Products catalog

  • Interface relay | 2CO | 8 A | coil 24 V DC | plug-in | Schneider Electric RSB2A080BD

    Code: RSB 2A080BD
    Barcode: 13389110252368

    Schneider Electric RSB2A080BD – interface relay with 2CO contacts (8 A) and 24 V DC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.

  • Interface relay | 2CO | 8 A | coil 24 V DC | plug-in | Schneider Electric RSB2A080BD

    Schneider Electric RSB2A080BD is an interface relay with a 24 V DC coil and 2CO changeover contacts rated 8 A. It receives a weak control signal and switches another circuit through a galvanically isolated contact.

    Key point:
    24 V DC outputs of PLCs and controllers usually cannot drive a contactor coil, a valve or a 230 V circuit directly. A relay with a 24 V DC coil does it safely: the output only carries the coil current, while a separate contact switches the load.
    Contacts
    2CO
    Rated current
    8 A / 250 V AC
    Coil voltage
    24 V DC (0.45 W)
    Insulation coil–contacts
    5000 V AC

    Operating principle

    The relay plugs into a suitable socket on a DIN rail (or is soldered to a PCB). The control voltage is applied to coil terminals A1–A2.

    When current flows through the coil, the electromagnet pulls the armature and switches the contacts: the common contact (COM) leaves NC and closes to NO. When the control voltage drops, a spring returns the contacts to their initial position.

    Coil and contact circuits are galvanically isolated, so a weak control signal safely controls a circuit at another voltage.

    Why choose Schneider Electric RSB2A080BD?
    Schneider Electric Harmony (Zelio) RSB2A080BD – a 2CO 8 A relay with a low-power coil (0.45 W) and 5000 V AC coil–contact insulation. Mounts in the RSZE1S48M socket with separate coil and contact terminals.

    Technical specifications

    Product type Interface (control) relay
    Manufacturer / code Schneider Electric RSB2A080BD
    Series Harmony (Zelio) RSB
    Coil voltage 24 V DC
    Coil power 0.45 W; ~1440 Ω
    Operate / release voltage 16.8…36 V DC; drop-out ≥0.1 Uc
    Contacts 2CO
    Contact material AgNi
    Rated current 8 A NO / 4 A NC (AC-1/DC-1)
    Max. switching voltage 250 V AC; 28 V DC (8 A)
    Rated load AC1 2000 VA / 224 W
    Mechanical life 30 × 10⁶ cycles
    Electrical life 100 × 10³ cycles (8 A, 250 V, AC-1)
    Insulation coil–contacts 5000 V AC; 3.6 kV
    Operate / release time 20 ms / 20 ms
    Operating temperature −40…+85 °C
    Weight 14 g
    Mounting plug-in, socket-mounted
    Indication none (LED via socket module)
    Protection class IP40; RT I
    Standards / approvals IEC 61810-1, UL 508, CSA C22.2 No.14; CE, EAC
    Compatible sockets Schneider Electric RSZE1S48M

    Main functions

    • Galvanic isolation – the control circuit is protected from load circuit disturbances.
    • 2CO contacts – one signal can control a load and return a status signal.
    • Signal amplification – a weak PLC or controller output switches a 8 A load.
    • Plug-in mounting – fast replacement without disconnecting wires.
    • Voltage conversion – control at one voltage, load at another (e.g. 24 V → 230 V).

    Where is it used?

    • Isolation and amplification of PLC outputs
    • Control of contactor and motor starter coils
    • Solenoid valve control
    • Signal transfer between systems with different voltages
    • Control panels of industrial machinery
    • Pumping stations, boiler rooms, ventilation units
    • Control of signal lamps and sirens

    Use by need

    Automation integrator.
    A reliable interface between PLC outputs and actuators, with standard numbering.
    Panel builder.
    Plug-in relay in a socket – fast installation and easy maintenance.
    Maintenance technician.
    Replace a faulty relay in seconds without disconnecting wires.

    Practical application

    If a PLC 24 V DC output has to switch on a contactor with a 230 V AC coil, the PLC output connects to relay coil A1–A2 and the contactor coil goes through the relay NO contact (11–14). A second contact set can return a status signal to a PLC input.

    Pros

    • Galvanic isolation of control and load circuits
    • Plug-in mounting – fast replacement
    • Standard contact numbering
    • Wide choice of sockets and accessories
    • Low coil power – 0.45 W
    • Mechanical life 30 × 10⁶ cycles

    Cons / limitations

    • No LED or test button
    • NC contact current up to 4 A
    • Not a protective device – does not protect against overload or short circuit
    • Inductive loads need a suppression circuit (diode, RC or varistor)
    • Use a contactor for motors and large loads

    Safety and installation notes

    • Disconnect the supply before installation and verify absence of voltage.
    • Check coil voltage and type (AC/DC) – a wrong coil will not operate or will burn out.
    • Suppress inductive loads (coils, valves) with a diode (DC) or RC circuit / varistor (AC).
    • Protect the contact circuit with a circuit breaker or fuse.
    • Do not exceed rated current and voltage; in DC circuits allow for the lower breaking current.

    Quick selection guide

    2CO
    8 A / 250 V AC
    24 V DC · 0.45 W
    RSZE1S48M
    Suitable when you need:
    • to switch a 230 V load from a 24 V DC PLC output
    • to multiply control contacts
    • to isolate circuits at different voltages
    Check before use:
    • coil voltage and type (AC or DC)
    • load type and current (resistive, inductive, LED)
    • that you have a compatible socket: Schneider Electric RSZE1S48M
    Important reminder: an interface relay is not a protective device. It does not protect against overload or short circuit, and motors and large loads require a contactor.

    FAQ

    Do I need a socket?
    Yes, a plug-in relay needs a socket for DIN rail mounting; compatible: Schneider Electric RSZE1S48M.
    Can the coil be powered at another voltage?
    No, the coil must match the control voltage and type – 24 V DC.
    Is it suitable for driving a contactor coil?
    Yes, that is one of the most common uses; a suppression circuit is recommended.
    Can a motor be connected directly?
    No, connect the motor through a contactor with thermal protection; the relay drives the contactor coil.
    What does 2CO mean?
    It is the number of changeover contact sets; each has COM, NC and NO.
    Do you help with selection?
    Yes, send us a diagram or equipment list – we will select relays, sockets and contactors.

    Interface relay | 2CO | 8 A | coil 24 V DC | plug-in | Schneider Electric RSB2A080BD

    Schneider Electric RSB2A080BD – interface relay with 24 V DC coil and 2CO contacts 8 A, for signal isolation, contact multiplication and control of contactors and valves in automation and electrical panels.

    Published: 2026-11-05 · Data verified against the manufacturer datasheet: 2026-11-05

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Interface relay | 2CO | 8 A | coil 230 V AC | plug-in / PCB | Finder 40.52.8.230.0000
    Code: 40.52.8.230.0000

    Finder 40.52.8.230.0000 – interface relay with 2CO contacts (8 A) and 230 V AC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.

    Price 3.91 € VAT incl.
    ( 3.23 € VAT excl. )
    Interface relay | 2CO | 10 A | coil 24 V DC | plug-in | OMRON LY2N 24 V DC
    Code: LY2N 24VDC

    OMRON LY2N 24 V DC – interface relay with 2CO contacts (10 A) and 24 V DC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.

    Price 6.05 € VAT incl.
    ( 5.00 € VAT excl. )
  • privacy policy