Products catalog

  • High-voltage transformer insulation tester | capacitance and insulation loss meter | 0.5–10 kV | 230 V | IP67

    Code: ES-VLUUKE10

    High-voltage transformer insulation tester designed for measuring Cx capacitance, tgδ / Tan Delta, dissipation factor, and for assessing the overall condition of insulation.

    This tester is used where it is necessary to evaluate the quality of electrical equipment insulation, ageing, moisture impact, defects, or possible failure risk. Thanks to its 0.5–10 kV high-voltage output, automatic frequency switching, and high-accuracy measurement functions, the device is suitable for both preventive equipment diagnostics and technical maintenance in energy, industrial, and electrical network facilities. 

  • Technical specifications

    Product type: transformer capacitance and Tan Delta meter
    Purpose: testing of insulation, capacitance and dielectric losses of electrical equipment
    Measurement functions: Cx capacitance, tgδ / Tan Delta, dissipation factor
    High-voltage output: 0.5–10 kV
    Voltage adjustment: in 500 V steps
    Number of voltage levels: 20 levels
    Output power: 1500 VA
    Accuracy class: 0.2
    tgδ accuracy: ±(reading × 1.5% + 0.06%)
    Cx accuracy: ±(reading × 1.5% + 5 pF)
    tgδ resolution: 0.01%
    Cx resolution: 1 pF
    Measurement range: from 0.01%
    Minimum capacitance measurement: from 3 pF
    Capacitance measurement limit at 10 kV: Cx ≤ 30000 pF
    Capacitance measurement limit at 5 kV: Cx ≤ 60000 pF
    Power supply: AC 230 V ±10%
    Frequency: 50 ±1 Hz
    Operating measurement frequency: 50 Hz
    Variable frequency mode: 45 Hz / 55 Hz
    Frequency switching: automatic
    Harmonic adaptation: ≤3%
    Protection class: IP67
    Housing material: aluminium alloy
    Operating temperature: from -15 °C to +50 °C
    Relative humidity: <80%
    Dimensions: 460 x 345 x 350 mm
    Weight: 35 kg

    Functions

    Transformer insulation testing – helps assess whether the insulation is aged, damp or damaged
    Cx capacitance measurement – measures the capacitance of electrical equipment and helps evaluate its technical condition
    Tan Delta / tgδ measurement – indicates insulation losses and helps identify possible insulation defects
    High-voltage testing up to 10 kV – designed for professional inspection of transformers, cables and other high-voltage equipment
    Adjustable test voltage 0.5–10 kV – allows the appropriate voltage level to be selected according to the equipment being tested
    Automatic 45 Hz / 55 Hz frequency switching – reduces the influence of mains interference and helps obtain more accurate measurement results
    High-accuracy measurements – ensures reliable results during diagnostics and preventive maintenance
    Robust IP67 housing – protects the device from dust and moisture in the working environment

    Usage

    For power grid and energy companies: Suitable for electrical substations, distribution networks, high-voltage equipment maintenance and periodic diagnostics. It can be used to test the insulation condition of transformers, cables, insulators, capacitors and other equipment.

    For engineers: Useful for insulation quality assessment, fault analysis, preventive testing and preparation of technical condition reports. Cx and tgδ measurements allow informed decisions to be made regarding equipment operation, repair or replacement.

    For electricians: Useful for checking high-voltage equipment after installation, repair or preventive maintenance work. The device helps determine whether the insulation is in suitable condition before the equipment is put into operation.

    For industrial companies: Can be used for diagnostics of production transformers, motors, cable lines, compensation equipment and other electrical systems. Regular measurements help reduce the risk of unplanned failures and downtime.

    For laboratories and testing centres: Suitable as a professional measuring tool for testing electrical insulation parameters. The high-voltage output, accurate capacitance measurement and Tan Delta function allow specialised technical tests to be performed.

    Advantages

    Measures Cx capacitance and dielectric losses tgδ / Tan Delta
    Suitable for diagnostics of transformers, cables, insulators and capacitors
    High-voltage output from 0.5 kV to 10 kV
    Voltage adjustable in 500 V steps
    High output power – 1500 VA
    High measurement accuracy
    Automatic 45 Hz / 55 Hz frequency switching

    Disadvantages

    The device weighs about 35 kg, so it is not a lightweight portable tester
    Designed for professional use, not for household tasks

    FAQ

    Who is this tester designed for?
    This device is designed to evaluate the insulation condition of transformers, cables, capacitors, insulators and other electrical equipment. It measures Cx capacitance and the dielectric loss factor tgδ / Tan Delta.

    What does Tan Delta measurement show?
    Tan Delta measurement shows insulation losses. The higher the tgδ value, the greater the likelihood that the insulation is damaged, damp, aged or contaminated.

    Is this device suitable for transformer diagnostics?
    Yes, the device is designed for testing the electrical parameters and insulation condition of transformers. It can be used for preventive maintenance, fault diagnostics and periodic testing.

    What is the maximum test voltage?
    The maximum high-voltage output value is 10 kV. The voltage is adjustable from 0.5 kV to 10 kV in 500 V steps. 

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.