Products catalog

Contactors | Electrical starters | For equipment control

  • Contactors are electromechanical switching devices operating on an electromagnetic principle, designed for automatic or remote switching of motors, pumps, fans, heating systems, lighting and other electrical loads.

    They are not intended for precise power regulation, motor speed control, overload protection or short-circuit protection – these functions require additional control and protective devices.

    KibirkštisFazė
    Which contactor does your motor need? A 30-second table from 2.2 to 45 kW with contactor and thermal overload relay is in the contactor and relay guide.
    Read more
  • ● Contactor – explained simply

    A contactor is an electrically controlled switching device that allows a low-power control circuit to switch a considerably higher-power electrical load on or off.

    Contactors are commonly used to control electric motors, pumps, fans, compressors, heating equipment, lighting groups and automation systems.

    ● How does a contactor work?

    A control voltage is applied to the contactor coil terminals A1–A2. The coil creates a magnetic field which mechanically operates the main and auxiliary contacts.

    This allows a push button, relay, PLC or another automation device to control an electrical load of considerably higher power.

    ● Contactor schematic designations

    These designations are used in electrical schematics and help identify the function of contactor terminals regardless of the language used in the documentation.

    KM contactor designation in an electrical schematic
    A1 – A2 electromagnetic coil terminals
    1L1 – 2T1 first main power contact
    3L2 – 4T2 second main power contact
    5L3 – 6T3 third main power contact
    13 – 14 NO – normally open auxiliary contact
    21 – 22 NC – normally closed auxiliary contact

    ● What do NO and NC mean?

    NO (Normally Open) – in the normal de-energised state, the contact is open. When the contactor operates, it closes.

    NC (Normally Closed) – in the normal de-energised state, the contact is closed. When the contactor operates, it opens.

    ● How to choose a contactor?

    A contactor should not be selected only by the highest current value shown on its housing.

    • Load type – motor, heater, lighting or another load.
    • Motor power – check the manufacturer's specified kW rating at the relevant supply voltage.
    • AC-3 current – one of the most important parameters when controlling asynchronous electric motors.
    • AC-1 current – mainly applies to resistive or slightly inductive loads.
    • Coil voltage – must correspond to the control circuit voltage.
    • Auxiliary contacts – NO and NC contacts are used for self-holding, interlocking, signalling and automation.
    • Number of poles – 3-pole contactors are commonly used for three-phase motors.

    ● Warning – coil voltage is not the main power circuit voltage

    If the contactor coil is marked 24 V AC, 42 V AC, 110 V AC or 230 V AC, this value refers to the A1–A2 control coil voltage. It must not be confused with the main power circuit voltage. Applying an incorrect voltage to the coil may damage the contactor.

    ● What do AC-1 and AC-3 mean?

    AC-1 – utilisation category for resistive or slightly inductive loads, for example electrical heating.

    AC-3 – one of the most important utilisation categories when controlling three-phase asynchronous motors. Therefore, a motor contactor should not be selected solely by its higher AC-1 rating – always check the AC-3 current and motor power.

    ● Where are contactors used?

    Electric motors Pumps Fans Compressors Heating equipment Lighting Conveyors Automation panels Refrigeration equipment Lifting equipment

    A contactor is generally used when an electrical load must be switched frequently, automatically or remotely.

    ● Key difference: contactor or relay?

    Contactor – mainly for power circuits.
    Relay – mainly for control and signalling circuits.

    A contactor is generally designed for larger loads and frequent switching. Relays are more commonly used in signalling, control and automation circuits and for smaller loads. This is a useful rule of thumb – the actual capabilities of a device must always be checked against the manufacturer's technical data.

    ● Common selection mistake

    A higher rated contactor current does not automatically mean that it is suitable for a particular motor. Motor starting current can be considerably higher than normal operating current, therefore the AC-3 category, motor power, supply voltage and manufacturer's recommendations must be considered.

    ● Quick terminology guide

    Coil electromagnetic part of the contactor supplied with the control voltage
    Main contacts contacts through which the main load current flows
    Auxiliary contacts contacts used for control, signalling, self-holding and interlocking
    AC-3 utilisation category particularly important for switching asynchronous electric motors
    NO normally open contact
    NC normally closed contact

    ● LOTO – Lockout / Tagout

    LOTO is a safety procedure for isolating, locking and identifying energy sources in order to prevent accidental or unauthorised energisation of equipment while work is being carried out.

    Where applicable, the energy source must be physically isolated, locked and clearly tagged. Re-energisation must only take place in accordance with the established safety procedure and by authorised personnel.

    ● DANGER – INCORRECT ELECTRICAL WORK CAN CAUSE SERIOUS INJURY OR DEATH

    Selection, connection, installation, replacement, adjustment and commissioning of electrical equipment must only be carried out by a specialist who has the qualifications, competence and authorisation required for the specific work.

    Contact with live parts, working on an improperly isolated circuit or incorrect connection of equipment is dangerous. Such errors may cause fatal electric shock, arc flash, severe burns, fire, explosion or equipment damage.

    Before starting work:

    • isolate all relevant energy sources;
    • protect the equipment against accidental re-energisation;
    • where applicable, use the LOTO lockout/tagout procedure;
    • verify absence of voltage using suitable test equipment;
    • use personal protective equipment appropriate for the work;
    • follow the manufacturer's documentation and applicable electrical safety and occupational safety requirements.

    If there is any doubt whether the work can be carried out safely, do not start the work and consult a qualified electrical professional.

    Read more
    Auxiliary contact block for LC1K contactors | 2NO + 2NC | top-mounted on the contactor
    Code: LA1KN22
    Auxiliary contact block designed for LC1K series contactors. The block is mounted on top of the contactor and provides 2 normally open (2NO) and 2 normally closed (2NC) auxiliary contacts. It is used to expand the contactor’s control, signalling, interlocking and automation circuits. 
    Price 8.22 € VAT incl.
    ( 6.79 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 400 A (AC-3) | 220 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC70400110
    Code: FC70400110

    FC70400110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 376.00 € VAT incl.
    ( 310.74 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 315 A (AC-3) | 160 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC70315110
    Code: FC70315110

    FC70315110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 371.22 € VAT incl.
    ( 306.79 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 250 A (AC-3) | 132 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC60250110
    Code: FC60250110

    FC60250110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 157.83 € VAT incl.
    ( 130.44 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 200 A (AC-3) | 90 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC60200110
    Code: FC60200110

    FC60200110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 144.91 € VAT incl.
    ( 119.76 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 160 A (AC-3) | 75 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC60160110
    Code: FC60160110

    FC60160110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 136.50 € VAT incl.
    ( 112.81 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 125 A (AC-3) | 55 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC50125110
    Code: FC50125110

    FC50125110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 111.45 € VAT incl.
    ( 92.11 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 100 A (AC-3) | 45 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC50100110
    Code: FC50100110

    FC50100110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 106.54 € VAT incl.
    ( 88.05 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 80 A (AC-3) | 37 kW/400 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC50080110
    Code: FC50080110

    FC50080110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 93.62 € VAT incl.
    ( 77.37 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 63 A (AC-3) | 18.5 kW/230 V | 4 NO + 2 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC50063110
    Code: FC50063110

    FC50063110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 84.71 € VAT incl.
    ( 70.01 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 75 A (AC-3) | 37 kW/400 V | 1 NO + 1 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40075110
    Code: FC40075110

    FC40075110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 61.58 € VAT incl.
    ( 50.89 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 75 A (AC-3) | 37 kW/400 V | 1 NO + 1 NC | Coil 42 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40075042
    Code: FC40075042

    FC40075042 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 42 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 61.58 € VAT incl.
    ( 50.89 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 75 A (AC-3) | 37 kW/400 V | 1 NO + 1 NC | Coil 36 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40075036
    Code: FC40075036

    FC40075036 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 36 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 61.58 € VAT incl.
    ( 50.89 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 63 A (AC-3) | 30 kW/400 V | 1 NO + 1 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40063110
    Code: FC40063110

    FC40063110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 57.52 € VAT incl.
    ( 47.54 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 63 A (AC-3) | 30 kW/400 V | 1 NO + 1 NC | Coil 42 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40063042
    Code: FC40063042

    FC40063042 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 42 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 57.52 € VAT incl.
    ( 47.54 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 63 A (AC-3) | 30 kW/400 V | 1 NO + 1 NC | Coil 36 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40063036
    Code: FC40063036

    FC40063036 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 36 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 57.52 € VAT incl.
    ( 47.54 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 50 A (AC-3) | 22 kW/400 V | 1 NO + 1 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40050110
    Code: FC40050110

    FC40050110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 42.02 € VAT incl.
    ( 34.73 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 50 A (AC-3) | 22 kW/400 V | 1 NO + 1 NC | Coil 42 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40050042
    Code: FC40050042

    FC40050042 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 42 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 42.02 € VAT incl.
    ( 34.73 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 50 A (AC-3) | 22 kW/400 V | 1 NO + 1 NC | Coil 36 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40050036
    Code: FC40050036

    FC40050036 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 36 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 42.02 € VAT incl.
    ( 34.73 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 40 A (AC-3) | 18,5 kW/400 V | 1 NO + 1 NC | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40040110
    Code: FC40040110

    FC40040110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 36.12 € VAT incl.
    ( 29.85 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 40 A (AC-3) | 18,5 kW/400 V | 1 NO + 1 NC | Coil 42 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40040042
    Code: FC40040042

    FC40040042 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 42 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 36.12 € VAT incl.
    ( 29.85 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 40 A (AC-3) | 18,5 kW/400 V | 1 NO + 1 NC | Coil 36 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC40040036
    Code: FC40040036

    FC40040036 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 36 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 36.12 € VAT incl.
    ( 29.85 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 32 A (AC-3) | 15 kW/400 V | 1 NO | Coil 110 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC30032110
    Code: FC30032110

    FC30032110 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil is rated for a 110 V AC control circuit, usually supplied from a separate control transformer. Note: 110 V is not a safety extra-low voltage (SELV ≤ 50 V AC) – the control circuit requires the same protection measures as mains voltage.

    Price 22.86 € VAT incl.
    ( 18.89 € VAT excl. )
    Industrial Magnetic Contactor | 3P | 32 A (AC-3) | 15 kW/400 V | 1 NO | Coil 42 V AC | IEC/EN 60947-4-1 | Promfactor Baltic FC30032042
    Code: FC30032042

    FC30032042 is a three-phase electromagnetic contactor designed for switching electrical circuits on and off in industrial, administrative and commercial premises as well as civil construction sites. It is used to control motors, heating systems and other loads where frequent, reliable circuit switching is needed without manual intervention. This version's control coil operates on 42 V AC – a low safety voltage – so the contactor is suitable for environments where a 230 V control circuit is undesirable or prohibited.

    Price 22.86 € VAT incl.
    ( 18.89 € VAT excl. )