Directional reflector halogen lamp PAR38 E27 | 120W | 24V | 1545lm | 2700K | Philips
Code: 80739Price 13.48 € VAT incl.( 11.14 € VAT excl. )A reflector lamp is a specialized light source designed for both professional and household use when a concentrated light beam is required. It is distinguished by high light intensity, universal installation, and natural color rendering (CRI 100), making it ideal for both targeted lighting and technical applications in industry or specialized environments.
The lamp can be used in lighting systems designed by engineers, in projects carried out by electricians, as well as in private households, garages, workshops, or even stage lighting.
-
Technical Specifications
Lamp type: PAR38, pressed glass reflector lamp
Base: E27
Voltage: 24 V
Power: 120 W
Luminous flux: ~1545 lm
Light color: 2700 K (warm white)
Color rendering (CRI): 100 – natural color reproduction
Beam angle: 10° (narrow, concentrated beam)
Service life: ~2000 h
Switching cycles: 8000
Dimmable: Yes (compatible with dimmers)
Dimensions: ∅121 mm
Operating position: Universal (any)
Energy consumption: 127 kWh/1000 hFunctions
Creates a concentrated light beam (10°), suitable for accent or stage lighting.
High CRI 100 ensures accurate color reproduction, ideal for exhibitions, showcases, galleries.
Dimmable – brightness can be adjusted as needed.
Universal installation – E27 socket fits most standard luminaires.
Applications
Household: Garages, workshops, yards, gardens where strong spot lighting is needed.
For engineers: Designing specialized lighting systems requiring precise beams and natural colors.
For electricians: Easy installation in existing fixtures, suitable for industrial sites, stages, exhibitions.
Commercial spaces: Shops, galleries, showcases, stage lighting.
Pros
Narrow 10° beam – perfect for accent lighting.
High color rendering (CRI 100).
Universal installation (E27 base, any position).
Dimmable – adjustable brightness.
Strong luminous flux – nearly 1550 lm.
Cons
High energy consumption (127 kWh/1000 h).
Designed for 24 V – requires suitable transformer or system.
♻ The efficient choice – LED equivalent
Same base, similar light and up to 79% less electricity: 120 W → 25 W, i.e. ≈ 95 kWh less per 1,000 operating hours.
LED equivalents:
⚠ The LED equivalent gives less light – if you need the same brightness, contact us.
Published: 2026-10-29
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThe IP protection class indicates the device's resistance to environmental factors.

The first digit indicates protection against dust and solid objects.
The second digit indicates protection against moisture.First digit values:
X — Untested;
0 — No protection;
1 — Protected against solid objects larger than 50 mm;
2 — Protected against solid objects larger than 12.5 mm;
3 — Protected against solid objects larger than 1 mm;
4 — Protected against solid objects larger than 1 mm;
5 — Dust protected;
6 — Totally dustproof.
Second digit values:X — Untested;
0 — No protection;
1 — Protected against vertically falling water drops;
2 — Protected against water drops falling at a 15º angle;
3 — Protected against rain falling at a 60º angle;
4 — Protected against water splashes;
5 — Protected against water jets;
6 — Protected against large amounts of water;
7 — Protected against short-term immersion in water up to 1 meter deep;
8 — Protected against long-term immersion in water up to 3 meters deep.Lumen (lm) – unit of luminous flux: how much light a lamp or luminaire emits in total. Lux (lx) – illuminance: how much of that light falls on 1 m² of surface (1 lx = 1 lm/m²). Watts (W) only show power consumption – compare LED brightness by lumens.
How many lux does a room need?
Corridor, storeroom, basement 100–150 lx Living room, bedroom 100–300 lx Garage, warehouse 100–200 lx Kitchen, bathroom, desk 300–500 lx Office, computer workstation 500 lx Workshop, fine work 500–750 lx How to calculate the lumens you need
Required lumens ≈ illuminance (lx) × area (m²) ÷ 0.5
The 0.5 factor accounts for light absorbed by walls, ceiling and diffusers and for luminaires getting dirty over time. Example: 18 m² garage, 200 lx → 200 × 18 ÷ 0.5 = 7,200 lm. That is about three 150 cm T8 LED tubes of ~2,500 lm each.
This is an estimate. For an exact design (workplaces, production, public areas) use lighting calculation software, e.g. DIALux.
Recommended values are indicative, based on the principles of EN 12464-1 for workplace lighting.
3 main types of white light:
Warm white (2700 - 3000 K)
Neutral white / daylight (4000 - 4500 K)
Cool white (5000 - 6500 K)
How to choose the right light color temperature:2700 - 3000K creates a cozy atmosphere in a room. Used in spas, hotel entrances, living rooms, and bedrooms.
4000 - 4500K is used in commercial, retail, office spaces, garages, medical buildings, as well as bathrooms, kitchens, and workrooms.
5000 - 6500K is suitable for lighting workshops, operating rooms, or other areas where attention to detail is important. Also suitable for outdoor lighting, modern interiors, and their accents.
To calculate how many and what type of light fixtures are needed for your desired space, visit this website: https://www.dialux.com/en-GB/download.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Directional LED bulb PAR30 | E27 | 25 W | 2400 lm | 2700K | 30° | black | OPTONICA | SP25-A2 | 1530Code: SP25-A2-1530Directional PAR30 LED bulb E27: 25 W, 2400 lm, 2700K, 30°, black body.
Price 33.99 € VAT incl.( 28.09 € VAT excl. )Directional reflector LED lamp E27 | 7W | 230V | 667lm | 2700K | PhilipsCode: 84088Philips CorePro LEDspot Reflectors – LED lamps designed as a direct replacement for halogen and incandescent lamps. With their versatile design and E27 base, these LED lamps easily fit most fixtures, providing professional lighting in homes, offices, and commercial spaces.
Price 7.60 € VAT incl.( 6.29 € VAT excl. )