  • Modular | digital | smart thermostat with probe | temperature controller | 24-240VAC/DC | -25...+130°C | DIN | Promfactor Baltic | PR FRT12 | 4772151003082

    Code: PR FRT12 24-240VAC/DC
    Barcode: 4772151003082

    Promfactor Baltic FRT12 – a modular digital temperature controller (thermostat) with an external NTC probe, designed for automatic control of heating, cooling and other temperature-sensitive processes. The temperature can be adjusted over a wide −25...+130 °C range, power supply – 24–240 V AC/DC, while the LCD display allows temperature and settings to be monitored. The controller has 2NO relay contacts, adjustable hysteresis, a temperature alarm function and is mounted on a 35 mm DIN rail. 

  • Modular digital thermostat | temperature controller with probe | −25...+130 °C | 24–240 V AC/DC | LCD | 2NO | DIN | IP20 | Promfactor Baltic | FRT12

    Promfactor Baltic FRT12 – a digital microcontroller-based temperature control relay with an external NTC probe, designed for automatic control of heating, cooling and other temperature-sensitive technological processes. A wide −25...+130 °C control range, LCD display, adjustable 1–30 °C hysteresis and an additional temperature alarm function make it possible to maintain the required operating conditions and monitor temperature changes. The controller has two normally open relay contacts, a universal 24–240 V AC/DC power supply and an automatic reset function. Its compact two-module housing is mounted on a standard 35 mm DIN rail, making the thermostat easy to integrate into electrical and industrial automation panels.

    Key point:
    In a heating or cooling system, it is important not only to switch equipment on, but also to know the temperature at a specific point in the process, when it reaches the set limit and when a response to undesirable changes is required. FRT12 combines temperature measurement, automatic relay control and alarm signalling in one modular device. The external NTC probe can be installed separately from the controller, the LCD display allows the temperature to be monitored, and adjustable hysteresis helps prevent excessively frequent switching of heating or cooling equipment.

    ⚡ Spark: Phase, why do you need a digital thermostat with a separate probe and an LCD display? A simple thermostat can also switch a heater on.

    ⚙ Phase: A simple thermostat is suitable for basic temperature maintenance. But when you need to see the actual temperature, regulate across a wider range and have a separate alarm contact, FRT12 provides more control options. It not only controls heating or cooling according to the set temperature, but also allows a response to temperature deviations. The controller itself remains in the electrical panel while the probe measures the temperature at another location.

    Temperature range
    −25...+130 °C
    Power supply
    24–240 V AC/DC
    Control contacts
    2NO | 16 A / 250 V AC
    Control and mounting
    LCD | NTC | DIN 35 mm

    Operating principle

    FRT12 operates on the principle of electronic temperature measurement and relay control. The external NTC temperature sensor responds to changes in ambient or measured-surface temperature by changing its electrical resistance. The controller's microcontroller processes the sensor signal, determines the temperature value and compares it with the parameters set by the user.

    NTC is a negative temperature coefficient thermistor whose resistance decreases as temperature rises. This type of sensor allows temperature to be measured electronically and the data transmitted to the controller. The metal Ø6 × 50 mm probe supplied for FRT12 with a 2.5 m silicone cable allows the temperature measurement point to be separated from the controller located in the electrical panel.

    The temperature control range extends from −25 °C to +130 °C. The desired temperature is set on the controller, while the LCD display shows the actual temperature, settings and operating mode. A 1 °C setting step allows the required temperature value to be selected conveniently.

    Adjustable hysteresis from +1 °C to +30 °C creates a temperature interval between relay ON and OFF conditions. This helps avoid continuous relay contact switching when the measured temperature fluctuates close to the set value. The hysteresis value is selected according to the thermal inertia of the system and the required control stability.

    The controller has a main control relay contact 11–14 and an additional alarm contact 21–24. The main contact can control the heating, cooling or other equipment circuit, while the additional contact is used to transmit a temperature warning signal. The alarm can be integrated into the corresponding indication or automation circuit.

    The automatic reset function allows the controller to return to normal operation when the temperature again meets the configured operating conditions. This function is convenient in systems where temperature deviations may be temporary, but it does not replace separate emergency protection where such protection is required by the technological process.

    Why is this digital thermostat useful?
    FRT12 combines temperature measurement, relay control, digital indication and an additional alarm function in one device. The wide temperature range allows it to be used in different heating and cooling systems, while the external metal NTC probe provides flexibility in selecting the measurement location. The LCD display simplifies maintenance, and adjustable hysteresis allows the control to be adapted to a specific process.

    Technical data

    Product type Digital modular temperature controller / thermal relay
    Brand Promfactor Baltic
    Model PR FRT12 / FRT12
    EAN code 4772151003082
    Control technology Electronic, microcontroller-based
    Supply voltage 24–240 V AC/DC
    Rated frequency 50/60 Hz (for AC supply)
    Power terminals A1, A2
    Temperature control range −25...+130 °C
    Hysteresis range +1...+30 °C
    Temperature correction range −9...+9 °C
    Setting step 1 °C
    Display LCD
    Displayed information Temperature, settings and operating modes
    Relay contact configuration 2NO (two normally open contacts)
    Main control contact terminals 11, 14
    Alarm contact terminals 21, 24
    Contact ratings (AC-1) 16 A / 250 V AC
    Switching power (AC-1) 4000 VA
    DC switching power characteristic 300 W
    Alarm function Temperature deviation alarm
    Automatic reset function Auto-reset
    Temperature measurement terminals T1, T2
    Temperature sensor type NTC thermistor
    Temperature probe material Steel
    Probe dimensions Ø6 × 50 mm
    Sensor cable length 2.5 m
    Sensor cable conductors 2 × 0.3 mm²
    Sensor cable insulation Silicone
    Electrical endurance 100 000 switching operations (10⁵)
    Mechanical endurance 1 000 000 switching operations (10⁶)
    Mounting On 35 mm DIN rail (TH35)
    Number of modules 2 DIN modules
    Connectable conductor cross-section 0.5–2.5 mm²
    Terminal tightening torque 0.5 Nm
    Degree of protection IP20
    Pollution degree 3
    Operating ambient temperature −5...+40 °C
    Storage temperature −10...+50 °C
    Installation altitude above sea level Up to 2000 m
    Standards EN/IEC 60730-1, EN/IEC 60730-2-7

    Main functions

    • Digital temperature control – the microcontroller processes sensor data and controls relay contacts according to the configured temperature conditions.
    • Wide −25...+130 °C range – suitable for various temperature maintenance and control processes.
    • LCD display – allows temperature values, operating modes and settings to be monitored.
    • Adjustable 1–30 °C hysteresis – helps adapt the relay switching frequency to the thermal inertia of the process.
    • Temperature correction ±9 °C – allows the temperature measurement or control value to be corrected.
    • External NTC probe – allows temperature to be measured at a selected location separately from the controller.
    • Steel Ø6 × 50 mm probe – compact temperature measurement element for technical installations.
    • 2.5 m silicone cable – convenient for positioning the temperature sensor farther from the electrical panel.
    • Main relay output – used for heating, cooling or other controlled equipment.
    • Additional alarm contact – provides the option of transmitting a temperature warning signal.
    • Automatic reset – allows the controller to return to normal operation when temperature conditions change.
    • 24–240 V AC/DC supply – suitable for control systems with different supply voltages.
    • DIN mounting – the two-module design is easy to integrate into an electrical automation panel.

    Where is it used?

    • In temperature control systems for electric heaters and heating elements.
    • In electric underfloor heating automation solutions where the control range suits the system application.
    • In temperature maintenance circuits for industrial heating processes.
    • In cooling and refrigeration equipment control systems using relay-based temperature regulation.
    • In temperature monitoring systems for process tanks, reservoirs and equipment.
    • In laboratory equipment temperature control circuits suitable for this type of regulation characteristic.
    • In ventilation and climate-control automation systems.
    • In electrical and automation panels where equipment must be controlled according to temperature measured by an external sensor.
    • In temperature maintenance systems for warehouses, workshops and technical rooms.
    • In heating or cooling processes requiring a separate temperature alarm circuit.

    Use according to need

    For the electrical installer.
    The two-module thermostat is mounted on a 35 mm DIN rail. The external NTC probe is connected to terminals T1 and T2, while the relay outputs are integrated into the temperature control and alarm circuits.
    For the automation designer.
    The wide temperature range, adjustable hysteresis, 2NO contacts and alarm function allow heating and cooling process control solutions to be designed. For higher loads, the thermostat output can control a separate contactor.
    For the maintenance specialist.
    The LCD display allows temperature changes to be monitored directly in the electrical panel, while the additional alarm contact provides the option of transmitting a temperature deviation warning to another indication or automation circuit.

    Practical application

    An electric heating system is installed in an industrial technical room where a set temperature must be maintained and a separate warning signal is required. FRT12 is installed in the electrical automation panel, while the metal NTC temperature probe is positioned at the selected measurement point. For example, +45 °C and a hysteresis suitable for the system are configured in the controller. As the temperature changes, the controller operates the heating circuit through the main relay contact. The additional alarm contact can be used for a temperature deviation warning circuit. The maintenance specialist can see the current temperature on the LCD display and adjust the control parameters. If the heating load exceeds the limits suitable for direct relay switching, a separate contactor is used.

    Advantages

    • Wide temperature control range from −25 °C to +130 °C.
    • Digital control with LCD display.
    • Microcontroller-based temperature control.
    • Adjustable hysteresis from +1 °C to +30 °C.
    • Temperature correction function ±9 °C.
    • External steel NTC probe with silicone cable.
    • Two normally open relay contacts.
    • Separate temperature alarm function.
    • Automatic reset function.
    • Universal 24–240 V AC/DC power supply.
    • Compact two-DIN-module housing.
    • Electrical endurance of 100 000 switching operations and mechanical endurance of 1 000 000 switching operations.

    Limitations

    • IP20 – the controller itself is not suitable for direct exposure to water.
    • The ambient temperature of the device itself must be between −5 °C and +40 °C.
    • A 1 °C setting step is not suitable for systems requiring finer temperature adjustment.
    • The contact load of up to 16 A limits direct control of high-power equipment.
    • Relay ON/OFF control is not analog proportional power regulation.
    • One main control output is not intended for controlling several independent temperature zones.
    • Automatic reset is not a separate manually resettable emergency overtemperature protection.

    Installation and safety notes

    • Electrical connection. Installation and connection of the controller must be carried out by a qualified electrical specialist after disconnecting the power supply and verifying absence of voltage.
    • DIN rail mounting. FRT12 is mounted on a standard 35 mm DIN rail in an electrical or automation panel. The housing occupies two DIN modules.
    • Power terminals A1 and A2. The controller is supplied with 24–240 V AC/DC in accordance with the device wiring diagram.
    • NTC sensor connection. The temperature sensor is connected to measurement terminals T1 and T2. The measurement circuit must be properly separated from power circuits.
    • Sensor placement. The probe is installed where the temperature best represents the controlled process. Incorrect positioning may cause inaccurate temperature regulation.
    • Steel probe mounting. The Ø6 × 50 mm measuring element must be fixed so that good thermal contact is provided with the measured medium or surface where such a measuring method is intended by the system.
    • Sensor cable protection. The 2.5 m silicone cable must not be mechanically damaged, crushed or routed over sharp structural edges.
    • Relay output purpose. The main control contact is connected through terminals 11 and 14, while the alarm contact is connected through terminals 21 and 24.
    • Contact load. The 16 A / 250 V AC rating applies under the corresponding AC-1 load conditions. Inductive loads and equipment with high starting currents require an appropriate power switching solution.
    • Higher-power heating. If the load exceeds the permitted thermostat relay limits, a contactor or other suitable power switching device is used.
    • Temperature limits. −25...+130 °C is the temperature control range, while the operating ambient temperature of the controller itself is −5...+40 °C.
    • Hysteresis setting. Too little hysteresis may cause frequent switching, while a large value may produce wider temperature fluctuations. The value should be selected according to the process inertia.
    • Emergency protection. The temperature control relay must not be used as the only protection in processes where overheating may endanger people or equipment.
    • IP20. The controller must be installed in an electrical panel with a suitable degree of protection, protected from water and unacceptable environmental exposure.
    • Connectable conductor cross-section. Use 0.5–2.5 mm² conductors and tighten the terminals to 0.5 Nm.
    • Functional check. After installation, verify temperature measurement, operation of the relay outputs and response of the temperature alarm.
    ⚡ Phase tip:
    When installing FRT12, it is important to select not only the correct temperature setting but also the correct NTC probe location. If the sensor is too close to the heating element, it may respond to local temperature that does not represent the overall operating conditions of the system. Also separate temperature control and emergency protection functions: the main relay contact is intended for equipment control, while the alarm contact is intended for transmitting a temperature deviation signal. In systems with high thermal inertia, properly selected hysteresis helps reduce unnecessary ON/OFF cycles.

    Quick selection guide

    −25...+130 °C
    24–240 V AC/DC
    LCD | 2NO | 16 A
    NTC | DIN | IP20
    Suitable when you need:
    • digital temperature control over a wide −25...+130 °C range
    • temperature monitoring on an LCD display
    • relay control of heating or cooling equipment
    • a separate temperature alarm contact
    • adjustable 1–30 °C hysteresis
    • an external NTC probe with a 2.5 m cable
    • a modular device for installation in an electrical panel
    Evaluate before use:
    • whether the process temperature falls within the −25...+130 °C control range
    • whether the 1 °C setting step is suitable for the required temperature control
    • whether the load current and load type are compatible with the relay contacts
    • whether the NTC probe can be correctly installed at the intended location
    • whether additional independent overtemperature protection is required
    • whether there is space in the electrical panel for two DIN modules
    Important reminder: FRT12 is a temperature control and alarm device, not a circuit breaker or an independent emergency temperature limiter. The 16 A contact rating depends on the load category. Suitable electrical protection must be provided for heating and cooling equipment.

    FAQ – Spark asks, Phase answers

    ⚡ Spark: How is FRT12 different from a simple modular thermostat?
    ⚙ Phase: FRT12 has an LCD display, a wide −25...+130 °C temperature control range, adjustable hysteresis, a temperature correction function and an additional alarm contact. This allows it not only to maintain temperature, but also to monitor its value and transmit a warning signal.
    ⚡ Spark: Does −25...+130 °C mean that the thermostat itself can be installed at +130 °C?
    ⚙ Phase: No. This is the temperature control range associated with the measurement system. The permitted operating ambient temperature of the FRT12 controller itself is from −5 °C to +40 °C. The controller is therefore installed in an electrical panel while temperature is measured with the external probe.
    ⚡ Spark: What is meant by a capillary probe and why is it useful?
    ⚙ Phase: This model uses an external NTC temperature probe with a metal Ø6 × 50 mm measuring element and a 2.5 m silicone cable. It allows the temperature measurement point to be located separately from the controller mounted on the DIN rail. Temperature is transmitted by an electrical sensor signal.
    ⚡ Spark: Why is adjustable hysteresis from +1 °C to +30 °C required?
    ⚙ Phase: Hysteresis defines the temperature difference between the relay switching thresholds. A smaller hysteresis allows a narrower temperature interval to be maintained, while a larger one helps reduce the number of relay switching operations when the process has high thermal inertia.
    ⚡ Spark: Why does the thermostat need two relay contacts?
    ⚙ Phase: One contact is used for the main temperature control circuit and the other for the alarm. The main contact terminals are 11–14 and the alarm terminals are 21–24. This makes it possible to control equipment and transmit a temperature warning signal separately.
    ⚡ Spark: Can FRT12 be used for both heating and cooling?
    ⚙ Phase: Yes, FRT12 can be used in temperature control systems with heating or cooling equipment. The specific ON/OFF logic and relay connection are selected according to the diagram of the controlled process.
    ⚡ Spark: Can the thermostat directly control a 3 kW electric heater?
    ⚙ Phase: If the heater is a suitable resistive load and its operating current does not exceed the permissible relay contact limits, direct control may be possible. A separate contactor is used for higher or more complex loads.
    ⚡ Spark: Does the device require a 230 V supply?
    ⚙ Phase: No. FRT12 supports a 24–240 V AC/DC supply range. This allows the device to be used in both 24 V and 230 V automation systems in accordance with its power connection requirements.
    ⚡ Spark: What is the purpose of the automatic reset function?
    ⚙ Phase: Auto-reset allows the controller to return automatically to normal operation when the temperature conditions again meet the configured parameters. This is convenient for processes where temporary temperature deviations are possible. However, a separate protection circuit may be required for emergency overheating shutdown.
    ⚡ Spark: Can the FRT12 temperature probe be installed farther away from the controller?
    ⚙ Phase: Yes. The external NTC sensor has a 2.5 m silicone cable, allowing the temperature measurement point to be separated from the electrical panel. The cable should be routed so that it is protected from damage and electromagnetic interference.
    ⚡ Spark: Is FRT12 suitable for professional industrial automation systems?
    ⚙ Phase: Yes. It can be used in temperature measurement and control circuits requiring a digital controller with a relay output, additional alarm contact and external sensor. It is especially convenient when the temperature needs to be monitored in the electrical panel but measured at another location in the equipment.

    Promfactor Baltic FRT12 – digital temperature controller with NTC probe and LCD display

    PR FRT12 modular digital temperature control relay for automatic control of heating, cooling and other temperature-sensitive processes. −25...+130 °C control range, 24–240 V AC/DC power supply, LCD display, 1–30 °C hysteresis, ±9 °C temperature correction, two normally open relay contacts and temperature alarm function. The external Ø6 × 50 mm steel NTC probe with a 2.5 m silicone cable allows temperature to be measured separately from the controller. Automatic reset, 35 mm DIN mounting, two-module housing and IP20 degree of protection – a functional solution for temperature control systems in residential, commercial and industrial facilities.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.