Products catalog

  • Audio power amplifier | 800W | 70V / 100V / 4-16Ω | 230V | 483x337x49mm

    Code: ES-PA-800

    The power amplifier is designed for professional 70V / 100V and 4-16 Ω public address systems. It features microphone, AUX, and emergency ALARM priority inputs, making it suitable for background music, voice announcements, and emergency broadcasting in shopping centers, schools, hotels, offices, and industrial facilities. The 1U rack-mount design, forced-air cooling, and protection against overheating, overload, and short circuits ensure reliable operation in professional audio systems. 

  • Integrated Audio Power Amplifier – 800W, 70V / 100V / 4-16 Ω, 1U Rack, Class-D

    Integrated power amplifier designed for professional sound reinforcement, background music and voice announcement systems where microphone, line and emergency announcement inputs, as well as a powerful 70V / 100V or 4-16 Ω speaker output, are required in one device. The 1U rack enclosure, Class-D amplification, forced cooling and protection against overheating, overload and short circuit allow the device to be used in commercial and public facilities.

    Main idea:
    This model is intended for centralized 70V / 100V line and 4-16 Ω low-impedance sound reinforcement systems where an 800W amplifier with microphone, AUX, emergency alarm priority and protection functions is required.
    Rated power
    800 W
    Outputs
    70V / 100V / 4-16 Ω
    Enclosure
    1U rack
    Power supply
    AC 220V / 50Hz

    Operating principle

    The amplifier receives audio signals from a microphone, line-level AUX sources or an emergency announcement input, amplifies them and sends them to the connected speaker lines. The device supports 70V / 100V constant-voltage outputs for larger speaker lines and a 4-16 Ω low-impedance output for compatible speakers.

    The emergency alarm microphone input has the highest priority, so when this channel is activated, it can mute other sources. This is especially important in facilities where voice announcements or evacuation information must be transmitted clearly and without interruption.

    What do 70V / 100V and 4-16 Ω outputs mean?
    70V and 100V outputs are intended for line sound reinforcement systems where more speakers are connected on one line over longer distances. The 4-16 Ω output is intended for low-impedance speakers. These outputs must not be mixed arbitrarily – before connection, the correct speaker type must be selected and the total load must be calculated.

    Technical parameters

    Product type Integrated power amplifier
    Rated power 800 W
    Output modes 70V, 100V, 4-16 Ω
    Amplification class Class-D power amplification circuit
    Microphone inputs 1 standard MIC input + 1 emergency alarm MIC input
    Line inputs 2 standard line inputs / 4 audio source inputs
    Audio output 1 line audio output for another amplifier or system
    Input sensitivity / impedance MIC: 25mV / 600 Ω, AUX: 350mV / 10 kΩ
    Output sensitivity / impedance 1000mV / 470 Ω, unbalanced RCA
    Frequency range 50 Hz-16 kHz (+1 dB, -3 dB)
    Signal-to-noise ratio MIC: 66 dB, AUX1: 80 dB
    THD 0.5 % at 1 kHz, 1/3 rated power
    Priority function ALARM channel mutes other channels
    Channel crosstalk suppression ≤50 dB
    Indicators 3 level indicators, protection, distortion, power
    Cooling Forced air cooling from front to rear, fan activates from 55 °C
    Protections Overheating, overload, short circuit, SOA, negative feedback protection
    Power supply AC 220V / 50Hz
    Maximum consumption 950 W
    Dimensions 483 x 337 x 49 mm
    Weight Approx. 5.7 kg

    Key features

    • 800 W rated power – for larger sound reinforcement systems and speaker lines.
    • 70V / 100V line outputs – for centralized public address systems.
    • 4-16 Ω output – for compatible low-impedance speakers.
    • Class-D amplification – for higher efficiency and lower energy losses.
    • ALARM priority input – for emergency or evacuation announcements.
    • Independent volume control – for microphone and line inputs.
    • Line output – for transmitting signal to another amplifier.
    • Protection against overheating, overload and short circuit – for safer operation.
    • Forced cooling – for more stable operation under load.
    • 1U rack enclosure – for professional installation in an equipment cabinet.

    Where is it used?

    • Shopping centres – for background music, advertising and informational announcements.
    • Schools and universities – for bells, announcements, classrooms, corridors and halls.
    • Hotels – for reception areas, corridors, conference rooms and common areas.
    • Manufacturing companies – for workshops, warehouses, administrative and technical zones.
    • Office buildings – for general sound reinforcement and announcement systems.
    • Sports and cultural facilities – for halls, foyers, waiting areas and public spaces.
    • Evacuation announcement systems – where a priority ALARM channel is required.

    Practical usage example

    For example, in a shopping centre, the amplifier is installed in an audio equipment cabinet. Ceiling or wall speakers placed in corridors, retail areas and common spaces are connected to the 100V line. A music player is connected to the AUX input, and a paging microphone is connected to the microphone input.

    In normal mode, the system broadcasts background music, and when needed, an employee can transmit a voice announcement. When the ALARM channel is activated, the emergency announcement has the highest priority and can mute other audio sources.

    Use according to need

    For an audio system installer: suitable for 70V / 100V line systems and 4-16 Ω speaker solutions when a powerful 1U amplifier is required.

    For a facility administrator: allows background music, microphone announcements and emergency announcement priority to be managed in one device.

    For a public space: suitable for premises where clear speech, background music and reliable long-term operation are needed.

    For a technical room: the 1U enclosure allows the amplifier to be neatly installed in a standard 19" equipment cabinet.

    Advantages

    • 800 W power – for larger speaker lines.
    • 70V / 100V and 4-16 Ω outputs – for more flexible application.
    • ALARM priority input – for important announcements.
    • Class-D technology – for more efficient amplification.
    • 1U rack enclosure – saves space in the cabinet.
    • Forced cooling – for more stable operation.
    • Multiple inputs – for microphone, AUX sources and emergency channel.
    • Protection functions – against overheating, overload and short circuit.

    Disadvantages / limitations

    • Speakers must be selected correctly according to 70V / 100V or 4-16 Ω mode.
    • Not an IP network amplifier unless a separate network module or source is used.
    • Requires a 19" cabinet or suitable installation location.
    • High power requires responsible load calculation.
    • The fan may generate noise, so it is better to install it in a technical cabinet, not in a quiet room.

    Installation and usage notes

    Before installation, it is necessary to choose the correct output mode and calculate the total speaker load. In 70V / 100V lines, the power of the connected speaker transformers is calculated, while in 4-16 Ω mode the permitted total impedance must be observed.

    • Disconnect the amplifier power before connecting speakers.
    • Do not mix a 100V line and 4-16 Ω speakers without a suitable solution.
    • Do not exceed the amplifier’s 800 W rated power.
    • Leave a power reserve, especially in 100V line systems.
    • Ensure air circulation from front to rear.
    • Do not cover air intake and exhaust openings.
    • Test the emergency ALARM input function responsibly.
    • Installation is recommended to be entrusted to an audio system specialist.

    Quick selection guide

    Choose an 800 W integrated power amplifier when you need a professional 1U device for a 70V / 100V line or 4-16 Ω sound reinforcement system with microphone, AUX and emergency priority functions.

    Power
    800 W
    Outputs
    70V / 100V / 4-16 Ω
    Enclosure
    1U rack
    Dimensions
    483 x 337 x 49 mm
    Suitable when you need:
    • an 800 W power amplifier for a public address system;
    • a 70V or 100V speaker line;
    • a 4-16 Ω speaker output;
    • microphone, AUX and emergency announcement inputs;
    • 1U rack-type installation;
    • protection against overheating, overload and short circuit.
    Check before ordering:
    • whether a 70V, 100V or 4-16 Ω speaker system is used;
    • the total power of the speakers to be connected;
    • whether 800 W power is sufficient with reserve;
    • whether an emergency announcement priority input is required;
    • whether there is space in the equipment cabinet for a 1U amplifier;
    • whether proper ventilation is ensured.
    Important reminder:
    This model can operate with 70V / 100V lines or a 4-16 Ω load, but the loads must be calculated correctly. Incorrect speaker connection may cause overload, protection activation or equipment failure.

    FAQ – frequently asked questions

    Is this amplifier suitable for 100V speakers?
    Yes. The device has a 100V constant-voltage output and can be used in 100V line sound reinforcement systems.
    Can 4-16 Ω speakers be connected?
    Yes, the device has a 4-16 Ω output mode, but the permitted load limits must be observed.
    What does the ALARM input do?
    The ALARM channel has the highest priority and can mute other channels so that an emergency announcement is transmitted without interruption.
    Does the amplifier have protections?
    Yes. Protection against overheating, overload, short circuit and other output stage protection functions are provided.
    Can another amplifier be connected in a chain?
    Yes. The device has a line audio output that allows the signal to be transmitted to the audio input of another power amplifier.

    800W amplifier for professional public address systems

    The integrated 800W audio power amplifier is designed for facilities that require a reliable 70V / 100V line or 4-16 Ω sound reinforcement solution with microphone, AUX and emergency announcement functions.

    Thanks to Class-D amplification, 1U rack enclosure, ALARM priority, line output, forced cooling, 50 Hz-16 kHz frequency range and protection against overheating, overload and short circuit, this amplifier is suitable for shopping centres, schools, hotels, offices, manufacturing companies and other professional sound reinforcement systems.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information