  • Halogen-free power cable | N2XH-J 5×4 RE | 0.6/1 kV | Cu | XLPE | black | Prakab

    Code: N2XH-J-5X4-RE

    N2XH-J 5×4 RE – halogen-free five-core copper power cable with XLPE insulation, 0.6/1 kV, for three-phase lines in public buildings. Sold by the metre.

  • Halogen-free power cable | N2XH-J 5×4 RE | 0.6/1 kV | Cu | XLPE | black | Prakab

    N2XH-J 5×4 RE is a five-core copper power cable with XLPE insulation and a halogen-free sheath, rated voltage 0.6/1 kV. It is designed for three-phase 400 V lines in buildings where, in case of fire, it is important to have as little smoke as possible and no corrosive gases. Manufacturer – Prakab, the cable is VDE marked.

    Key idea:
    When burning, PVC cable gives off dense smoke and hydrochloric acid fumes. They hinder evacuation and corrode equipment. The N2XH sheath contains no halogens, so it is chosen for schools, hospitals, shopping centres, data centres and escape routes. XLPE insulation lets the conductor reach 90 °C, so a cable of the same cross-section can carry more current than an ordinary PVC cable.
    Conductors
    5 × 4 mm², solid (RE)
    Voltage
    0.6/1 kV
    Sheath
    Halogen-free, low smoke
    Conductor temperature
    up to 90 °C

    Operating principle

    The cable consists of five solid copper conductors (class 1, RE) insulated with cross-linked polyethylene (XLPE, code “2X”). One of them is a green-yellow protective PE conductor (code “J”). Three phases, neutral and PE are in one cable, so it can supply a three-phase load in a TN-S system.

    The outer sheath (code “H”) is made of a halogen-free compound. When burning it gives off little smoke and releases no corrosive halogen acids. In addition, a single installed run does not propagate flame.

    XLPE insulation continuously withstands a conductor temperature of 90 °C, and up to 250 °C during a short circuit. This gives the cable a reserve for higher loads and short-circuit currents.

    Why choose the N2XH-J 5×4?
    It is a single cable for a three-phase line with neutral and PE, suitable for buildings where halogens are prohibited by fire safety requirements. PVC cable would not be enough, and a more expensive fire-resistant cable is not needed.

    Technical specifications

    Product typeHalogen-free power cable
    ManufacturerPrakab
    DesignationN2XH-J 5×4 RE 0.6/1 kV
    Number of cores and cross-section5 × 4 mm² (with green-yellow PE conductor)
    ConductorsCopper, solid, round (RE, class 1)
    InsulationCross-linked polyethylene (XLPE)
    SheathHalogen-free, black
    Rated voltage U0/U0.6/1 kV
    Max. conductor temperature90 °C (250 °C during short circuit)
    Min. bending radius12 × cable diameter
    StandardDIN VDE 0276-604
    Fire behaviourHalogen-free (EN 60754), low smoke (EN 61034), flame retardant (EN 60332-1)
    MarkingVDE, CE, year of manufacture 2021

    Main functions

    • Halogen-free sheath – no hydrochloric acid fumes when burning, which corrode electronics and metal structures.
    • Low smoke – better visibility in escape routes during a fire.
    • XLPE insulation, 90 °C – higher current rating and overload resistance than PVC cable.
    • 5 cores with PE – a complete three-phase TN-S line in one cable.
    • Solid conductors (RE) – convenient and reliable clamping in terminals, no ferrules needed.
    • 0.6/1 kV – insulation reserve for a 400 V network, suitable for distribution lines.

    Where is it used?

    • Schools, kindergartens, hospitals, care homes
    • Shopping and office centres, hotels
    • Escape routes, staircases, corridors
    • Data centres and server rooms
    • Underground car parks, tunnels
    • Three-phase lines to panels, supply of ventilation and heating equipment
    • In cable trays, conduits, on walls and ceilings

    Use by need

    For electrical contractors.
    The halogen-free cable specified in the project is available at once from stock in Šiauliai, without waiting for an order.
    For designers.
    A cable standardised to DIN VDE 0276-604 for three-phase lines in public buildings.
    For building facility managers.
    When renovating lines, the building’s fire safety improves while the investment is lower than with fire-resistant cables.

    Practical use

    If a school ventilation unit needs a three-phase line from the main panel through a corridor, and the project requires halogen-free cable, the N2XH-J 5×4 RE is laid in a cable tray along the whole route. Three phases, N and PE are in one cable, and the corridor will not fill with corrosive smoke in case of fire.

    Pros

    • Halogen-free, low smoke
    • XLPE insulation, 90 °C conductor temperature
    • 0.6/1 kV rated voltage
    • 5 cores with PE – a complete three-phase line
    • VDE marked, DIN VDE 0276-604
    • In stock, any length available

    Cons / limitations

    • No circuit integrity in fire (not FE180/E90) – for fire safety systems choose (N)HXH FE180/E90
    • Solid conductors – not suitable for flexible connections
    • Stiffer than PVC cable – plan the route with the bending radius in mind

    Safety and installation notes

    • Choose line protection according to the installation method, route length and voltage drop, not only by cross-section.
    • Do not install at ambient temperatures below −5 °C, as the sheath may crack.
    • Do not go below the minimum bending radius (12 × diameter).
    • The green-yellow conductor is used only as PE.
    • Tighten conductor ends with the torque specified by the terminal manufacturer.

    Quick selection guide

    5×4 mm² RE
    0.6/1 kV
    XLPE, 90 °C
    Halogen-free
    Suitable when you need:
    • a three-phase line with N and PE in a public building;
    • halogen-free cable according to the project;
    • fixed installation indoors.
    Check before use:
    • the CPR reaction-to-fire class required by the project;
    • the current rating for the installation method;
    • whether the line needs circuit integrity in fire (E30/E90).
    Important reminder: N2XH-J is halogen-free, but not fire-resistant. It is not suitable for fire alarm, smoke extraction or emergency lighting lines.

    FAQ

    What does N2XH-J mean?
    N – standardised cable, 2X – XLPE insulation, H – halogen-free sheath, J – with green-yellow PE conductor.
    What does RE mean?
    A round solid (single-wire) conductor.
    Can N2XH-J be used instead of NYY or CYKY?
    Yes, for fixed installation indoors; N2XH additionally offers halogen-free fire behaviour.
    Does this cable maintain its function during a fire?
    No. FE180/E90 cables, e.g. (N)HXH-J FE180/E90, are designed for that.
    Do you sell by the metre?
    Yes, we cut the required length from the drum.
    Can I pick it up in Šiauliai?
    Yes, you can pick up the cable at our office at J. Basanavičiaus g. 23, Šiauliai.

    N2XH-J 5×4 RE 0.6/1 kV – halogen-free cable

    Power cable with five solid copper conductors, XLPE insulation and a black halogen-free sheath, 0.6/1 kV, to DIN VDE 0276-604. Designed for three-phase lines in public buildings, escape routes and data centres.

    Published: 2026-11-17 · Data verified against the cable marking and DIN VDE 0276-604: 2026-11-17