Products catalog

Contactors | Electrical starters | For equipment control

  • Contactors are electromechanical switching devices operating on an electromagnetic principle, designed for automatic or remote switching of motors, pumps, fans, heating systems, lighting and other electrical loads.

    They are not intended for precise power regulation, motor speed control, overload protection or short-circuit protection – these functions require additional control and protective devices.

    KibirkštisFazė
    Which contactor does your motor need? A 30-second table from 2.2 to 45 kW with contactor and thermal overload relay is in the contactor and relay guide.
    Read more
  • ● Contactor – explained simply

    A contactor is an electrically controlled switching device that allows a low-power control circuit to switch a considerably higher-power electrical load on or off.

    Contactors are commonly used to control electric motors, pumps, fans, compressors, heating equipment, lighting groups and automation systems.

    ● How does a contactor work?

    A control voltage is applied to the contactor coil terminals A1–A2. The coil creates a magnetic field which mechanically operates the main and auxiliary contacts.

    This allows a push button, relay, PLC or another automation device to control an electrical load of considerably higher power.

    ● Contactor schematic designations

    These designations are used in electrical schematics and help identify the function of contactor terminals regardless of the language used in the documentation.

    KM contactor designation in an electrical schematic
    A1 – A2 electromagnetic coil terminals
    1L1 – 2T1 first main power contact
    3L2 – 4T2 second main power contact
    5L3 – 6T3 third main power contact
    13 – 14 NO – normally open auxiliary contact
    21 – 22 NC – normally closed auxiliary contact

    ● What do NO and NC mean?

    NO (Normally Open) – in the normal de-energised state, the contact is open. When the contactor operates, it closes.

    NC (Normally Closed) – in the normal de-energised state, the contact is closed. When the contactor operates, it opens.

    ● How to choose a contactor?

    A contactor should not be selected only by the highest current value shown on its housing.

    • Load type – motor, heater, lighting or another load.
    • Motor power – check the manufacturer's specified kW rating at the relevant supply voltage.
    • AC-3 current – one of the most important parameters when controlling asynchronous electric motors.
    • AC-1 current – mainly applies to resistive or slightly inductive loads.
    • Coil voltage – must correspond to the control circuit voltage.
    • Auxiliary contacts – NO and NC contacts are used for self-holding, interlocking, signalling and automation.
    • Number of poles – 3-pole contactors are commonly used for three-phase motors.

    ● Warning – coil voltage is not the main power circuit voltage

    If the contactor coil is marked 24 V AC, 42 V AC, 110 V AC or 230 V AC, this value refers to the A1–A2 control coil voltage. It must not be confused with the main power circuit voltage. Applying an incorrect voltage to the coil may damage the contactor.

    ● What do AC-1 and AC-3 mean?

    AC-1 – utilisation category for resistive or slightly inductive loads, for example electrical heating.

    AC-3 – one of the most important utilisation categories when controlling three-phase asynchronous motors. Therefore, a motor contactor should not be selected solely by its higher AC-1 rating – always check the AC-3 current and motor power.

    ● Where are contactors used?

    Electric motors Pumps Fans Compressors Heating equipment Lighting Conveyors Automation panels Refrigeration equipment Lifting equipment

    A contactor is generally used when an electrical load must be switched frequently, automatically or remotely.

    ● Key difference: contactor or relay?

    Contactor – mainly for power circuits.
    Relay – mainly for control and signalling circuits.

    A contactor is generally designed for larger loads and frequent switching. Relays are more commonly used in signalling, control and automation circuits and for smaller loads. This is a useful rule of thumb – the actual capabilities of a device must always be checked against the manufacturer's technical data.

    ● Common selection mistake

    A higher rated contactor current does not automatically mean that it is suitable for a particular motor. Motor starting current can be considerably higher than normal operating current, therefore the AC-3 category, motor power, supply voltage and manufacturer's recommendations must be considered.

    ● Quick terminology guide

    Coil electromagnetic part of the contactor supplied with the control voltage
    Main contacts contacts through which the main load current flows
    Auxiliary contacts contacts used for control, signalling, self-holding and interlocking
    AC-3 utilisation category particularly important for switching asynchronous electric motors
    NO normally open contact
    NC normally closed contact

    ● LOTO – Lockout / Tagout

    LOTO is a safety procedure for isolating, locking and identifying energy sources in order to prevent accidental or unauthorised energisation of equipment while work is being carried out.

    Where applicable, the energy source must be physically isolated, locked and clearly tagged. Re-energisation must only take place in accordance with the established safety procedure and by authorised personnel.

    ● DANGER – INCORRECT ELECTRICAL WORK CAN CAUSE SERIOUS INJURY OR DEATH

    Selection, connection, installation, replacement, adjustment and commissioning of electrical equipment must only be carried out by a specialist who has the qualifications, competence and authorisation required for the specific work.

    Contact with live parts, working on an improperly isolated circuit or incorrect connection of equipment is dangerous. Such errors may cause fatal electric shock, arc flash, severe burns, fire, explosion or equipment damage.

    Before starting work:

    • isolate all relevant energy sources;
    • protect the equipment against accidental re-energisation;
    • where applicable, use the LOTO lockout/tagout procedure;
    • verify absence of voltage using suitable test equipment;
    • use personal protective equipment appropriate for the work;
    • follow the manufacturer's documentation and applicable electrical safety and occupational safety requirements.

    If there is any doubt whether the work can be carried out safely, do not start the work and consult a qualified electrical professional.

    Read more
    Motor starting contactor with thermal overload relay, box and control push buttons | 0.25–15 kW | 0.63–32 A | ~380/400 V | control ~230 V | AC-3 | IP56 | direct-on-line / reversing | Promfactor Baltic | SKM
    Code: Variklio paleidimo kontaktoriai

    Promfactor SKM – motor starters with contactor, thermal overload relay 0.63–32 A and push buttons in an IP56 box, 0.25–15 kW; direct-on-line and reversing versions.

    Price 51.62 € - 118.73 € VAT incl.
    ( 42.66 - 98.12 € VAT excl. )
    Reversing motor starter contactor with thermal relay and enclosure with control buttons | 0.25kW | 0.63-1A | IP56 | Promfactor Baltic SKM0025R
    Code: SKM0025R

    High-quality reversing motor starter contactor designed for controlling three-phase asynchronous motors. The integrated thermal relay ensures effective overload protection, while the IP56-rated enclosure safeguards the device from dust, moisture, and mechanical damage. This model comes with convenient control buttons, allowing easy switching of the motor rotation direction. With its robust construction and high-quality components, this device guarantees long-term operation even in demanding working conditions.

    Price 92.32 € VAT incl.
    ( 76.30 € VAT excl. )
    Reversing motor starter contactor with thermal relay and enclosure with control buttons | 0.37kW | 1-1,4A | IP56 | Promfactor Baltic SKM0037R
    Code: SKM0037R

    High-quality reversing motor starter contactor designed for controlling three-phase asynchronous motors. The integrated thermal relay ensures effective overload protection, while the IP56-rated enclosure safeguards the device from dust, moisture, and mechanical damage. This model comes with convenient control buttons, allowing easy switching of the motor rotation direction. With its robust construction and high-quality components, this device guarantees long-term operation even in demanding working conditions.

    Price 92.19 € VAT incl.
    ( 76.19 € VAT excl. )
    Reversing motor starter contactor with thermal relay and enclosure with control buttons | 0.55kW | 1,3-1,8A | IP56 | Promfactor Baltic SKM0055R
    Code: SKM0055R

    High-quality reversing motor starter contactor designed for controlling three-phase asynchronous motors. The integrated thermal relay ensures effective overload protection, while the IP56-rated enclosure safeguards the device from dust, moisture, and mechanical damage. This model comes with convenient control buttons, allowing easy switching of the motor rotation direction. With its robust construction and high-quality components, this device guarantees long-term operation even in demanding working conditions.

    Price 92.19 € VAT incl.
    ( 76.19 € VAT excl. )
    Reversing motor starter contactor with thermal relay and enclosure with control buttons | 0.75kW | 1,7-2,4A | IP56 | Promfactor Baltic SKM0075R
    Code: SKM0075R

    High-quality reversing motor starter contactor designed for controlling three-phase asynchronous motors. The integrated thermal relay ensures effective overload protection, while the IP56-rated enclosure safeguards the device from dust, moisture, and mechanical damage. This model comes with convenient control buttons, allowing easy switching of the motor rotation direction. With its robust construction and high-quality components, this device guarantees long-term operation even in demanding working conditions.

    Price 92.19 € VAT incl.
    ( 76.19 € VAT excl. )
    Reversing motor starter contactor with thermal relay and enclosure with control buttons | 1.1kW | 2,2-3,1A | IP56 | Promfactor Baltic SKM0110R
    Code: SKM0110R

    High-quality reversing motor starter contactor designed for controlling three-phase asynchronous motors. The integrated thermal relay ensures effective overload protection, while the IP56-rated enclosure safeguards the device from dust, moisture, and mechanical damage. This model comes with convenient control buttons, allowing easy switching of the motor rotation direction. With its robust construction and high-quality components, this device guarantees long-term operation even in demanding working conditions.

    Price 92.19 € VAT incl.
    ( 76.19 € VAT excl. )
    Reversing motor starter contactor with thermal relay and enclosure with control buttons | 2.2kW | 3,5-5A | IP56 | Promfactor Baltic SKM0220R
    Code: SKM0220R

    High-quality reversing motor starter contactor designed for controlling three-phase asynchronous motors. The integrated thermal relay ensures effective overload protection, while the IP56-rated enclosure safeguards the device from dust, moisture, and mechanical damage. This model comes with convenient control buttons, allowing easy switching of the motor rotation direction. With its robust construction and high-quality components, this device guarantees long-term operation even in demanding working conditions.

    Price 92.19 € VAT incl.
    ( 76.19 € VAT excl. )
    Reversing motor starter contactor with thermal relay and enclosure with control buttons | 3kW | 4,5-6,5A | IP56 | Promfactor Baltic SKM0300R
    Code: SKM0300R

    High-quality reversing motor starter contactor designed for controlling three-phase asynchronous motors. The integrated thermal relay ensures effective overload protection, while the IP56-rated enclosure safeguards the device from dust, moisture, and mechanical damage. This model comes with convenient control buttons, allowing easy switching of the motor rotation direction. With its robust construction and high-quality components, this device guarantees long-term operation even in demanding working conditions.

    Price 92.89 € VAT incl.
    ( 76.77 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information