Products catalog

  • Asymmetric cycle time relay | 12–240 V AC/DC | 16 A | 1 CO | control input S | DIN 1 module | OURTOP ATMT4-M1

    Code: ATMT4-M1

    Modular time relay that cycles its output on and off with separately set on (T1) and pause (T2) times.

  • Asymmetric cycle time relay | 12–240 V AC/DC | 16 A | 1 CO | control input S | DIN 1 module | OURTOP ATMT4-M1

    Modular time relay that cycles its output on and off with separately set on (T1) and pause (T2) times. Times are set with dials, supply 12–240 V AC/DC, output – 16 A changeover contact.

    Key point:
    When equipment must run in cycles – on for so long, off for so long – an asymmetric relay does it without a PLC or programming. On and pause times are set separately with knobs, and the wide supply suits almost any panel.
    Function
    cycle T1 / T2
    Supply voltage
    12–240 V AC/DC
    Contact rating
    16 A, 1 CO
    Mounting
    DIN 1 module

    Operating principle

    The relay mounts on a 35 mm DIN rail and takes one module; the 12–240 V AC/DC supply connects to A1–A2 and the load to the changeover contact 15-16-18.

    Knobs set the on time T1 and the pause time T2 separately. The relay repeats them while powered, and the control input S (A1-S-A2) lets an external signal start the cycle.

    The result: a fan, pump or signal runs at a precisely set rhythm without any programming.

    Why choose ATMT4-M1?
    Separate T1 and T2 allow, for example, 2 min on and 10 min off – something a simple symmetrical flasher relay cannot do.

    Technical specifications

    Product typeAsymmetric cycle time relay
    Manufacturer / modelOURTOP ATMT4-M1
    Supply voltage12–240 V AC/DC, 50/60 Hz
    Contact rating16 A / 250 V AC, 1 CO (15-16-18)
    External controlControl input S (A1-S-A2)
    FunctionCycle T1 / T2, times set separately
    MountingDIN 35 mm, 1 module
    MarkingCE

    Key functions

    • Asymmetric cycle – separate on (T1) and pause (T2) times.
    • Control input S – start the cycle with an external signal.
    • Universal supply – 12–240 V AC/DC.
    • 16 A changeover contact – NO and NC outputs.
    • Knob setting – no programming or display menus.

    Where is it used?

    • Cyclic fan operation
    • Pumps and mixers
    • Flashing beacons and sirens
    • Lubrication and dosing cycles
    • Filter blow-down
    • Livestock and greenhouse ventilation

    Use by need

    For the automation engineer.
    A simple cycle without a PLC – less programming and faster commissioning.
    For the electrician.
    One model for 12–240 V AC/DC – fits both 24 V and 230 V control circuits.
    For the farm owner.
    Ventilation or pumps run in cycles and do not run needlessly.

    Practical example

    If a barn fan must run for 5 minutes and rest for 15, ATMT4-M1 with T1 and T2 set repeats this rhythm around the clock, and via input S the cycle can be enabled only when the main switch is on.

    Advantages

    • Separate T1 and T2 times
    • 12–240 V AC/DC supply
    • 16 A changeover contact
    • Control input S
    • One DIN module

    Limitations

    • Single function – asymmetric cycle (not a multifunction relay)
    • Times are set with knobs, without a digital display
    • No overload or short-circuit protection – a circuit breaker is required

    Safety and installation notes

    • Install only with the power disconnected; work in the panel must be done by a qualified electrician.
    • Protect the supply and load circuits with a circuit breaker selected for the cable and load.
    • Change T1 and T2 only with the load safely disconnected or as the manufacturer instructs.
    • Use an intermediate contactor for motors and high-inrush loads.

    Quick selection guide

    cycle T1 / T2
    12–240 V AC/DC
    16 A, 1 CO
    DIN 1 module
    Suitable when you need:
    • Cyclic operation with different on and pause times
    • A simple solution without a PLC
    • Starting the cycle from an external signal
    Check before use:
    • That the required T1 and T2 fall within the manufacturer ranges
    • Load current does not exceed 16 A
    • Control input S wiring according to the diagram
    Important: ATMT4-M1 controls the operating rhythm but is not a protective device and does not replace a circuit breaker or motor protection.

    FAQ

    How does an asymmetric relay differ from a symmetrical one?
    The on (T1) and pause (T2) times are set separately.
    What is the supply voltage?
    12–240 V AC/DC, 50/60 Hz.
    What load can be connected?
    Up to 16 A / 250 V AC via the 15-16-18 changeover contact.
    What is input S for?
    To start the cycle with an external signal (A1-S-A2).
    How are the times set?
    With knobs on the front panel, T1 and T2 separately.
    How much panel space does it take?
    One DIN module.

    Asymmetric cycle time relay | 12–240 V AC/DC | 16 A | 1 CO | control input S | DIN 1 module | OURTOP ATMT4-M1

    ATMT4-M1 is an asymmetric cycle DIN-rail timer relay with separately set T1 and T2, 12–240 V AC/DC supply, a 16 A changeover contact and control input S. Suitable for fans, pumps, signalling and automation cycles.

    Published: 2026-11-19 · Data verified against the manufacturer specification: 2026-11-19

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.