  • Copper cables BVV-PLL (OMYp). The cables are intended for fixed electrical installations, laid under plaster or in channels designed for electrical installations, suitable for installation in wet and dry premises. The conductor is twisted from thin strands of annealed copper wire, making it very flexible and easy to connect conductors to socket contacts. The cables are not suitable for laying underground or in water.  

  • Selection guide · flat flexible copper installation cables

    BVV-PLL (OMYp): where does it fit, how many cores do you need and how to choose the cross-section?

    Flat BVV-PLL cables are used for fixed electrical installations under plaster and in electrical installation trunking. Flexible copper cores make installation easier, but not every BVV-PLL variant suits every circuit. This guide will help you choose the number of cores, cross-section, length and the right installation method, and avoid mistakes with the PE conductor, overloads and damp environments.

    300/500 V
    Rated voltage U₀/U
    2–3
    Cores in the range
    0.5–2.5
    mm² cross-sections
    PVC/PVC
    Insulation and sheath
    Eca
    CPR class of the listed products
    Kibirkštis Fazė Asked by Kibirkštis – a young electrician. Answered by Fazė – an experienced engineer.
    Key point:

    BVV-PLL is a flexible flat PVC cable, but it is intended for fixed installation. Choose it after assessing the installation location, load current, number of cores and the conductor connection method. Especially important: the 2-core variant has no separate protective PE core, and the 300/500 V rating does not by itself confirm the cable is suitable for any 400 V circuit. The cable is not intended for direct burial in the ground or laying in water.

    Information and selection Suitable / benefit ⚠ Check ⚡ Safety and mistakes

    What do you need? Quick BVV-PLL selection

    First determine whether the cable will be used for fixed installation, how many conductors are needed and what the rated and continuous load of the circuit is. Below are indicative selection scenarios; they do not replace a specific electrical design.

    Need Option to consider Important
    Low-current circuit with no PE requirement BVV-PLL 2×1.0 white Use only where PE is not required and all requirements are met.
    Two-conductor circuit, lower resistance BVV-PLL 2×1.5 white The cross-section is coordinated with the protection and load.
    Two-conductor circuit, 2.5 mm² BVV-PLL 2×2.5 black Not intended for a circuit that requires a separate PE.
    Three-conductor circuit, low current BVV-PLL 3×0.75 white Check the core colours and functions before connection.
    Earthed 230 V socket outlet 3 conductors, including PE 2-core BVV-PLL is not suitable; a 3-core cable of appropriate construction and the design cross-section must be chosen.
    Laying in the ground or in water Not BVV-PLL A cable intended for such conditions is required.
    Constantly moving power cord Special flexible connection cable The flexibility of BVV-PLL does not mean continuous dynamic movement is permitted.

    The full BVV-PLL range in one matrix

    The category offers 10 variants. The cables differ in the number of cores, cross-section and colour. Clickable links are given only where a matching direct elsprendimai.eu product page exists; other variants can be found in this category’s product list.

    Cable Colour Cores Link
    BVV-PLL 2×1.0 White 2 × 1.0 mm² Open product →
    BVV-PLL 2×1.0 Black 2 × 1.0 mm² In category →
    BVV-PLL 2×1.5 White 2 × 1.5 mm² Open product →
    BVV-PLL 2×1.5 Black 2 × 1.5 mm² In category →
    BVV-PLL 2×2.5 White 2 × 2.5 mm² In category →
    BVV-PLL 2×2.5 Black 2 × 2.5 mm² Open product →
    BVV-PLL 3×0.5 White 3 × 0.5 mm² In category →
    BVV-PLL 3×0.75 White 3 × 0.75 mm² Open product →
    BVV-PLL 3×1.0 White 3 × 1.0 mm² In category →
    BVV-PLL 3×1.5 White 3 × 1.5 mm² In category →
    How to use the matrix? Choose the variant by the number of cores and cross-section. The white or black colour of the outer sheath does not identify the function of a phase, neutral or protective conductor. The core colours and their purpose must be checked separately.

    Where BVV-PLL fits and where it doesn’t

    ✓ Fixed indoor installation
    For electrical circuits where the cable laying and cross-section comply with the design.
    ✓ Under plaster
    The flat construction is convenient for straight, pre-planned installation routes.
    ✓ In electrical installation trunking
    The cable can be laid in trunking intended for this purpose in accordance with installation rules.
    ✓ Dry indoor rooms
    For fixed installation in residential and commercial premises.
    ⚠ Damp rooms
    Suitability depends on the connections, equipment, protection and installation location.
    ⚠ Socket outlets
    Check the PE, cross-section, current-carrying capacity and terminals suitable for flexible cores.
    ✗ Ground and water
    Not intended for direct laying in soil or in water.
    ✗ Continuous dynamic movement
    Not a substitute for drag-chain cables or cables for moving machinery.

    300/500 V: what does a cable’s rated voltage mean?

    The marking U₀/U = 300/500 V indicates the rated voltage between a conductor and earth (U₀) and between conductors (U). This means this voltage rating can be suitable for a 230/400 V low-voltage system, but the specific circuit solution depends on the number of cores and other operating requirements.

    300 V – U₀

    Rated voltage between the phase conductor and earth.

    230 V phase–earth: voltage rating is sufficient
    500 V – U

    Rated voltage between conductors.

    400 V between phases: voltage rating is sufficient
    ⚡ Important: The BVV-PLL range includes 2- and 3-core cables. They do not replace the five-core cable required for a three-phase circuit with L1, L2, L3, N and PE. The voltage rating does not remove the requirements for the number of cores and protective conductors.

    2 or 3 cores? Why is the PE conductor so important?

    2-core cable

    Two insulated conductors. Suitable only for circuits that do not require a separate protective PE conductor and where such a construction is permitted.

    There is no separate PE core.
    3-core cable

    Can be used for the phase, neutral and protective conductor if it includes a suitable green-yellow PE core and the required cross-section has been selected.

    Check the core colours.
    Kibirkštis
    KibirkštisIf I have a 2×2.5 mm² BVV-PLL, can’t I use one core for the phase, the other for neutral, and connect the earth separately somehow?
    Fazė
    FazėAn earthed socket circuit must have a properly installed and continuous PE. The safest standard solution is to choose, from the start, a cable that matches the design and has the required number of cores. PE must not be replaced by the neutral conductor or randomly connected to a metal structure.
    ⚡ Don’t confuse: 3×1.5 means three cores with a 1.5 mm² cross-section, but without checking the specific product’s marking you cannot automatically assume that one of them is a green-yellow PE.

    Cross-section according to load current and power

    The cable cross-section is determined not only by the power of the connected equipment. You must assess the installation method, the number of loaded cores, cooling, ambient temperature, grouping with other cables, the characteristics of the protective device and the voltage drop.

    This table shows the relationship between power and current for a single-phase 230 V resistive load at cos φ = 1. It is not a cable current-carrying capacity table.

    Power Current at 230 V What to check?
    100 W 0.43 A Purpose of the circuit and protection
    500 W 2.17 A Cable construction and cross-section
    1000 W 4.35 A Continuous current-carrying capacity
    2000 W 8.70 A Cooling and connections
    3000 W 13.04 A Design cross-section and protection
    3680 W 16.00 A The entire supply circuit, sockets, protection
    Single-phase circuit formula:
    P = U × I × cos φ
    Example: 230 V × 10 A ≈ 2300 W at cos φ = 1. For motors, efficiency and starting current are also taken into account.

    Electrical resistance of flexible copper cores

    Indicative maximum DC resistances of class 5 plain copper conductors at +20 °C:

    Core Resistance Ω/km Meaning
    0.5 mm² 39.0 Small loads, higher losses on long runs
    0.75 mm² 26.0 Lower resistance than 0.5 mm²
    1.0 mm² 19.5 Further reduced resistive losses
    1.5 mm² 13.3 Lower resistance, if suitable for the load and terminals
    2.5 mm² 7.98 Lower voltage drop at the same distance and current
    ⚠ This is not a load table. The permissible current and the protective device must be determined from the specific cable data and installation conditions. The fact that a cable is 2.5 mm² alone does not mean a 16 A MCB can be selected automatically.

    Cable length and voltage drop

    The longer the line, the greater its resistance to current. The table shows a simplified calculation for a single-phase 230 V circuit at a current of 10 A and a copper core temperature of +20 °C.

    One-way length 0.75 mm² 1.0 mm² 1.5 mm² 2.5 mm²
    5 m 2.60 V 1.95 V 1.33 V 0.80 V
    10 m 5.20 V 3.90 V 2.66 V 1.60 V
    20 m 10.40 V 7.80 V 5.32 V 3.19 V
    30 m 15.60 V 11.70 V 7.98 V 4.79 V
    Simplified formula:
    ΔU ≈ 2 × L × I × R / 1000
    L – one-way length in metres, I – current in amperes, R – resistance of one core in Ω/km. The factor 2 accounts for the length of the phase and return conductors.
    ⚠ Calculation limits: a heated conductor has a higher electrical resistance. The power factor, connections, voltage drop in other parts of the circuit and the relevant disconnection condition must also be taken into account. A low voltage drop does not prove that the cable’s current-carrying capacity is sufficient.

    BVV-PLL construction and technical data

    1. Flexible copper core
    The conductor is made of fine annealed copper wires, so it bends easily during installation.
    2. PVC insulation
    Each core is insulated from the others and from external conductive parts.
    3. Flat arrangement
    The cores are arranged in the cable construction so that it has a flat shape.
    4. PVC sheath
    Protects the insulated cores under normal permitted indoor conditions of use.
    Parameter BVV-PLL / OMYp
    Construction Flat flexible copper cable
    Conductor material Annealed copper
    Number of cores 2 or 3 in the variants of this category
    Cross-sections 0.5; 0.75; 1.0; 1.5; 2.5 mm² depending on variant
    Rated voltage 300/500 V
    Core insulation PVC
    Outer sheath PVC, white or black depending on variant
    Maximum core operating temperature +70 °C
    Short-circuit temperature Up to +160 °C for specific products, short-term
    Test voltage 2 kV for the listed products
    Installation temperature From −5 °C to +40 °C for the listed products
    Operating temperature From −30 °C to +70 °C for the listed products; without moving at low temperature
    Minimum bending radius More than 5 × cable thickness for the listed products
    CPR reaction-to-fire class Eca on specific product pages
    Main installation Fixed indoor installation, under plaster or in suitable trunking
    Unsuitable use Directly in the ground, in water and in unspecified aggressive environments
    ⚠ Temperature and flexibility: the −30 °C operating limit must not be understood as permission to bend or install the cable at such a temperature. Installation, handling and continuous operating conditions differ. Likewise, the +160 °C short-circuit value is not a permissible continuous operating temperature.

    Is BVV-PLL suitable for damp rooms? And what about the IP rating?

    BVV-PLL can be used in suitable dry and damp indoor rooms, but the cable itself must be distinguished from the protection of the entire electrical installation. The cable’s PVC sheath does not by itself give a socket outlet, junction box or electrical device a specific IP rating.

    Environment Assessment Note
    Dry living room Suitable According to the permitted installation method and the design.
    Kitchen or utility room Possible Protect connections from moisture and heat.
    Bathroom Only after assessing the zones Follow special electrical safety and IP requirements.
    Electrical installation trunking indoors Suitable subject to conditions Assess heat dissipation and cable grouping.
    Open air and direct UV exposure Not a standard application Choose a construction intended for such conditions.
    Soil, immersion in water Not suitable A special-purpose cable is required.
    ⚡ Electrical safety: in a damp room the entire connection matters – the cable route, junction box, entry seals, socket outlets, protective earthing and the required residual current protection.

    BVV-PLL or another copper cable?

    Type Construction / purpose Link to elsprendimai.eu
    BVV-PLL Flat, flexible, PVC, fixed installation BVV-PLL group →
    BVV-P Flat PVC cables, including variants with solid cores BVV-P group →
    BVV-F / BVV-PL Various constructions of round, flexible or flat installation cables BVV-F / BVV-PL →
    H03VV-F / H05VV-F Flexible connection cables for household appliances, by load class H03VV-F / H05VV-F →
    NHXMH-J Halogen-free cable for fixed indoor installation NHXMH-J group →
    CYKY-L Fixed power distribution cables of a different construction Copper cable catalogue →
    Selection rule: if you replace one cable with another, the same cross-section is not enough. Compare the core construction, number of cores, rated voltage, permitted laying method, CPR class and connection terminals.

    Installation: why do the flat shape and flexible cores matter?

    1. Route planning
    Lay the cable in permitted directions, taking into account the wall construction and future fixing points.
    2. Bending radius
    Do not kink the cable at a corner. Observe the bending radius specified for the specific product.
    3. Terminals
    Choose connectors that allow flexible stranded copper conductors to be connected.
    4. Mechanical protection
    Protect the cable from sharp edges, crushing and damage when drilling.
    5. Cable grouping
    Take into account temperature and reduced cooling in shared trunking.
    6. Check after installation
    Check the tightness of connections, PE continuity, insulation resistance and operation of the protection.
    Connecting a stranded core: not all socket or MCB terminals accept all conductor classes equally. If a terminal requires a ferrule, use a crimp ferrule of the appropriate cross-section and type and suitable crimping tools. Do not use unsuitable ferrules without checking, and do not tin conductor ends for screw connections.

    ⚠ What to check before buying?

    1. Purpose
    Do you really need a cable for fixed installation and not for a moving appliance?
    2. Number of cores
    Does the circuit need L, N and PE, or another combination of conductors?
    3. Cross-section
    Is the current-carrying capacity sufficient and the voltage drop within limits?
    4. Terminals
    Does the connecting device accept flexible stranded cores?
    5. Environment and laying
    Is use under plaster, in trunking or in a damp room permitted?
    6. CPR and quantity
    Does Eca meet the design requirements? Is the ordered length sufficient?

    Most common mistakes and their consequences

    ✗ Mistake ✓ Correct solution
    2×2.5 mm² is used for an earthed socket. Choose a suitable cable with PE and the required cross-section.
    It is assumed that 3 cores always mean L, N and PE. Check the core colours, functions and marking.
    0.5 mm² is chosen just because the appliance is low-power. Assess the minimum permitted cross-section for the specific installation and the protection.
    Flexible cores are forced into terminals not suitable for them. Use compatible connectors and ferrules where required.
    A PVC cable is considered halogen-free. Where low smoke is required, choose an LSOH cable of the required CPR class.
    BVV-PLL is laid in the ground or under water. Choose a cable intended for direct laying in such environments.
    Voltage drop on long routes is not assessed. Calculate the voltage losses of the entire circuit.

    ⚡ Fazė’s tip: safe connection of a flexible cable

    Fazė
    Fazė recommends

    The flat shape helps when installing the cable, but safety is determined not by the external shape but by correct design of the entire circuit. First choose the right PE conductor arrangement, then check the protective device, cross-section, connection terminals and laying method. A flexible stranded core must be connected so that the contact remains reliable throughout its service life.

    ⚡ Important: before electrical work, the power must be disconnected and the absence of voltage verified. Electrical installations must be designed, installed and tested by qualified specialists in accordance with applicable requirements.

    ☝ Elsprendimai.eu recommends

    When you need two cores

    Consider 2×1.0 or 2×1.5 mm² where PE is not required and the circuit permits it.

    When you need three cores

    See 3×0.75 and other 3-core variants. Check whether the PE and cross-section are suitable.

    When a lower voltage drop matters

    Compare 2×2.5 with smaller cross-sections, if a two-core construction is permitted.

    When a halogen-free construction is required

    See the NHXMH-J group and choose according to CPR and the design.

    Diagram: wrong / right – earthed socket circuit

    ✗ WRONG
    230 V supply
    ↓
    BVV-PLL 2×2.5
    L and N, no PE
    ↓
    Earthed socket outlet

    A two-core cable has no separate PE core. A large cross-section alone does not compensate for the missing protective conductor.

    ✓ RIGHT
    230 V supply with PE
    ↓
    3-core cable matching the design
    L, N and PE, suitable cross-section
    ↓
    Earthed socket outlet

    A cable construction with a suitable PE is chosen; current, protection, terminals and installation method are checked.

    The diagram is illustrative. Using a three-core cable for a specific circuit is permitted only after assessing the core colours, cross-section and design requirements.

    FAQ – Kibirkštis asks, Fazė answers

    Practical questions about BVV-PLL (OMYp) cables: number of cores, earthing, flat construction, cross-sections, permissible loads and installation limits.

    Kibirkštis
    Kibirkštis · Question 1What is BVV-PLL and how does it differ from an ordinary installation cable?
    Fazė
    FazėBVV-PLL, also marked OMYp, is a flat copper PVC cable with flexible cores. Its main purpose is fixed indoor installation, for example under plaster or in suitable trunking. It differs from solid-core cables in the flexibility of its conductors, which makes it easier to shape and connect. However, this does not mean it is intended for constantly moving mechanisms.
    Kibirkštis
    Kibirkštis · Question 2Is BVV-PLL 2×2.5 mm² suitable for an earthed socket outlet?
    Fazė
    FazėNot as a self-contained L, N and PE circuit. Two cores can perform only two conductor functions, while an earthed socket also requires PE. A larger cross-section alone does not replace the protective conductor. For such an installation, a cable matching the design with the required number of cores and a suitable PE is selected. See the section on 2 and 3 cores.
    Kibirkštis
    Kibirkštis · Question 3If a cable has three cores, is one of them always the earth?
    Fazė
    FazėNo. The marking 3×1.5 indicates the number of cores and the cross-section, but on its own it is not enough to confirm the presence of PE. Check the cable’s colour coding. The green-yellow core is intended for the protective function. If an L, N and PE connection is required, a suitable combination of all three cores must be chosen.
    Kibirkštis
    Kibirkštis · Question 4Can I use 0.5 or 0.75 mm² BVV-PLL for an ordinary 230 V socket installation?
    Fazė
    FazėNot just because the cable is rated 300/500 V. You need to check the minimum conductor cross-section permitted for the specific installation, the current-carrying capacity, the protective device parameters and PE. The 0.5 and 0.75 mm² variants are usually considered for smaller loads or special permitted circuits, not automatically for standard socket supply.
    Kibirkštis
    Kibirkštis · Question 5Can BVV-PLL 2×2.5 mm² always be protected with a 16 A MCB?
    Fazė
    FazėNot automatically. The cable’s current-carrying capacity depends on whether it is laid under plaster, in thermal insulation, in conduit or trunking, and whether other loaded cables are nearby. The MCB must be coordinated with the cable’s actual current-carrying capacity and disconnection conditions. It is also important that two cores are not an L, N and PE solution. More in the load selection section.
    Kibirkštis
    Kibirkštis · Question 6Can BVV-PLL be laid directly under plaster?
    Fazė
    FazėYes, this is one of its intended uses. However, you must observe installation zones, proper fixing, mechanical protection and the minimum bending radius. The flat shape can be useful on straight runs, but the cable must not be forcibly kinked at sharp corners.
    Kibirkštis
    Kibirkštis · Question 7If BVV-PLL is suitable for a damp room, does it have IP65 protection?
    Fazė
    FazėNo. The IP rating must be assessed for the relevant equipment or enclosure as a whole. The cable’s PVC sheath is not automatic proof that its connection meets IP65. A damp room requires suitable boxes, entries, sockets, PE and protective devices. In bathrooms, zone and installation requirements also apply.
    Kibirkštis
    Kibirkštis · Question 8The cable is very soft. Can I use it for a constantly moving machine?
    Fazė
    FazėFlexibility during installation and resistance to continuous dynamic flexing are different properties. BVV-PLL is intended for fixed installation. If the cable will flex in every work cycle, be pulled or operate in a drag chain, choose a cable specifically designed for such movement.
    Kibirkštis
    Kibirkštis · Question 9Can BVV-PLL be laid underground or outdoors?
    Fazė
    FazėBVV-PLL is not intended for direct burial in the ground or laying in water. It also cannot automatically be considered suitable for permanent outdoor use, as UV, water, frost and mechanical stress matter. For such an installation, choose a cable whose documentation clearly permits the intended environmental conditions.
    Kibirkštis
    Kibirkštis · Question 10How does BVV-PLL differ from BVV-P and BVV-LL?
    Fazė
    FazėBVV-PLL is a flat flexible cable intended for fixed installation. The BVV-P group contains flat solid-core cables, while the BVV-LL group is intended for a different type of flexible connections. When comparing, what matters is not only the cable shape but also the conductor class, rated voltage and purpose.
    Kibirkštis
    Kibirkštis · Question 11Is an Eca-class PVC cable halogen-free?
    Fazė
    FazėNo. Eca indicates the reaction-to-fire class, but it does not confirm low smoke or a halogen-free construction. BVV-PLL products use PVC. If the design requires a halogen-free cable and a specific CPR class, see the NHXMH-J group and check the DoP of the selected product.
    Kibirkštis
    Kibirkštis · Question 12I need 50 metres of cable. Is choosing 1.5 mm² enough if the load is small?
    Fazė
    FazėFirst determine whether this is a 50 m length of a single circuit or the total of several sections. For one long line, you need to calculate the voltage drop and check protection tripping and the permissible current. For example, for a current of 10 A over 30 m, a simplified +20 °C calculation for a 1.5 mm² flexible copper conductor gives a drop of about 7.98 V. More in the voltage drop table.
    Kibirkštis Fazė Question still unanswered? State the purpose of the installation, cable length, number of cores and load. Contact Elsprendimai.eu.

    Technical standards and important notes

    The following technical documents and requirements are important when selecting and installing BVV-PLL cables:

    Important technical information

    The external dimensions, core colours, permitted installation conditions and electrical characteristics of different BVV-PLL variants may differ. The conductor class, CPR class and temperature limits must be checked in the specific product’s technical documentation. The selection and voltage drop examples do not replace an installation design.

    Disclaimer: the tables and selection examples are provided for information purposes. The final cable cross-section, number of cores, protective devices and installation method must be determined by a qualified specialist according to the design and applicable requirements. UAB “Elektrotechnikos sprendimai” is not liable for the consequences of incorrect selection, erroneous calculations or non-compliant installation to the extent permitted by applicable law.

    Need BVV-PLL cable for a project?

    State the required number of cores, cross-section, colour, length and installation conditions. We will help assess the right variant, alternatives and supply of larger quantities.

    Contact Elsprendimai.eu

    Copper cables BVV-PLL are specially designed to meet high requirements for electrical energy transmission and distribution. These cables are characterized by reliability, flexibility, and durability, making them an ideal choice for various industrial and household applications.

    Construction:

    Conductors: Tinned, made from high-quality, ductile, and flexible copper wire, ensuring excellent electrical conductivity.
    Insulation: PVC (polyvinyl chloride) or XLPE (cross-linked polyethylene), providing reliable insulation and protection against mechanical damage, moisture, and chemicals.
    Construction Type: Cables are usually composed of several conductors that can be insulated or interconnected, depending on specific requirements.
    Specifications:

    Voltage: 300/500 V
    Temperature Range: From -15 °C to +70 °C (depending on the insulating material).
    Color Code: Typically uses brown (phase), blue (neutral), green-yellow (earthing), but may vary according to customer needs.
    Protection Class: The IP class may vary, but these cables generally provide good protection against dust and moisture.
    Applications:

    Industry: Ideal for industrial machines and equipment where high conductivity efficiency is required.
    Household Use: Used in lighting systems and household appliances, including refrigerators, freezers, and other electrical devices.
    Construction: Suitable for electrical installations in new and renovated buildings, both indoors and outdoors.
    Advantages:

    High Electrical Conductivity: High-quality copper conductors ensure efficient electrical energy transmission.
    Flexibility: The cables are easily manageable, allowing for easy installation and adaptation in complex locations.
    Resistance: Due to quality insulation, they are resistant to moisture, chemicals, and other adverse conditions, ensuring a longer service life.
    Copper cables BVV-PLL are an excellent choice for both industrial and household electrical solutions. Their reliability, efficiency, and durability ensure that they meet the highest standards necessary for reliable electrical energy transmission and distribution. These cables comply with European standards and are widely used in various fields, making them a great choice for both professionals and home users. 

    Read more
    No items found.
  • Subscribtion to new arrivals

    privacy policy

    Information