Analog Signal Converter | 1 Channel | 18-30VDC | 450Hz | DIN Rail | Phoenix Contact | MCR-C-UI/UI-450-DCI | 2810887
Code: MCR-C-UI-UI-450-DCIMCR-C-UI-UI-450-DCI is a single-channel analog signal converter and three-way galvanic isolator designed to electrically isolate, convert, and transmit standard voltage and current signals to control, measurement, or automation systems.
The input circuit, output circuit, and power supply circuit are electrically isolated from each other. Integrated DC/DC converters provide 3-way galvanic isolation, helping to protect the control system against potential differences, ground loops, and the adverse effects of interconnected sensor circuits.
This 450 Hz bandwidth version features a response time of up to 0.8 ms, making it suitable for transmitting faster-changing analog signals.
-
MCR-C-UI-UI-450-DCI analogue signal converter and 3-way isolator – configurable U/I input and output, 18–30 V DC, 450 Hz, DIN rail, 2810887
MCR-C-UI-UI-450-DCI – a single-channel analogue signal converter and three-way galvanic isolator designed to electrically isolate, convert and transmit standard voltage and current signals to a control, measurement or automation system.
The input circuit, output circuit and power supply circuit are electrically isolated from one another. Integrated DC/DC converters provide 3-way isolation, helping to protect the control system against potential differences, ground loops and the adverse effects of interconnected sensor circuits.
This 450 Hz cut-off frequency version offers a response time of up to 0.8 ms and is suitable for transmitting faster-changing analogue signals.
Primary application:
The module is used to isolate, convert and transmit analogue voltage or current signals between a sensor, measurement circuit, PLC, controller, data logger or another automation system. It can be installed close to the sensor, inside a control cabinet or along an analogue signal transmission line.Order code
2810887Isolation
3-wayCut-off frequency
450 HzPower supply
18-30 V DCNumber of channels
1Mounting
DIN rail3-way galvanic signal isolation
The module input, output and power supply circuit are galvanically isolated from one another. This design helps safely separate the sensor circuit from the signal evaluation or control circuit.
Three-way isolation is particularly useful in systems where different ground potentials, interference currents or ground loops may occur. The module can also reduce the adverse interaction of several interconnected sensor circuits.
Three circuits are isolated:
the analogue signal input, analogue signal output and the 18–30 V DC auxiliary power supply circuit.Analogue signal conversion
Available input signals
- 0-60 mV;
- 0-100 mV;
- 0-200 mV;
- 0-300 mV;
- 0-500 mV;
- 0-1 V;
- 0-2 V;
- 0–2.5 V;
- 0-5 V;
- 0-10 V;
- 0-20 V;
- ±60 mV to ±20 V;
- 0-5 mA;
- 0-10 mA;
- 0-20 mA;
- ±5 mA to ±20 mA;
- 1-5 V;
- 4-20 mA.
Available output signals
- 0-10 V;
- ±10 V;
- 0-5 V;
- ±5 V;
- 1-5 V;
- 0-5 mA;
- 0-10 mA;
- 0-20 mA;
- 4-20 mA.
Signal combination limitations:
Not every input signal can be combined with every output. The specific input and output combination must be checked against the manufacturer’s signal combination table.450 Hz version for faster signals
The cut-off frequency of this version at the 3 dB level is 450 Hz. The specified 10–90% response time is approximately 0.8 ms.
- suitable for faster-changing analogue signals;
- faster response than the standard 30 Hz version;
- signals are transmitted using an inductive transmission principle;
- a filter installed after the transmission stage helps reduce interference;
- maximum transmission error – no more than 0.1% of full-scale value.
Configuration and adjustment
According to the manufacturer’s documentation, the ranges are set using DIP switches, while final zero-point and span correction is performed using the ZERO and SPAN potentiometers.
- ZERO adjustment – for signal zero-point correction within ±2%.
- SPAN adjustment – for full-scale measurement range correction within ±2%.
- DIP switches – for setting the input and output signal ranges.
- Green power LED indicator – indicates the auxiliary power supply status.
Operating diagram and connection
- Terminal 1 – voltage or current signal input IN U/I.
- Terminals 2 and 3 – input circuit GND 1.
- Terminal 7 – current output OUT I.
- Terminal 8 – voltage output OUT U.
- Terminal 9 – output circuit GND 2.
- Terminal 10 – +24 V DC power supply.
- Terminals 11 and 12 – power supply circuit GND 3.
Technical specifications
Manufacturer / series MCR-C Model MCR-C-UI-UI-450-DCI Order number 2810887 Product type Analogue signal converter and galvanic isolator Number of channels 1 Galvanic isolation 3-way: input / output / power supply Configuration Yes, configurable and preset according to the order Standard voltage input 010 V, unless otherwise specified when ordering Maximum input voltage 30 V Maximum input current 50 mA Voltage input resistance 1 MΩ Current input resistance 50 Ω Standard voltage output 010 V Maximum output voltage 15 V Maximum output current 30 mA Voltage output load ≥10 kΩ Current output load ≤500 Ω Cut-off frequency, 3 dB 450 Hz Response time, 10–90% 0.8 ms Maximum transmission error ≤0.1% of full-scale value Temperature coefficient 0.0075%/K ZERO adjustment ±2 % SPAN adjustment ±2 % Supply voltage 18–30 V DC Maximum current consumption Less than 30 mA at no load Maximum power dissipation 900 mW Protective circuit Transient overvoltage protection Test voltage, input / output 1.5 kV AC, 50 Hz, 60 s Test voltage, power supply / signal 1 kV AC, 50 Hz, 60 s Operating temperature −20 °C to +65 °C Degree of protection IP20 Mounting method DIN rail mounting Mounting position Any Connection method Removable screw terminals Conductor cross-section 0.2–2.5 mm², solid or flexible AWG range AWG 24–14 Wire stripping length 8 mm Terminal screw thread M3 Dimensions W × H × D 17.5 × 99 × 114.5 mm Housing material Unreinforced polyamide PA Housing colour Green, RAL 6021 Compliance CE EMC immunity EN 61000-6-2 EMC interference emission EN 61000-6-4 Key features
- 3-way galvanic isolation – separates the input, output and power supply circuits.
- Configurable U/I signals – for different analogue voltage and current ranges.
- 450 Hz cut-off frequency – for faster-changing signals.
- 0.8 ms response time – for fast analogue signal transmission.
- ZERO and SPAN adjustment – for zero-point and range calibration.
- Green power LED – indicates the auxiliary voltage status.
- Removable screw terminals – for more convenient wire connection.
- 17.5 mm housing – for compact installation in an automation cabinet.
- DIN rail mounting – for standard control and automation cabinets.
Where is it used?
- PLC and controller analogue inputs – to isolate and condition a sensor signal.
- Process automation – for pressure, temperature, level, flow and other process signals.
- Measurement systems – for isolating and converting analogue signals.
- Industrial control cabinets – to reduce the effects of ground loops and potential differences.
- Longer signal transmission lines – for signal transmission across higher circuit loads.
- Sensor circuits – to safely separate the sensor from the evaluation circuit.
- Test and laboratory equipment – for transforming analogue signals.
- Building and energy automation – for standard 0–10 V, 0–20 mA and 4–20 mA signals.
Installation and connection
Mechanical installation
- the module is mounted on a standard DIN rail;
- the mounting position may be selected freely;
- housing width – 17.5 mm;
- use inside an enclosed electrical or automation cabinet;
- ensure an allowable ambient temperature of −20 °C to +65 °C.
Electrical connection
- removable M3 screw terminals are used;
- permitted conductor cross-section: 0.2–2.5 mm²;
- wire stripping length – 8 mm;
- power supply – 18–30 V DC;
- check the selected signal range before switching on.
Important operating notes
- Not all combinations of input and output ranges are permitted.
- Do not exceed an input voltage of 30 V or an input current of 50 mA.
- The voltage output load must be at least 10 kΩ.
- The current output load must not exceed 500 Ω.
- The IP20 housing is intended for installation inside a protected electrical or automation cabinet.
- Connection and configuration work must be performed by a qualified specialist.
- The ZERO and SPAN settings must be checked before commissioning the system.
Analogue signal conversion, 3-way isolation and 450 Hz transmission bandwidth
The MCR-C-UI-UI-450-DCI is a compact single-channel analogue signal converter that isolates the sensor, output and auxiliary power supply circuits. Three-way galvanic isolation helps protect the automation system against potential differences, ground loops and the effects of interconnected signal circuits.
Configurable voltage and current ranges allow the module to be adapted to a variety of analogue signal conversion tasks. The 450 Hz cut-off frequency and 0.8 ms response time allow faster-changing signals to be transmitted than with the standard 30 Hz version.
The 17.5 mm wide housing is mounted on a DIN rail, powered by 18–30 V DC and connected using removable screw terminals. The product is intended for industrial control, measurement and process automation systems requiring accurate analogue signal conversion and electrical circuit isolation.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products