  • Frequency inverter | 3-phase 400 V | 1.5 kW HD / 2.2 kW ND | 4.0 / 5.1 A | C3 EMC filter | potentiometer | IP20 | LS G100 LSLV0015G100-4EOFN

    Code: LSLV0015G100-4EOFN

    LS G100 series frequency inverter for 3-phase 400 V motors: 1.5 kW / 4.0 A heavy duty or 2.2 kW / 5.1 A for pumps and fans. 3-phase 380–480 V supply only. Built-in C3 EMC filter, keypad speed potentiometer, PID with sleep / wake-up, RS-485 Modbus RTU. IP20, panel mounting. Direct replacement for the SV015iG5A-4 (iG5A).

  • Frequency inverter | 3-phase 400 V | 1.5 kW HD / 2.2 kW ND | 4.0 / 5.1 A | C3 EMC filter | potentiometer | IP20 | LS G100 LSLV0015G100-4EOFN

    LS ELECTRIC G100 series frequency inverter for 3-phase 400 V induction motors up to 1.5 kW in heavy duty and 2.2 kW in normal duty (pumps, fans). It connects to a 3-phase 380–480 V supply, controls motor speed in the 0–400 Hz range and has a built-in C3 EMC filter and a speed potentiometer on the keypad.

    Key point:
    A simple way to control a 400 V motor's speed without extra accessories: the filter and potentiometer are built in, Modbus RTU comes as standard. Suitable for new machines and for replacing an old SV015iG5A-4 (iG5A) of the same power with a proven, widely used solution.
    Motor power
    1.5 kW HD / 2.2 kW ND
    Supply
    3-ph 380–480 V, 50/60 Hz
    Output current
    4.0 A HD / 5.1 A ND
    Built in
    C3 EMC filter + potentiometer

    Operating principle

    The inverter is mounted on the back plate of a control panel: the supply goes to terminals R, S, T, the motor to U, V, W. The motor is connected in star for 400 V (check the motor nameplate).

    Inside, the supply voltage is rectified and converted back to three-phase by IGBT modules, now with adjustable frequency and voltage. Speed is set with the keypad potentiometer (VOLUME), an external 0–10 V / 4–20 mA signal, digital inputs or via RS-485 Modbus RTU.

    The result: soft starting without inrush current, exactly the speed you need, and lower energy use for pumps and fans whose power depends strongly on speed.

    Why choose LSLV0015G100-4EOFN?
    Two power ratings in one unit: 1.5 kW with 150 % overload for heavy duty (conveyors, mixers) or 2.2 kW with 120 % overload for pumps and fans. The built-in C3 filter reduces interference in industrial environments without a separate filter.

    Technical specifications

    Product type Frequency inverter for 3-phase induction motors
    Manufacturer / series LS ELECTRIC (LSIS), G100
    Order code LSLV0015G100-4EOFN
    Previous generation equivalent SV015iG5A-4 (iG5A series)
    Supply voltage 3-ph 380–480 V AC (−15 % … +10 %), 50/60 Hz (±5 %)
    Output 3-ph, 0–400 Hz (sensorless vector mode – up to 120 Hz)
    Motor power HD 1.5 kW (2 HP) / ND 2.2 kW (3 HP)
    Rated output current HD 4.0 A / ND 5.1 A
    Input current HD 4.2 A / ND 5.5 A
    Overload HD 150 % – 1 min / ND 120 % – 1 min
    Control methods V/f, slip compensation, sensorless vector control
    Speed reference Keypad potentiometer (VOLUME), analogue inputs (voltage / current), digital inputs, RS-485
    Communication RS-485 Modbus RTU (S+/S−) and RJ45 port; optional modules: Ethernet (RAPIEnet+, EtherNet/IP, Modbus TCP), Profibus-DP, CANopen
    EMC filter Built-in, category C3 to EN 61800-3
    Braking B1/B2 terminals for an external braking resistor (recommended 300 Ω, 300 W)
    Protection class IP20 (UL Open); UL Type 1 kit – optional
    Operating temperature HD −10…+50 °C / ND −10…+40 °C
    Storage temperature −20…+65 °C
    Relative humidity up to 95 %, non-condensing
    Altitude up to 1000 m; 1000–4000 m – derate current and voltage by 1 % per 100 m
    Vibration ≤ 9.8 m/s² (1 G)
    Weight 1.44 kg
    Compliance CE, UL 61800-5-1, EN 61800-3

    Main functions

    • Built-in C3 EMC filter – less interference with other equipment and no separate filter in the panel.
    • Keypad potentiometer – speed can be adjusted by hand right after connection, with no external control.
    • PID controller with sleep / wake-up – the pump holds pressure and stops by itself when no water is drawn.
    • HD / ND modes – one inverter for 1.5 kW heavy load or a 2.2 kW pump or fan.
    • Modbus RTU as standard – easy connection to a PLC, SCADA or building management system.
    • Sensorless vector control – more torque at low speed without an encoder.
    • Braking resistor connection – faster stopping of high-inertia machines.

    Where is it used?

    • Circulation and pressure booster pumps (2.2 kW in ND mode)
    • Ventilation and smoke extraction fans
    • Conveyors and transporters in production
    • Mixers, dosing units, packaging equipment
    • Grain dryers and storage ventilation on farms
    • Drilling, grinding and woodworking machines
    • Replacing old LS iG5A (SV015iG5A-4) inverters

    Use by need

    Automation integrator.
    Modbus RTU as standard plus optional Ethernet / Profibus / CANopen modules let you add the drive to a PLC or SCADA without extra gateways.
    Plant energy engineer.
    Replaces an old iG5A with a new-generation unit of the same power and reduces the energy use of pumps and fans.
    Farm or homestead owner.
    The keypad potentiometer lets you set fan or pump speed by hand with no programming, provided a 3-phase 400 V supply is available.

    Practical use

    If a 2.2 kW fan in a farm grain store always runs at full speed and is noisy, this inverter in ND mode lets you reduce the speed to the airflow actually needed: fan power falls roughly with the cube of speed, so even 20 % lower speed noticeably cuts energy consumption.

    Pros

    • Built-in C3 EMC filter and potentiometer
    • Two power ratings: 1.5 kW HD / 2.2 kW ND
    • Modbus RTU and RJ45 port as standard
    • PID with sleep / wake-up for pumps
    • Wide input voltage range 380–480 V
    • Direct replacement for the old SV015iG5A-4

    Cons / limitations

    • 3-phase 380–480 V supply only – a 1-phase 230 V supply needs a different model
    • IP20 – panel mounting only; damp environments need an IP66 inverter
    • Braking resistor not included, ordered separately
    • Ethernet, Profibus and CANopen only with optional modules

    Safety and installation notes

    • Before work, disconnect the supply and wait until the DC bus capacitors discharge (see the manufacturer's manual).
    • Mount the inverter vertically and leave free space above and below for cooling.
    • Do not place a contactor between the inverter and motor that switches the motor off while the inverter is running.
    • Connect the motor with a shielded cable and earth the shield at both ends so the EMC filter works.
    • Protect the inverter with a circuit breaker or fuses as recommended by the manufacturer.
    • Connect protective earth (PE) before switching on the supply.

    Quick selection guide

    3-ph 380–480 V
    1.5 kW HD | 4.0 A
    2.2 kW ND | 5.1 A
    EMC C3 | IP20
    Modbus RTU
    Suitable when you need to:
    • control the speed of a 400 V 3-phase motor up to 2.2 kW
    • replace an old SV015iG5A-4
    • connect the drive to a PLC via Modbus RTU
    • save energy on pumps and fans
    Check before use:
    • that the supply is 3-phase 380–480 V (not 1-phase 230 V)
    • the motor rated current: HD up to 4.0 A, ND up to 5.1 A
    • that the motor is connected in star for 400 V
    • that there is enough cooling space in the panel
    Important reminder: a frequency inverter does not replace the circuit breaker in front of it and cannot turn a 1-phase 230 V supply into a 3-phase 400 V one.

    FAQ

    Can it be connected to a 1-phase 230 V supply?
    No, this model is for a 3-phase 380–480 V supply only.
    What motor size will it control?
    Up to 1.5 kW in heavy duty (4.0 A) or up to 2.2 kW for a pump or fan (5.1 A).
    Does it replace the SV015iG5A-4?
    Yes, it is the new-generation G100 equivalent of the same power.
    Is an additional EMC filter needed?
    No, a category C3 filter is already built in.
    Can speed be set without the keypad buttons?
    Yes, with the keypad potentiometer or an external 0–10 V / 4–20 mA signal.
    Can it be installed outdoors?
    No, the IP20 inverter must be installed inside a closed panel.

    Frequency inverter | 3-phase 400 V | 1.5 kW HD / 2.2 kW ND | 4.0 / 5.1 A | C3 EMC filter | potentiometer | IP20 | LS G100 LSLV0015G100-4EOFN

    LS G100 LSLV0015G100-4EOFN – a 3-phase 400 V frequency inverter for 1.5 kW (HD) / 2.2 kW (ND) motors with a built-in C3 EMC filter, potentiometer and Modbus RTU; a direct replacement for the SV015iG5A-4 for pumps, fans and conveyors.

    Published: 2026-11-20 · Data verified against the manufacturer's datasheet: 2026-11-20

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Three-phase frequency inverter | 1,5 kW | 4A | 400VAC | IP66 | with EMC filter | designed for controlling three-phase motors | EP66-0015T3 Eura Drives
    Code: EP66-0015T3

    Three-phase frequency inverter designed to control the speed, direction, and torque of asynchronous three-phase electric motors. It features a high IP66 protection rating, making it suitable for demanding environments — in industry, as well as in ventilation, pumping, conveyor, or refrigeration systems where resistance to dust, moisture, and temperature fluctuations is essential.

    Thanks to its compact design and integrated EMC filter, the frequency inverter is ideal for both professional electricians and engineers designing modern automated systems. 

    Price 426.74 € VAT incl.