Products catalog

  • High-frequency Rogowski coil | up to 10 MHz | Ø50 mm | up to 500 kA | 2 m cable | H-FCT-200

    Code: ESH-FCT-200

    A high-frequency Rogowski current measurement coil designed for measuring very fast-changing and pulsed AC currents where standard Rogowski coils or current transformers can no longer accurately reproduce the signal. Thanks to its wide frequency bandwidth of up to 10 MHz, this coil is suitable for laboratory research, power electronics testing, pulsed current analysis, and EMC/EMI measurements. The flexible design allows safe and non-invasive installation around the conductor, while the small cross-section enables operation even in limited-space test setups. 

  • Technical Specifications

    Type: High-frequency Rogowski current measurement coil
    Model: H-FCT-200
    Coil length: 200 mm
    Inner window diameter: 50 mm
    Cross-section: 8 mm
    Rated input current: up to 500 kA
    Output transfer ratio: 1.2 mV/kA @ 50 Hz
    Accuracy: ±5% (uncalibrated, temperature drift ~200 ppm/°C)
    Linearity: ±0.2% (from 2% to 100% of rated current)
    Frequency bandwidth: 1 kHz – 10 MHz
    Cable length: 2 m
    Measurement type: Alternating and pulsed current (AC, HF)

    Functions

    High-frequency current measurement up to 10 MHz
    Detection of pulsed and extremely high currents (up to 500 kA)
    Non-invasive measurement – no need to interrupt the circuit
    Wide linear operating range
    Flexible construction for easy installation

    Applications

    Electronics and power engineers: Suitable for analysis of IGBTs, MOSFETs, inverters, switching power supplies, capacitor discharges, short pulses, and switching transients.
    Laboratories and test benches: Used in high-voltage and high-current tests in university and industrial laboratories where very fast current response is required.
    Industrial diagnostics and specialized measurements: Suitable for EMC/EMI testing and monitoring explosive or pulsed processes where current levels and frequencies exceed standard measurement limits.

    Pros

    Extremely wide frequency bandwidth – up to 10 MHz
    Capability to measure very high pulsed currents (up to 500 kA)
    Non-invasive and safe measurement
    Flexible and compact design
    Ideal for laboratory and R&D applications

    Cons

    Uncalibrated coil – individual calibration may be required for higher accuracy
    Not intended for standard energy metering
    Requires an external integrator or oscilloscope for signal processing 

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.