Fire-resistant halogen-free cable | (N)HXH-J 3×6 RE FE180/E90 | 0.6/1 kV | VdS | orange | Prakab FABER
Code: NHXH-J-3X6-FE180-E90Price 5.99 € VAT incl.( 4.95 € VAT excl. )(N)HXH-J 3×6 RE FE180/E90 – fire-resistant halogen-free copper cable, 0.6/1 kV, VdS and VDE-REG marked, for lines that must work during a fire. Sold by the metre.
-
Fire-resistant halogen-free cable | (N)HXH-J 3×6 RE FE180/E90 | 0.6/1 kV | VdS | orange | Prakab FABER
(N)HXH-J 3×6 RE FE180/E90 is a three-core halogen-free copper cable. During a fire the insulation stays intact for 180 minutes (FE180), and the cable system maintains its function for 90 minutes (E90). The cable is designed for lines that must work during a fire: smoke extraction, fire pumps, emergency lighting. Made by Prakab, FABER brand, VDE and VdS marked.
Key idea:
During a fire an ordinary cable burns through within minutes, and the smoke extraction fan or fire pump stops. An FE180/E90 cable installed with certified fixings keeps the supply for as long as needed for evacuation and firefighters’ work. The 3×6 mm² cross-section suits more powerful single-phase loads or longer lines where voltage drop matters.Conductors
3 × 6 mm², solid (RE)Insulation in fire
FE180 – 180 min.System function
E90 – 90 min.Voltage
0.6/1 kVOperating principle
The cable consists of three solid copper conductors: phase (brown), neutral (blue) and protective PE (green-yellow). The insulation keeps its insulating properties in fire, and the orange sheath is made of a halogen-free compound. The colour helps to identify fire safety lines on the route at once.
FE180 means that the cable insulation stays intact in direct flame for 180 minutes. E90 means that the whole cable system (the cable with tested fixings and trays) maintains circuit function for 90 minutes according to DIN 4102-12.
When burning, the sheath gives off little smoke and releases no corrosive halogen acids, so visibility in escape routes lasts longer and equipment is not damaged.
Why choose the (N)HXH-J 3×6 FE180/E90?
It meets the requirements of fire safety projects for lines that must work during a fire. VdS and VDE-REG marking is confirmed by independent institutions, which makes the documents needed for building handover simpler.Technical specifications
Product type Fire-resistant halogen-free power cable Manufacturer / brand Prakab / FABER Designation (N)HXH-J 3×6 RE FE180/E90 0.6/1 kV Number of cores and cross-section 3 × 6 mm² (L, N, PE) Conductors Copper, solid, round (RE) Core colours Green-yellow, blue, brown Sheath Halogen-free, orange Rated voltage U0/U 0.6/1 kV Insulation integrity in fire FE180 – 180 min. (IEC 60331) System circuit integrity E90 – 90 min. (DIN 4102-12, with a tested fixing system) Fire behaviour Halogen-free (EN 60754), low smoke (EN 61034) Min. bending radius 12 × cable diameter Certificates / marking VDE-REG 8310, VdS, CE, year of manufacture 2022 Length marks Metre marks on the sheath Main functions
- FE180 – the insulation stays intact in fire for 180 min., so the circuit does not short during a fire.
- E90 with a certified system – fire safety equipment is supplied for 90 min.
- Halogen-free, low smoke – no corrosive gases when burning, visibility stays in escape routes.
- Orange sheath – fire safety lines are clearly visible and easy to identify on the route.
- 3×6 mm² cross-section – lower voltage drop on long lines and for higher loads.
- VdS and VDE-REG – quality confirmed by independent institutions for building documentation.
- Metre marks – easy to calculate the remaining and used length.
Where is it used?
- Supply of smoke extraction fans and dampers
- Supply of fire pump stations and sprinkler systems
- Emergency and escape lighting lines
- Supply of firefighter lifts
- Supply of fire alarm and voice alarm panels
- Hospitals, shopping centres, high-rise buildings, tunnels
- Underground car parks
Use by need
For fire safety system installers.
A VdS certified FE180/E90 cable from stock, without waiting for a factory order.For designers.
A clear, standardised solution for E90 lines with higher loads.For construction contractors.
Easier building handover: the cable marking matches fire protection system documentation.Practical use
If a group of smoke extraction dampers in a shopping centre needs a single-phase line from the fire safety panel that must work for 90 minutes in a fire, the (N)HXH-J 3×6 RE FE180/E90 is laid on E90 certified metal clips or trays. The 6 mm² cross-section keeps the voltage drop within limits even on a long route.Pros
- FE180 insulation integrity
- E90 system circuit integrity
- Halogen-free, low smoke
- VdS and VDE-REG 8310 marking
- Orange sheath – easy to identify
- Metre marks on the sheath
Cons / limitations
- E90 is valid only with a tested fixing system – plastic clips are not suitable
- More expensive than ordinary halogen-free cable – where function in fire is not needed, choose N2XH
- For single-phase lines – for three-phase choose the 5-core version
- Solid conductors – not suitable for flexible connections
Safety and installation notes
- E90 class is ensured only with a fixing system tested together with this cable – check clip spacing and type in the system certificate.
- Do not fix to structures that will collapse earlier than the cable system itself in a fire.
- Do not go below the minimum bending radius (12 × diameter) so as not to damage the insulation.
- Join lines only in junction boxes with a circuit integrity class.
- In the design, consider voltage drop, as conductor resistance increases during a fire.
Quick selection guide
3×6 mm² REFE180 / E900.6/1 kVHalogen-freeVdSSuitable when you need:- a line that works during a fire (E90);
- single-phase supply for more powerful fire safety loads;
- halogen-free cable with VdS certificate.
Check before use:- whether you have an E90 certified fixing system;
- the circuit integrity duration required by the project (E30 / E90);
- the voltage drop along the whole route.
Important reminder: The cable alone does not provide E90 class – it is provided only by the whole system installed with tested fixings.FAQ
What is the difference between FE180 and E90?
FE180 describes the fire resistance of the cable insulation (180 min.), and E90 the circuit integrity of the whole cable system (90 min.).What does (N)HXH-J mean?
H – halogen-free materials, X – cross-linked insulation, J – with green-yellow PE conductor; (N) – design based on DIN VDE 0266 with minor deviations.Can it be fixed with plastic clips?
No, an E90 system requires tested metal clips or trays.What does the VdS marking mean?
The product has been tested and certified by VdS, an independent German fire protection institution.Do you sell by the metre?
Yes, we cut the required length from the drum.Can I pick it up in Šiauliai?
Yes, you can pick up the cable at our office at J. Basanavičiaus g. 23, Šiauliai.(N)HXH-J 3×6 RE FE180/E90 0.6/1 kV – fire-resistant cable
Three-core solid copper halogen-free cable with an orange sheath. Insulation stays intact in fire for 180 min. (FE180), system function for 90 min. (E90), VDE-REG 8310 and VdS marked. Designed for smoke extraction, fire pumps, emergency lighting and other lines that must work during a fire.
Published: 2026-11-17 · Data verified against the cable marking and FE180/E90 requirements: 2026-11-17
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review




