Products catalog

  • Heat recovery unit with electric heater | for room ventilation | 40–250 m² | 300 m³/h | 1~230V

    Code: REGO-400VE

    Ventilation unit with a rotary heat exchanger for balanced ventilation of an apartment or house: 300 m³/h nominal airflow, up to 82 % heat recovery, EC fans 2 × 70 W, integrated 1 kW electric heater, Ø160 mm connections and kitchen hood connection.

  • Heat recovery unit with electric heater | for room ventilation | 40–250 m² | 300 m³/h | 1~230V

    Ventilation unit with a rotary heat exchanger (heat recovery unit) for balanced ventilation of an apartment or house: supplies filtered outdoor air, extracts indoor air and recovers part of the heat. Nominal airflow 300 m³/h, EC fans, integrated 1 kW electric heater, 1~230 V supply.

    Key idea:
    In an airtight home, vents and exhaust fans throw heat out with the air in winter. A heat recovery unit exchanges air continuously and in balance, and the rotary heat exchanger returns up to 82 % of the heat (temperature efficiency stated by the manufacturer) – rooms are ventilated without drafts and without large heating losses.
    Airflow
    300 m³/h (nominal)
    Heat recovery
    up to 82 %
    Fans
    EC, 2 × 70 W
    Heater
    1 kW, 1~230 V

    Operating principle

    Outdoor air is drawn in through a filter, passes the rotary heat exchanger and, if needed, is additionally heated by the electric heater, then supplied to living rooms through ducts. Extract air is taken from the bathroom, WC and kitchen, passes the filter and the heat exchanger and is discharged outdoors.

    The rotating wheel takes heat from the extract air and transfers it to the supply air. The unit has a kitchen hood connection – hood air is extracted without heat recovery so greasy vapours do not reach the heat exchanger.

    Ducts are connected via Ø160 mm spigots. Operating modes, airflow and supply air temperature are set on the C4.1 control panel.

    What does REGO-400VE give you?
    One unit covers ventilation of the whole apartment or house: filtered air is supplied continuously, moisture and odours are removed, and most of the heat stays indoors.

    Technical specifications

    Product type Ventilation unit with rotary heat exchanger (heat recovery unit), vertical duct connection
    Manufacturer / code Komfovent DOMEKT REGO 400VE | REGO-400VE
    Nominal airflow 300 m³/h
    Heat exchanger Rotary
    Temperature efficiency up to 82 %
    Recovered energy up to 3.5 kW
    Fans EC, 2 × 70 W
    Electric heater 1 kW, integrated
    Power supply ~230 V / 50 Hz, single phase
    Duct connections Ø160 mm
    Kitchen hood connection Yes – extraction without heat recovery
    Filters F5 / F7 class, panel type, 450 × 210 × 46 mm
    Control C4.1 automation control panel
    Weight 41 kg

    Main functions

    • Heat recovery – the rotary heat exchanger returns up to 82 % of heat, so pre-warmed rather than cold air is supplied in winter.
    • Continuous balanced ventilation – air is supplied and extracted – no drafts and no air drawn through window gaps.
    • Filtration – F5 / F7 class filters capture dust and pollen.
    • Electric heater – the 1 kW heater warms supply air to the set temperature.
    • Kitchen hood connection – kitchen hood air is extracted bypassing the heat exchanger.
    • Automation – modes, airflow and temperature are set on the control panel.

    Where is it used?

    • Apartments and houses with a duct system
    • Renovated and new energy-efficient buildings
    • Cottages and terraced houses
    • Small offices
    • Apartments where moisture builds up after window replacement
    • Homes where ventilation heat losses should be reduced

    Use by need

    For the homeowner.
    Clean air all the time without open windows and without large heating losses.
    For the ventilation installer.
    Compact 300 m³/h unit with Ø160 mm spigots, heater and kitchen hood connection.
    For the designer.
    Rotary heat exchanger with up to 82 % efficiency for balanced ventilation of an apartment or house.

    Practical use

    If windows fog up in winter and rooms cool down quickly when ventilated through a window, a heat recovery unit with ducts to the rooms (supply) and to the bathroom, WC and kitchen (extract) exchanges air continuously while most of the heat stays in the house. Airflows for each room are defined in the design.

    Pros

    • Rotary heat exchanger, up to 82 % efficiency
    • EC fans
    • Integrated 1 kW electric heater
    • Kitchen hood connection without heat recovery
    • F5 / F7 filters
    • Ø160 mm duct connections
    • Automation control panel

    Cons / limitations

    • Requires a duct system and design – not a single-room solution
    • Filters must be replaced regularly
    • Nominal airflow 300 m³/h – choose a more powerful unit for larger houses
    • Installation and commissioning must be done by qualified specialists

    Safety and installation notes

    • Make the electrical connection according to the manufacturer’s instructions, with proper protection and earthing; work is done by a qualified electrician.
    • Before servicing, disconnect the power and wait until the fans stop.
    • Leave access to the filters and heat exchanger for maintenance.
    • Connect the kitchen hood only via the dedicated connection – not to the common extract duct.
    • Install in a heated room; do not operate without filters.

    Quick selection guide

    300 m³/h
    Up to 82 %
    EC 2 × 70 W
    Heater 1 kW
    Ø160 mm
    Suitable when you need:
    • Whole-apartment or house ventilation with heat recovery
    • Ventilation without drafts and open windows
    • A unit with kitchen hood connection
    Check before use:
    • Space for the unit and ducts
    • Required airflow according to the design
    • 1~230 V supply with protection
    • Where filters will be serviced
    Important reminder: A heat recovery unit does not replace a ventilation design – airflows and the duct network are selected for each building individually.

    FAQ

    How much heat does this unit recover?
    According to the manufacturer, the rotary heat exchanger temperature efficiency is up to 82 %, recovered energy up to 3.5 kW.
    What is the nominal airflow?
    300 m³/h.
    What duct diameter is connected?
    Ø160 mm.
    Can a kitchen hood be connected?
    Yes, there is a kitchen hood connection – this air is extracted without heat recovery.
    Which filters are used?
    F5 / F7 class panel filters 450 × 210 × 46 mm.
    Is there a heater?
    Yes, an integrated 1 kW electric heater.

    Heat recovery unit with electric heater | for room ventilation | 40–250 m² | 300 m³/h | 1~230V

    REGO-400VE heat recovery unit – a ventilation unit with a rotary heat exchanger, 300 m³/h nominal airflow, up to 82 % heat recovery, EC fans and a 1 kW electric heater for balanced ventilation of an apartment or house.

    Published: 2026-11-04 · Data verified against the manufacturer datasheet: 2026-11-04

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Ducted wall-mounted mini heat recovery unit | D125 | up to 125 m³/h | up to 91 % heat recovery | 15–40 W | 220–240 V | 6 speeds | remote | IP24 | VENT-ELecuper 125
    Code: VENT-ELecuper 125

    Ducted wall-mounted mini heat recovery unit VENT-ELecuper 125: Ø125 mm, up to 125 m³/h, heat recovery up to 91 %, 15–40 W, 25–35 dB(A), 6 speeds, 4 modes, remote control, IP24.

    Price 219.07 € VAT incl.
    ( 181.05 € VAT excl. )
    Window trickle vent | adjustable | with G3 filter | 350 mm | white | no-drill installation | 350LVB
    Code: 37611

    350LVB – adjustable supply window trickle vent with G3 (EU3) filter: 350 mm long, 17.9 mm wide, white. Mounted on the sash of a PVC or wooden window without drilling the frame, fully closable with a slider.

    Price 25.41 € VAT incl.
    ( 21.00 € VAT excl. )
  • privacy policy

    Information