Products catalog

  • Industrial switch-disconnector | 3P | 200A | FMD3 frame | ~690 V | IP20 | manual operation | Promfactor Baltic | FMD30200

    Code: FMD30200
    Barcode: 4772151002450

    FMD30200 – Promfactor Baltic industrial switch-disconnector 3P 200 A, ~690 V, IP20, in the FMD3 frame with FMC3 accessories, for safe isolation of panels and lines.

  • Industrial switch-disconnector | 3P | 200A | FMD3 frame | ~690 V | IP20 | manual operation | Promfactor Baltic | FMD30200

    FMD30200 – a Promfactor Baltic industrial three-pole switch-disconnector in the FMD3 frame with a rated current of 200 A. It is designed for manually switching on, switching off and isolating a three-phase circuit in distribution and incoming panels. The switch-disconnector has no thermal or electromagnetic release – it does not protect against overload and short circuit, so the circuit must be protected by a circuit breaker or fuses installed upstream. Insulation voltage Ui 800 V, rated voltage Un ~690 V, impulse voltage Uimp 8000 V, 50/60 Hz; degree of protection IP20, weight 1.80 kg. Compatible Promfactor FMC3/3U (FMD) accessories: auxiliary contact F/AX3R (right-hand) or F/AX3L (left-hand), 1NO+1NC; alarm contact F/AL3L (left-hand); shunt trip F/SH3230R, 230 V, right-hand; remote control unit MROM33, 230 V.

    Key idea:
    A switch-disconnector is a clear and reliable isolation point: a single handle isolates all three phases up to 200 A at once, so the panel, line or equipment is disconnected from the supply before repair or maintenance. Since FMD3 uses the same accessories as FMC3 circuit breakers, the switch-disconnector and the circuit breaker in the panel are equipped following the same logic.
    Rated current
    200 A
    Number of poles
    3P
    Voltage
    Un ~690 V, Ui 800 V, Uimp 8000 V
    Housing / protection
    FMD3, IP20, 1.80 kg

    Operating principle

    The FMD30200 switch-disconnector is mounted in the panel on a mounting plate; supply cables or busbars are connected to the three input terminals and the load to the three output terminals. A protective device must be installed upstream of the switch-disconnector – a circuit breaker (e.g. FMC33U0200 of the same current) or fuses selected according to the cable and load parameters.

    When the handle is turned or switched, the contacts simultaneously connect or disconnect all three phases up to a rated current of 200 A. The position status can be transmitted to a controller or control room via the F/AX3R auxiliary contact, and with the MROM33 remote control unit the switch-disconnector can be switched on and off by a remote 230 V signal; with the F/SH3230R shunt trip release it can be switched off by a remote 230 V signal. The switch-disconnector is designed for ~690 V (50/60 Hz) networks, insulation voltage Ui 800 V, impulse withstand voltage Uimp 8000 V; FMD3 frame endurance – 2,500 electrical and 8,500 mechanical on/off cycles.

    Result – a clear isolation point for a three-phase circuit up to 200 A, enabling safe repair or maintenance and the use of common FMC3/FMD3 accessories in the control panel.

    Benefits FMD30200?
    200 A three-pole switch-disconnector in the FMD3 frame with shared FMC3/3U (FMD) accessories – uniform panel equipment for circuit breakers and switch-disconnectors, with the option to signal position and trip the circuit remotely.

    Technical specifications

    Product type Industrial switch-disconnector (load switch-isolator)
    Manufacturer / code Promfactor Baltic / FMD30200
    Series / frame FMD3 (FMD30100 … FMD30250)
    Number of poles 3P
    Rated current 200 A
    Barcode (EAN) 4772151002450
    Standard (according to the e-shop product page) IEC/EN 60947-2
    Operating frequency 50/60 Hz
    Insulation voltage (Ui) 800 V
    Rated voltage (Un) ~690 V
    Impulse voltage (Uimp) 8000 V
    Electrical strength 2 500 switching (on/off) cycles
    Mechanical endurance 8 500 switching (on/off) cycles
    Degree of protection IP20
    Ambient operating temperature -25…+55 °C
    Storage temperature -25…+70 °C
    Weight 1.80 kg
    Control manual, handle on the housing
    Overload / short-circuit protection none (a protective device upstream of the switch-disconnector is required)
    Auxiliary contact F/AX3R (right-hand) or F/AX3L (left-hand), 1NO+1NC
    Signal contact F/AL3L (left-hand)
    Shunt trip release F/SH3230R, 230 V, right-hand
    Remote control unit MROM33, 230 V
    Circuit breaker of the same current rating FMC33U0200 (FMC3/3U, 50 kA)

    Main functions

    • Three-pole isolation – a single handle simultaneously connects or disconnects all three phases up to 200 A.
    • Manual control – status and isolation are handled by the installer directly in the control panel, without additional control circuits.
    • For networks up to ~690 V – Ui 800 V and Uimp 8000 V – suitable for 400 V and 690 V industrial networks.
    • Isolation for repair – the line or control panel section is isolated from the supply before maintenance or equipment replacement.
    • Position signalling – auxiliary contact F/AX3R (right-hand) or F/AX3L (left-hand), 1NO+1NC transmits the status to a controller or control room.
    • Signal contact – F/AL3L signals that the switch-disconnector has been tripped by the shunt release.
    • Remote tripping – the F/SH3230R shunt trip release switches off the switch-disconnector with a 230 V signal – suitable for emergency disconnection.
    • Remote control – the MROM33 remote control unit allows the switch-disconnector to be switched on and off by a 230 V signal.
    • Shared accessories with FMC3 – the same FMC3/3U (FMD) accessories also fit the FMC33U0200 circuit breaker – smaller stock.

    Where is it used?

    • Building incoming and distribution control panels
    • Power panels in apartment buildings
    • Pumping stations and boiler rooms
    • Production workshop line panels
    • Agricultural sites – livestock farms, dryers
    • Group control panels in retail and office buildings
    • Isolating motors and process equipment groups for repair

    On-demand operation

    For electricians of pumping stations and wastewater treatment plants.
    The 200 A switch-disconnector suits the incomer of a pumping station power panel when all phases must be clearly isolated before servicing.
    For control panel manufacturers using FMC33U0200.
    an FMD3 switch-disconnector and an FMC3 circuit breaker of the same current share common accessories F/AX3, F/AL3L, F/SH3230R and MROM33.
    For shopping centre technical services.
    Isolating a 200 A group allows a distribution board to be repaired without cutting power to the whole building.

    Practical application

    If the panel needs a separate three-phase isolation point for a line whose operating current does not exceed 200 A, then FMD30200 is installed downstream of the protective circuit breaker (e.g. FMC33U0200), all three phases are isolated with a single handle before repairs, and its position is transmitted to the controller via F/AX3R.

    Application guide: how it is used in practice

    FMD30200 adapts to different sites – only what is connected and which accessories are used changes:

    Site What is connected Result Installer's note
    Incoming control panel Incoming cable via a protective circuit breaker → FMD30200 → distribution busbars The whole control panel is isolated with a single handle The switch-disconnector does not protect – select the protective device according to the cable
    Line or equipment group Circuit supply up to 200 A via FMD30200 The circuit is isolated for repair without affecting other circuits Mark the isolated position and attach a warning sign
    Remotely monitored site F/AX3R contacts → PLC / BMS input Switch-disconnector position visible remotely Match the contact side (left / right) to the control panel layout
    Emergency disconnection Emergency button → F/SH3230R (230 V) The switch-disconnector is tripped by a remote signal Take the shunt trip supply from a reliable 230 V source
    Remote control MROM33 + control signal 230 V The switch-disconnector is switched on and off remotely Order the control unit separately

    How to select the current and frame of an FMD switch-disconnector

    Rated current / frame Recommended model
    100 A, FMD3 frame FMD30100 (smaller incomers, building panels)
    125 A, FMD3 frame FMD30125 (distribution boards, small incomers)
    160 A, FMD3 frame FMD30160 (building and workshop incomers)
    200 A, FMD3 frame FMD30200 (power panels, pumping stations) ← this model
    225 A, FMD3 frame FMD30225 (intermediate size between 200 and 250 A)
    250 A, FMD3 frame FMD30250 (highest current of the FMD3 frame)
    250 A, FMD4 frame FMD40250 (250 A in the FMD4 frame with FMC4 accessories)
    315 A, FMD4 frame FMD40315 (0.4 kV substation lines, workshop incomers)
    400 A, FMD4 frame FMD40400 (highest current of the FMD4 frame)
    400 A, FMD5 frame FMD50400 (400 A in the FMD5 frame with FMC5 accessories)
    500 A, FMD5 frame FMD50500 (main distribution boards)
    630 A, FMD5 frame FMD50630 (highest current of the FMD5 frame)
    800 A, FMD6 frame FMD60800 (main incomers, transformer substations)
    Rule: the rated current of the switch-disconnector must be no lower than the rating of the upstream protective device and the operating current of the circuit. Where the same current is available in two frames (250 A – FMD3 or FMD4; 400 A – FMD4 or FMD5), the smaller frame saves space, while the larger one allows the current to be increased later within the same frame and the use of larger-frame accessories. The switch-disconnector does not provide protection – protection is always provided by a circuit breaker or fuses.
    When to choose another solution: other currents in the same FMD3 frame – FMD30100, FMD30125, FMD30160, FMD30225, FMD30250; for protection at the same current – circuit breaker FMC33U0200; for modular circuits up to 125 A – FSD3 series modular switch-disconnectors (e.g. FSD34125); accessories – auxiliary contact F/AX3R (right-hand) or F/AX3L (left-hand), 1NO+1NC; signal contact F/AL3L (left-hand); shunt trip release F/SH3230R, 230 V, right-hand; remote control unit MROM33, 230 V.

    Pros

    • Three-pole isolation up to 200 A with a single handle
    • Shared FMC3/3U (FMD) accessories with FMC3 circuit breakers
    • Position contact F/AX3R (right-hand) or F/AX3L (left-hand), 1NO+1NC
    • Remote tripping with the F/SH3230R release
    • Clear isolation point for repair and maintenance
    • Un ~690 V, Ui 800 V, Uimp 8000 V; 2,500 electrical / 8,500 mechanical cycles
    • Remote control with MROM33

    Cons / limitations

    • Does not protect against overload and short circuit – a circuit breaker or fuses are required upstream of the switch-disconnector
    • Auxiliary contacts, releases and control units are ordered separately
    • IP20 – install only in a closed panel or cabinet; operating temperature -25…+55 °C
    • Three-pole version only – the N conductor is not isolated by the switch-disconnector

    Safety and installation notes

    • Installation and connection must be carried out by a qualified electrician after disconnecting the supply and verifying the absence of voltage.
    • A switch-disconnector is not a protective device – the circuit must be protected by a circuit breaker or fuses selected according to the cable and load.
    • Tighten the terminal screws to the torque specified by the manufacturer and use cables or busbars with a cross-section matching the current.
    • Before starting work, lock the isolated switch-disconnector or mark it with a warning sign and verify the absence of voltage on the output side.
    • Install accessories (contacts, releases, control units) only after the switch-disconnector and its circuits have been de-energised.

    Quick selection guide

    3P
    200 A
    ~690 V
    IP20
    FMD3
    Manual control
    FMC3 accessories
    Remote control
    Suitable when you need:
    • isolate a three-phase circuit or control panel with an operating current of up to 200 A;
    • create a clear isolation point for repair and maintenance;
    • configure the control panel with FMC3 circuit breakers and common accessories.
    Check before use:
    • whether the operating current of the circuit and the rating of the protective device upstream of the switch-disconnector do not exceed 200 A;
    • whether the circuit is protected by a circuit breaker or fuses;
    • which accessories are required: position contact, release, remote control unit.
    Important reminder: FMD30200 is a switch-disconnector, not a circuit breaker – it does not protect against overload and short circuit, and accessories are ordered separately.

    FAQ

    Does FMD30200 protect against short circuits?
    No, FMD30200 has no protective releases, so a circuit breaker or fuses must be installed upstream of it.
    What is the rated current of FMD30200?
    The rated current of FMD30200 is 200 A, the rated voltage is ~690 V, and the switch-disconnector isolates three poles.
    Which auxiliary contacts are suitable?
    F/AX3R (right-hand) or F/AX3L (left-hand), 1NO+1NC and signal contact F/AL3L (left-hand) are suitable.
    Can the switch-disconnector be switched off remotely?
    Yes, with the F/SH3230R shunt trip release, 230 V, right-hand, and for switching on and off – with the MROM33 remote control unit, 230 V.
    How does FMD differ from FMC?
    FMC3 is a circuit breaker with overcurrent protection, while FMD3 is a switch-disconnector of the same frame series without protection, using shared accessories.
    How many operations can the switch-disconnector withstand?
    The FMD3 frame switch-disconnector withstands 2 500 electrical and 8 500 mechanical switching (on/off) cycles.

    Industrial switch-disconnector | 3P | 200A | FMD3 frame | ~690 V | IP20 | manual operation | Promfactor Baltic | FMD30200

    Promfactor Baltic FMD30200 – industrial three-pole switch-disconnector 200 A in an FMD3 frame with manual operation, compatible with FMC3/3U (FMD) accessories: auxiliary contacts, shunt trip release and remote control unit – for isolating incoming and distribution control panels, lines and equipment groups.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information