Products catalog

  • Heat recovery unit with speed controller | 3000 m³/h | 780 W | 230 V | Ø355 mm connections | 1540×1130×505 mm | galvanised steel | IP44 | ESLP21768

    Code: ESLP21768

    Heat recovery unit with speed controller ESLP21768: 3000 m³/h, 780 W, 230 V, Ø355 mm connections, 1540×1130×505 mm, galvanised steel housing, aluminium impeller, IP44, S1 continuous duty.

  • Heat recovery unit with speed controller | 3000 m³/h | 780 W | 230 V | Ø355 mm connections | 1540×1130×505 mm | galvanised steel | IP44 | ESLP21768

    Heat recovery unit with speed controller – a ventilation unit with heat recovery for a duct system with Ø355 mm connections. Air flow 3000 m³/h, power 780 W, supply 230 V, 50 Hz, galvanised sheet steel housing, IP44.

    Key point:
    The unit warms fresh air with heat from the exhaust air, so heating costs fall while ventilating. Duty type S1 means it is designed for continuous operation, and the speed controller matches capacity to actual demand.
    Air flow
    3000 m³/h
    Power
    780 W
    Connections
    Ø355 mm
    Protection
    IP44

    How it works

    The unit is connected to the supply and exhaust duct system via Ø355 mm spigots and powered from a 230 V, 50 Hz supply. Overall dimensions are 1540×1130×505 mm (L × W × H), so it can be installed in a plant room, loft or ceiling space if the structure allows.

    The aluminium impeller runs at 1465 rpm, air flow 3000 m³/h. Heat from the exhaust air is transferred to the supply air, and the speed controller sets the required capacity.

    The class F insulated motor and S1 duty are designed for continuous operation; operating temperature is −20 to +50 °C.

    Why choose ESLP21768?
    3000 m³/h ventilation with heat recovery and speed control for larger houses, commercial or technical premises.

    Technical specifications

    Product type Heat recovery unit with speed controller
    Product code ESLP21768
    Supply 230 V, 50 Hz
    Power 780 W
    Air flow 3000 m³/h
    Noise 49 dB(A)
    Rotational speed 1465 rpm
    Connection diameter Ø355 mm
    Dimensions (L × W × H) 1540×1130×505 mm
    Housing galvanised sheet steel, no additional coating
    Impeller aluminium
    Motor insulation class F
    Protection rating IP44
    Duty type S1 (continuous operation)
    Operating temperature −20 to +50 °C
    Standard EN 60204-1

    Main functions

    • Heat recovery – exhaust air heat warms the supply air, cutting heating costs.
    • Speed control – capacity is matched to demand.
    • S1 duty – designed for continuous operation.
    • Galvanised steel housing – robust construction for plant rooms.
    • Class F motor insulation – thermal margin in continuous operation.
    • IP44 – protection against solids over 1 mm and water splashes.

    How the models in this series differ

    • 1000 m³/h · ESLP21767 – 250 W · 50 dB(A) · Ø250 mm · 967×760×320 mm
    • 2000 m³/h · ESLP21769 – 400 W · 48 dB(A) · Ø305 mm · 1150×980×405 mm
    • 3000 m³/h · ESLP21768 – 780 W · 49 dB(A) · Ø355 mm · 1540×1130×505 mm – this model

    Where is it used?

    • Large detached houses
    • Offices and administrative premises
    • Shops and halls
    • Workshops and garages
    • Basements and plant rooms
    • HVAC systems of commercial buildings

    Use by need

    For the design engineer.
    Clear key data – 3000 m³/h, 780 W, Ø355 mm connections and dimensions – for preliminary selection.
    For the electrician.
    Single-phase 230 V supply and class F motor insulation.
    For the commercial property owner.
    Continuous ventilation with heat recovery reduces heating costs.

    Practical use

    If a building needs about 3000 m³/h of ventilation and has a plant room where a 1540×1130×505 mm unit fits, ESLP21768 is connected to Ø355 mm ducts and the speed controller reduces capacity when fewer people are present. Before ordering, check the system resistance and heat recovery data.

    Pros

    • Heat recovery reduces heating costs
    • Speed control
    • S1 – continuous operation
    • Galvanised steel housing
    • IP44
    • Operates from −20 to +50 °C

    Cons / limitations

    • Housing has no internal acoustic lining
    • Large dimensions – not for small rooms
    • The supplier does not state heat recovery efficiency, heat exchanger type or filter class
    • Operating temperature from −20 °C – colder climates need extra measures

    Safety and installation notes

    • Disconnect the supply and verify absence of voltage before installation and maintenance.
    • Protect the supply circuit with a circuit breaker sized for the 780 W load.
    • Fix the unit to a structure able to carry its weight and leave service access.
    • Connect ducts airtight; inlet and outlet openings must not be blocked.
    • Install in an ambient of −20 to +50 °C.
    • Connection must be carried out by a qualified electrician.

    Quick selection guide

    3000 m³/h
    780 W
    230 V
    Ø355 mm
    IP44
    S1
    Suitable when you need:
    • To ventilate a building needing about 3000 m³/h
    • To reduce heating costs while ventilating
    • Continuously operating ventilation systems
    Check before use:
    • Whether a 1540×1130×505 mm unit fits in the plant room
    • Whether the ducts are Ø355 mm
    • Whether capacity is sufficient after system resistance
    • What heat recovery efficiency the project requires
    Important reminder: The unit does not replace a ventilation design: air volumes, ducts and noise attenuation must be selected by a designer.

    FAQ

    What is the air flow?
    3000 m³/h.
    What is the connection diameter?
    Ø355 mm.
    Is it suitable for continuous operation?
    Yes, duty type S1.
    What is the protection rating?
    IP44.
    Does the housing have acoustic insulation?
    No, the housing has no internal acoustic lining.
    What is the heat recovery efficiency?
    The supplier does not state it – contact us for data before ordering.

    Heat recovery unit with speed controller | 3000 m³/h | 780 W | 230 V | Ø355 mm connections | 1540×1130×505 mm | galvanised steel | IP44 | ESLP21768

    ESLP21768 is a heat recovery unit with speed controller: 3000 m³/h, 780 W, 230 V, Ø355 mm connections, 1540×1130×505 mm, galvanised steel, IP44, S1. For ventilation with heat recovery in houses, commercial and technical premises.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Ducted wall-mounted mini heat recovery unit | D125 | up to 125 m³/h | up to 91 % heat recovery | 15–40 W | 220–240 V | 6 speeds | remote | IP24 | VENT-ELecuper 125
    Code: VENT-ELecuper 125

    Ducted wall-mounted mini heat recovery unit VENT-ELecuper 125: Ø125 mm, up to 125 m³/h, heat recovery up to 91 %, 15–40 W, 25–35 dB(A), 6 speeds, 4 modes, remote control, IP24.

    Price 219.07 € VAT incl.
    ( 181.05 € VAT excl. )
    Window trickle vent | adjustable | with G3 filter | 350 mm | white | no-drill installation | 350LVB
    Code: 37611

    350LVB – adjustable supply window trickle vent with G3 (EU3) filter: 350 mm long, 17.9 mm wide, white. Mounted on the sash of a PVC or wooden window without drilling the frame, fully closable with a slider.

    Price 25.41 € VAT incl.
    ( 21.00 € VAT excl. )