
Minimalist, aesthetic design.
Long lifespan and low maintenance.
Wide range of powers and shapes.
Uniform light distribution without flickering.
Cons
Requires recessed installation – a ceiling niche is necessary.
Not all panels are dimmable.
If the LED source fails, the entire panel often needs replacement, not just the lamp.
Recessed LED panels are an excellent choice for those seeking to combine modern design, energy savings, and long-term reliability. Suitable for both homes and professional projects in offices or commercial spaces. While their installation requires ceiling niches and may sometimes limit flexibility, these panels remain one of the most popular and reliable lighting solutions in today’s electrotechnical market.