
Miniature circuit breaker | 2P | 6A | C | 6kA | DIN | MCB | Merlin Gerin | Multi9 C60N | 24267
Code: 24267Price 23.56 € VAT incl.( 19.47 € VAT excl. )The Merlin Gerin Multi9 C60N circuit breaker is a high-quality device designed to protect electrical circuits from short circuits and overloads. It belongs to the C series, which ensures a quick response to high current surges, allowing the user to quickly restore power when the system experiences a disruption. The breaker has a two-pole (2P) design, making it suitable for both single-phase and three-phase systems, and is intended for use in low or medium voltage applications.
The C60N model ensures the circuit breaker is reliable and resistant to everyday use in industrial, commercial, or residential settings, providing a high level of safety.
-
Miniature circuit breaker | 2P | 6A | C | 6kA | DIN | MCB | Merlin Gerin | Multi9 C60N | 24267
Merlin Gerin (Schneider Electric) Multi9 C60N series 2-pole miniature circuit breaker, 6 A, C curve. It protects the circuit against overload and short circuit and mounts on a 35 mm DIN rail. C60N is the industrial and commercial version of the Multi9 range.
Key point:
Multi9 C60N breakers are still installed in many panels. When one fails, the same code 24267 keeps the panel uniform and fits the existing busbars and accessories (Vigi C60, auxiliary contacts).Poles / current
2P / 6 ACurve
CBreaking capacity
6000 A (EN 60898)Voltage
230/400 V AC (≤ 440 V AC)Operating principle
The breaker clips onto a DIN rail; wires connect to screw terminals. In normal operation it simply carries the current.
The thermal release reacts to sustained overload, the magnetic release to short circuit. The C curve trips at 5–10 × In, suitable for general-purpose circuits.
After tripping the breaker stays in the OFF position and is reset manually once the fault is cleared.
Why choose 24267?
It is an exact match for the original Multi9 C60N breaker – no need to rebuild the panel or change busbars.Technical specifications
Product type Miniature circuit breaker (MCB) Manufacturer / series Merlin Gerin (Schneider Electric) / Multi9 C60N Manufacturer code 24267 Number of poles 2P Rated current In 6 A Tripping curve C curve (5–10 × In per EN 60898) Rated operational voltage Ue 230/400 V AC (≤ 440 V AC) Frequency 50/60 Hz Breaking capacity Icn (EN 60898) 6000 A Breaking capacity Icu (IEC 60947-2) 20 kA (230–240 V AC), 10 kA (400–415 V AC), 6 kA (440 V AC) Series current range 1–63 A Mounting 35 mm DIN rail, clip-on Width / height 36 mm / 81 mm Mechanical durability 20,000 cycles Standards EN 60898, IEC 60947-2 Product status Discontinued by the manufacturer; current Schneider equivalent – Acti9 iC60 series Main functions
- Overload protection – disconnects the circuit before cables overheat.
- Short-circuit protection – the C-curve magnetic release acts instantly.
- All-pole tripping – all 2 poles open together.
- Compatibility – fits Multi9 busbars and accessories.
- Position indication – the lever clearly shows ON/OFF.
Where is it used?
- Lighting and socket circuits
- Single-phase circuits with phase and neutral disconnection
- Existing distribution panels with Multi9 C60N equipment
- Commercial building and production panels
- Replacing a failed breaker with the same code
- Repair and maintenance work
Use by need
For facility managers.
Only the failed breaker is replaced; the panel and documentation stay the same.For electricians.
Same C60N housing – no need to cut busbars or replace neighbouring devices.For purchasing.
Order this discontinued code together with other electrical items, with a VAT invoice.Practical use
If 24267 fails in a panel with Multi9 equipment and identical breakers sit next to it, you replace it with the same code – busbar, labelling and panel diagram remain unchanged.Advantages
- Original Merlin Gerin code
- Breaking capacity 6000 A per EN 60898
- Fits Multi9 busbars and accessories
- Complies with EN 60898 and IEC 60947-2
- Pickup available in Šiauliai
Disadvantages / limitations
- Discontinued – for new panels choose Acti9 iC60
- No residual current protection – a separate RCD is required
- For DC applications check the parameters in the manufacturer catalogue
Safety and installation notes
- Installation only by a qualified electrician, with power off and absence of voltage verified.
- Poles, current and curve must match the breaker being replaced.
- The breaker current must not exceed the cable current rating.
- Short-circuit current at the installation point must not exceed 6000 A.
- Tighten terminals properly – a loose contact heats up.
Quick selection guide
2P6 AC curve6000 AMulti9 C60NSuitable when you need:- to replace a Multi9 C60N breaker with the same code;
- 2P, 6 A, C-curve protection.
Check before use:- the old breaker code and curve;
- supply voltage and short-circuit current;
- cable cross-section and terminal type.
Important reminder: a circuit breaker does not replace a residual current device (RCD) or surge protector – these are separate protective devices.FAQ
Is this an original Merlin Gerin breaker?
Yes, Merlin Gerin (Schneider Electric) Multi9 C60N, code 24267.What replaces it if I need a current model?
The current Schneider equivalent is the Acti9 iC60 series.Does it fit a DIN rail?
Yes, it mounts on a 35 mm DIN rail.What does 6000 A mean?
It is the breaking capacity per EN 60898 – the highest short-circuit current the breaker can safely interrupt.Does it protect against electric shock?
No, that requires a residual current device (RCD).Can I pick it up in Šiauliai?
Yes, J. Basanavičiaus g. 23, Šiauliai.Miniature circuit breaker | 2P | 6A | C | 6kA | DIN | MCB | Merlin Gerin | Multi9 C60N | 24267
Original Merlin Gerin Multi9 C60N miniature circuit breaker 24267: 2P, 6 A, C curve, 6000 A per EN 60898. For replacing a failed breaker in an existing panel.
Published: 2026-11-20 · Data verified against the manufacturer datasheet: 2026-11-20
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerCircuit breakers, also known as protective breakers or circuit interrupters, are essential components of electrical protection systems. They automatically disconnect the electrical circuit when it becomes overloaded or when a short circuit occurs. They are used in electrical installations to protect equipment and people from electrical faults. Circuit breakers come in various types and have different characteristics depending on the installation location, circuit load, and other specifications.
Circuit Breaker Characteristics:
B, C, and D Characteristics:
B characteristic: Used in residential areas or low-load systems. They operate when the current exceeds the nominal current by 3 to 5 times.
C characteristic: Commonly used in both residential and commercial or industrial spaces. Their operating threshold is 5 to 10 times the nominal current, making them suitable for loads with high inrush currents (e.g., motors, lighting systems).
D characteristic: Used in industrial installations where loads have very high inrush currents (e.g., compressors, transformers). They operate when the current exceeds the nominal by 10 to 20 times.
Advantages (Pros) of Circuit Breakers:Safety: Circuit breakers ensure that the circuit is automatically disconnected in case of overload or short circuit, preventing wire burning, equipment damage, or even fires.
Reliability: They are highly reliable and can operate for long periods without maintenance, reacting automatically when electrical faults occur.
Ease of use: There is no need to replace the breaker after it trips. After an overload or short circuit, the circuit breaker can simply be reset to its operational position, avoiding the need to replace fuses.
Precision: Circuit breakers operate accurately according to the nominal current and circuit characteristics, ensuring minimal unnecessary power interruption.
Protection against short circuits and overloads: Breakers not only protect against short circuits but also against prolonged overloads, which can be harmful to electrical systems.
Versatility: There are various types of circuit breakers suitable for different systems, from small household installations to large industrial systems.
Easy reset: After a trip, the breaker can simply be reset without the need to replace it (unlike fuses that need to be replaced after a trip).
Disadvantages (Cons) of Circuit Breakers:High cost: Circuit breakers, especially those with more complex functions (e.g., adjustable protection limits), are more expensive than simple fuses.
Limited operating range: While breakers provide protection against overloads and short circuits, they cannot protect against all types of electrical faults, such as overvoltage. Additional protection devices are required for that.
Larger size: Circuit breakers are generally larger than fuses, meaning their installation may require more space in the distribution panel.
Limited protection against frequent overloads: If the electrical system experiences frequent overloads, circuit breakers may not fully protect equipment from long-term damage caused by continuous overload exposure.
More complex repair: Some complex circuit breakers may require more maintenance or repairs if they malfunction or trip incorrectly.
Applications of Circuit Breakers:Household Installations:
B characteristic breakers are most commonly used in residential installations to protect circuits from short circuits and overloads. They are suitable for lighting circuits, plugs, and other low-load devices.
C characteristic breakers are also used in homes but are better suited for areas with higher inrush currents, such as electric motors or heaters.
Commercial and Industrial Installations:C characteristic breakers are often used in commercial and industrial buildings. They are suitable for electrical equipment with medium inrush currents.
D characteristic breakers are used in industrial equipment where large inrush currents occur, such as for heavy motors, transformers, or high-power equipment protection.
Large Mechanisms and Industrial Equipment:D characteristic breakers are used where the inrush currents are very high. This includes electrical network distribution sections, industrial machinery, and transformers.
Protection of Electronics Equipment:Certain types of circuit breakers are used to protect electronic equipment, such as in server rooms or other sensitive systems where fast and precise protection is required.
Conclusion:
Circuit breakers are essential in modern electrical systems to ensure safe power supply and protection from faults. They have many advantages, such as reliability, safety, and easy resetting, but they also have some drawbacks, such as higher cost and larger size. Their selection depends on the intended use and required protection parameters.K – Trips when the current is 8-12 times higher than the nominal current, designed to protect circuits powering motors, capacitors, and transformers.
S – Trips when the current is 13-17 times higher than the nominal current, designed for the protection of control transformers.
Z – Trips when the current is 2-3 times higher than the nominal current, designed for the protection of computer equipment and other electronic components and devices.
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products





