Products catalog

  • Automatic pressure relay | switch 5-20bar | differential 2-5bar | 8A (24VDC) | 20A (125VAC) | 10A (250VAC)

    Code: ESLF5520

    Automatic pressure switch 5…20 bar, differential 2–5 bar, SPDT 10 A / 250 V AC. For pumps, compressors and refrigeration systems.

  • Automatic pressure relay | switch 5-20bar | differential 2-5bar | 8A (24VDC) | 20A (125VAC) | 10A (250VAC)

    Automatic pressure switch with an adjustment range of 5…20 bar and a differential of 2–5 bar. It switches a pump, compressor or fan on and off according to system pressure: when the set upper limit is reached the contact changes over, and when the pressure drops by the differential it returns.

    Key idea:
    When you need simple, reliable automation without a controller – for a water booster set, an air compressor or refrigeration system protection – a mechanical pressure switch is the most affordable and clearest solution. The SPDT changeover contact allows both switching on and protective switching off.
    Adjustment range
    5…20 bar
    Differential
    2–5 bar
    Contact
    SPDT, 10 A @ 250 V AC
    Medium
    refrigerants, air, water, oil

    Operating principle

    The switch is connected to the system via the pressure port and to the electrical circuit through the cable gland to the SPDT terminals. One screw sets the upper limit, the other the differential (difference between cut-in and cut-out).

    Pressure acts on a bellows / diaphragm which, via a spring and microswitch, changes over the contact. When the set pressure is reached the contact changes over, and when the pressure falls by the differential it returns.

    The result is automatically maintained system pressure or a protective cut-off when the pressure leaves the permitted range.

    Why choose the LF55 pressure switch?
    The adjustable differential lets you match the pump or compressor cycling rate to the system volume, and the changeover contact lets you choose whether the switch turns the load on or off as pressure rises.

    Technical specifications

    Product typeAutomatic (mechanical) pressure switch with adjustable differential
    Manufacturer / seriesLEFOO / LF55
    Adjustment range5…20 bar
    Differential2–5 bar
    ContactSPDT (changeover)
    Switching current8 A @ 24 V DC; 20 A @ 125 V AC; 10 A @ 250 V AC
    Mediumfluorinated refrigerants, air, water, oil (non-aggressive)
    Medium temperature−10…+120 °C
    Pressure connectionM12×1.25 or 7/16-20 UNF (depending on version)
    Cable glandfor cable Ø6–14 mm
    Dimensions83.5 × 90 × 44 mm
    Mountingwith standard mounting bracket

    Main functions

    • Adjustable upper limit – pressure set to the specific system.
    • Adjustable differential – fewer pump / compressor starts.
    • SPDT contact – for switching on or protective switching off.
    • Microswitch design – clean, stable switching.
    • Multiple media – refrigerants, air, water, oil.
    • No power supply needed – the switch directly switches the load circuit.

    Where is it used?

    • Water booster sets and pumps
    • Air compressors
    • Refrigeration and air conditioning – high / low pressure protection
    • Heating boilers and pressurisation units
    • Hydraulic and oil systems
    • Irrigation systems
    • Pressure alarms in industrial equipment

    Use by need

    For plumbers / pump installers.
    Simple pump on/off control by pressure without a controller.
    For refrigeration technicians.
    Compressor protection against too high or too low pressure.
    For equipment manufacturers (OEM).
    One switch type for many pressure ranges and media.

    Practical application

    If a water booster set must maintain 3–4 bar, choose a switch whose range includes 4 bar (e.g. 1…10 bar), set the upper limit to 4 bar and the differential to 1 bar: the pump starts when pressure falls to 3 bar and stops at 4 bar.

    Pros

    • Simple mechanical automation without a controller
    • Adjustable limit and differential
    • SPDT changeover contact
    • Wide range choice: from −0.5 to 42 bar
    • Suitable for refrigerants, air, water and oil

    Cons / limitations

    • Does not output an exact pressure value – a pressure transmitter is needed for that
    • Larger motors (above the contact rating) need a contactor
    • Not for aggressive media
    • Manual setting, no display

    Safety and installation notes

    • Install and adjust only with the voltage disconnected and the system depressurised.
    • Do not exceed the contact current – use a contactor for larger loads.
    • Check that the pressure connection matches the system thread.
    • Tighten the cable gland to keep the housing sealed.
    • After setting the limits, verify operation with a pressure gauge.

    Quick selection guide

    Range 5…20 bar
    Differential 2–5 bar
    SPDT 10 A / 250 V AC
    Refrigerants / air / water / oil
    Suitable when you need:
    • to switch a pump or compressor by pressure
    • to protect the system against too high or too low pressure
    • a simple solution without electronics
    Check before use:
    • the working pressure is inside the switch range
    • the load current does not exceed the contact rating
    • the pressure connection fits
    Important reminder: a pressure switch does not replace a safety valve – it must be installed separately in the system.

    FAQ

    Does the switch need a separate power supply?
    No, it mechanically switches the load circuit.
    What does differential mean?
    It is the difference between the cut-out and cut-in pressure.
    Can a pump be connected directly?
    Yes, if the motor current is within the contact rating; otherwise via a contactor.
    Is it suitable for water?
    Yes, it is suitable for water, air, oil and refrigerants.
    How do I choose the range?
    The working pressure should be inside the range, not at its edge.
    Can it be used as protection?
    Yes, the SPDT contact can open the circuit when the set pressure is exceeded.

    Automatic pressure relay | switch 5-20bar | differential 2-5bar | 8A (24VDC) | 20A (125VAC) | 10A (250VAC)

    LEFOO LF55 automatic pressure switch 5…20 bar, differential 2–5 bar, SPDT contact – for control and protection of pumps, compressors and refrigeration systems.

    Published: 2026-11-16 · Data verified against the manufacturer's datasheet: 2026-11-16

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information