- -13.75€

Differential pressure switch | 50-500Pa | changeover contact | 250VAC | IP54 | with PVC tubes and nozzles | Sentera Controls | PSW--500-PVC
Code: PSW--500-PVCOffer is valid until 2026-12-31Price 24.55 € VAT incl.( 20.29 € VAT excl. )38.30 €You save 13.75 €Want another price? Suggest yours! -
Differential pressure switch | 50-500Pa | changeover contact | 250VAC | IP54 | with PVC tubes and nozzles | Sentera Controls | PSW--500-PVC
The PSW--500-PVC is a Sentera Controls adjustable differential pressure switch for the 50–500 Pa range. It monitors overpressure, vacuum or pressure difference in air and, when the set limit is reached, switches a dry changeover contact. The kit includes PSET-PVC connection nozzles, PVC tubes and mounting screws.
Key idea:
This is the simplest and most reliable way to obtain a “pressure present / no pressure” signal: a clogged filter, a stalled fan or insufficient flow is passed straight to the automation or an alarm – without power supply or programming.Control range
50–500 PaContact
Changeover, 1.5 (0.4) A / 250 VACSwitching differential
ΔP 20 PaProtection class
IP54 (with cover)Operating principle
The switch is mounted on a suitable surface. Nozzle P1 is connected to the higher-pressure (or lower-vacuum) point, P2 to the lower-pressure (or higher-vacuum) point. The wires are routed through the PG 11 gland to terminals 1 (NC), 2 (NO), 3 (COM).
A silicone diaphragm responds to the pressure difference between P1 and P2. The switching threshold is set with a graduated, calibrated knob under the cover. As the pressure difference increases and reaches the set threshold, contact 3–2 closes and 3–1 opens. The switching differential (hysteresis) is 20 Pa. The contact is voltage-free, so it can be connected to a controller input, a relay coil or a signalling circuit.
Result – the automation or signalling circuit receives a clear binary signal about a clogged filter, a stopped fan or an interrupted airflow. Engineer's note: when the switching threshold is below 50 Pa, the switch must not be mounted upside down – the weight of the diaphragm would affect the switching point. Accuracy per EN 1854 – ≤ ±15 % (min. ±10 Pa), so the switch is intended for monitoring and protection, not for precise measurement.
Benefits PSW--500-PVC?
A simple pressure monitor that is independent of the power supply, with a changeover contact and a mechanical life of 10 000 000 cycles – with everything needed for connection to the duct.Technical specifications
Product type Differential pressure switch (pressure switch) Manufacturer / code Sentera Controls / PSW--500-PVC Series PSW (20–200 Pa / 50–500 Pa; with or without the PVC kit) Control range 50–500 Pa (0.5–5.0 mbar) Switching differential ΔP 20 Pa (0.2 mbar) Contact Changeover: 1 – NC, 2 – NO, 3 – COM Switching capacity Max. 1.5 (0.4) A / 250 VAC (VDE 0630) Max. operating pressure 10 kPa Accuracy ≤ ±15 %, min. ±10 Pa (EN 1854) Mechanical life 10 000 000 cycles Diaphragm Silicone Medium Air and other non-flammable, non-aggressive gases Pressure connections + (P1) and − (P2) Cable entry PG 11 Protection class IP54 with cover, IP00 without cover (EN 60529) Operating temperature -20…+85 °C Storage temperature -40…+85 °C Humidity < 95 % rH non-condensing Scope of delivery Switch, PSET-PVC nozzles (r-ABS, 83 mm, connection end Ø6.4 mm), PVC tubes Ø7 mm (max. 10 000 Pa, up to 60 °C), mounting screws Compliance LVD 2014/35/EU, WEEE 2012/19/EU, RoHS (EU) 2015/863, Gas Appliances Regulation 2016/426/EU, EN 1854 Main functions
- Adjustable switching point – graduated knob within 50–500 Pa.
- Changeover contact – NO and NC – suitable for both alarm and interlock.
- No power supply needed – the relay is mechanical – it works independently of the automation power supply.
- Long service life – 10 000 000 switching operations.
- Silicone diaphragm – no outgassing, stable operation.
- Complete set – nozzles, tubes and screws – install straight away with no extra purchases.
Where is it used?
- Range 50–500 Pa – for monitoring higher-pressure filters and fans
- Air filter contamination monitoring
- Fan operation monitoring (flow presence)
- Overheat protection for duct electric heaters
- Heat exchanger frost protection in air handling units
- Control of air and fire dampers
On-demand operation
For commercial building ventilation contractors.
The complete kit with nozzles and tubes shortens the installation of higher-pressure (50–500 Pa) filter monitoring.For maintenance companies.
A graduated knob under the cover allows the switching threshold to be adjusted on site according to the filter manufacturer's final pressure drop.For damper control system installers.
The changeover contact and IP54 with a cover suit air and fire damper control circuits.Practical application
If filter contamination has to be monitored in a unit with a larger air volume, then the PSW--500-PVC with the supplied PSET-PVC nozzles and PVC tubes is connected before and after the filter, and when the limit is set with the knob within the 50–500 Pa range, contact 3–2 signals that the filter must be replaced.Application guide: how it is used in practice
The PSW--500-PVC adapts to different monitoring tasks – only the connection points and the use of the contact change:
Site What is connected Result Installer's note Filter fouling monitoring P1 before the filter, P2 after the filter When the filter becomes clogged, the contact switches and gives a “replace filter” signal Set the limit according to the filter manufacturer's final pressure drop Fan operation monitoring P1 on the fan pressure side, P2 in the atmosphere or on the suction side Alarm if the fan is not turning or the belt has broken Use contact 3–2 as "flow present" Electric duct heater Relay NO contact → heater enable circuit The heater is switched on only when there is airflow Install according to the heater manufacturer's instructions Heat exchanger in winter P1 / P2 before and after the heat exchanger A rising pressure drop indicates frosting – the automation starts defrosting Protect the tubes from condensate freezing How to choose the range of a pressure switch
Switching range / package contents Recommended model 20–200 Pa, relay only PSW--200 (20–200 Pa) 20–200 Pa, with PVC connection kit PSW--200-PVC (20–200 Pa, with tubes) 50–500 Pa, relay only PSW--500 (50–500 Pa) 50–500 Pa, with PVC connection kit PSW--500-PVC (50–500 Pa, with tubes) ← this model Rule: the desired switching point should be closer to the middle of the range: up to ~150 Pa – PSW--200, for higher limits – PSW--500. If nozzles and tubes are not available on site, choose the version with the PVC kit.When to choose another solution: version without a connection kit – PSW--500; for smooth pressure measurement with an analog output – HPS-2 / DPS-2 transmitters; for pressure maintenance by a fan – HPSP-2 / DPSP-2 controllers.Pros
- Mechanical, no power supply required
- Changeover NO / NC contact
- Adjustable switching point
- 10 000 000 cycle service life
- IP54 with cover
- Nozzles and tubes included
Cons / limitations
- Accuracy ≤ ±15 % – not suitable for precise measurement
- Binary signal only, no analog output
- With a limit < 50 Pa it must not be mounted upside down
- Only for air and non-flammable, non-aggressive gases
Safety and installation notes
- Installation and connection must be carried out by a qualified electrician with the power disconnected.
- Contact load – no more than 1.5 (0.4) A / 250 VAC.
- Do not operate without the cover – without it the protection class is IP00.
- Max. operating pressure – 10 kPa; for air and non-flammable, non-aggressive gases only.
- When the switching threshold is below 50 Pa, do not mount upside down.
- Max. operating temperature of the PVC tubes – 60 °C.
Quick selection guide
50–500 PaΔP 20 PaNO / NC250 VACIP54Suitable when you need:- to monitor filter fouling and fan operation;
- to interlock the electric heater when there is no airflow;
- to obtain a simple pressure signal without power supply and programming.
Check before use:- whether the desired switching threshold fits within 50–500 Pa;
- the contact load (up to 1.5 (0.4) A / 250 VAC);
- whether connection nozzles and tubes are needed.
Important reminder: The PSW--500-PVC provides only an on / off signal; for smooth pressure measurement or control, a pressure transmitter or controller is required.FAQ
How is the switching pressure set?
Graduated knob under the cover.Which contact closes as the pressure increases?
As the pressure difference increases, 3–2 closes and 3–1 opens.Where do I connect P1 and P2?
P1 – to the higher pressure (lower vacuum), P2 – to the lower pressure (higher vacuum).Is a power supply needed?
No, the relay is mechanical.Are tubes included in the kit?
Yes – PSET-PVC nozzles, PVC tubes and screws.What load can the contact switch?
No more than 1.5 (0.4) A at 250 VAC (VDE 0630).Differential pressure switch | 50-500Pa | changeover contact | 250VAC | IP54 | with PVC tubes and nozzles | Sentera Controls | PSW--500-PVC
Sentera PSW--500-PVC – adjustable differential pressure switch 50–500 Pa with a 250 VAC changeover contact and IP54, with PVC tubes and nozzles – for monitoring filters, fans and heaters in ventilation.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review