LED panel for installation in "Armstrong" ceiling | 80W | 1195x595x14mm | 4000K | 9600lm | IP20/IP44 | Philips
Code: PHILIPS80WPrice 96.27 € VAT incl.( 79.56 € VAT excl. )This LED panel, designed for installation in Armstrong-type ceilings, is an excellent choice for modern and energy-efficient lighting. Philips technology ensures reliable quality and durability, while the soft 4000K neutral white light provides a cozy and functional illumination. With its ultra-thin design (14 mm) and high light efficiency (9600lm), this LED panel is perfect for offices, schools, hospitals, and other commercial and residential spaces.
-
Technical Specifications:
Power: 80W
Luminous Flux: 9600 lm
Color Temperature: 4000K (neutral white light)
Beam Angle: 120°
Color Rendering Index (CRI): >80
Energy Efficiency: E
Power Factor (PF): ≥0.96
Protection Class: IP20 (indoor) / IP44 (dust and moisture protection)
Mechanical Impact Resistance: IK07 (impact protection)
Voltage: AC220-240V
Frequency: 50/60Hz
Lifespan: Up to 50,000 hours
Dimensions: 1195x595x14 mm
Certifications: CE, RoHS, ErP
EEI Class: E
Usage:Offices, conference rooms, shopping centers.
Public spaces: Schools, libraries, hospitals.
Kitchens, workrooms, or other areas requiring bright, neutral lighting.
Pros:Energy Saving: Efficient LED light source reduces energy costs compared to traditional lighting.
Longevity: Up to 50,000 hours lifespan, fewer replacements, and lower maintenance costs.
Aesthetic Design: Slim body (14 mm) provides a modern and minimalist look.
Functionality: Neutral white light (4000K) is suitable for both work and general lighting.
Certifications: Complies with CE, RoHS, ErP standards, ensuring quality and environmental requirements.
Cons:Protection Class IP20/IP44: Not suitable for areas with high humidity or constant water contact.
Energy Efficiency Class E: Does not meet the highest efficiency standards compared to newer LED products.
Mounting Restrictions: Designed only for Armstrong-type ceilings or similar systems.
This LED panel is a reliable and functional lighting solution suitable for various commercial and residential projects where energy savings and aesthetic design are important.Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerMounting typeSurface mount typeThe IP protection class indicates the device's resistance to environmental factors.

The first digit indicates protection against dust and solid objects.
The second digit indicates protection against moisture.First digit values:
X — Untested;
0 — No protection;
1 — Protected against solid objects larger than 50 mm;
2 — Protected against solid objects larger than 12.5 mm;
3 — Protected against solid objects larger than 1 mm;
4 — Protected against solid objects larger than 1 mm;
5 — Dust protected;
6 — Totally dustproof.
Second digit values:X — Untested;
0 — No protection;
1 — Protected against vertically falling water drops;
2 — Protected against water drops falling at a 15º angle;
3 — Protected against rain falling at a 60º angle;
4 — Protected against water splashes;
5 — Protected against water jets;
6 — Protected against large amounts of water;
7 — Protected against short-term immersion in water up to 1 meter deep;
8 — Protected against long-term immersion in water up to 3 meters deep.Lumen (lm) – unit of luminous flux: how much light a lamp or luminaire emits in total. Lux (lx) – illuminance: how much of that light falls on 1 m² of surface (1 lx = 1 lm/m²). Watts (W) only show power consumption – compare LED brightness by lumens.
How many lux does a room need?
Corridor, storeroom, basement 100–150 lx Living room, bedroom 100–300 lx Garage, warehouse 100–200 lx Kitchen, bathroom, desk 300–500 lx Office, computer workstation 500 lx Workshop, fine work 500–750 lx How to calculate the lumens you need
Required lumens ≈ illuminance (lx) × area (m²) ÷ 0.5
The 0.5 factor accounts for light absorbed by walls, ceiling and diffusers and for luminaires getting dirty over time. Example: 18 m² garage, 200 lx → 200 × 18 ÷ 0.5 = 7,200 lm. That is about three 150 cm T8 LED tubes of ~2,500 lm each.
This is an estimate. For an exact design (workplaces, production, public areas) use lighting calculation software, e.g. DIALux.
Recommended values are indicative, based on the principles of EN 12464-1 for workplace lighting.
Beam angle – this is the angle at which light spreads on the floor. By selecting the correct beam angle for a light fixture or lamp, the room will be adequately lit.
When choosing a light fixture’s beam angle, consider the following factors:
The primary lighting of the room, which covers the entire space. In bedrooms, living rooms, garages, and bathrooms, the light fixture beam angle should be between 120° to 90°, depending on the size of the room.
Accent lighting, which illuminates a specific part of the room. Fixtures with narrower beam angles are used for this type of lighting.
Decorative lighting, which highlights a desired object. Narrow or very narrow beam angle fixtures are used for this purpose.
The type of building. Rooms with high ceilings and smaller spaces need fewer fixtures with narrower beams. Rooms with lower ceilings and larger spaces require light fixtures with wider beam angles. For rooms with a ceiling height of 2.4 to 2.7 m, a fixture with a wider beam angle of 60° is needed.
In residential buildings, it is recommended to choose light fixtures with a beam angle of 40° to 60°. However, for larger rooms, it is better to choose a beam angle greater than 60°.
For specific objects (stairs, closets, kitchen cabinets), a narrower beam angle of around 25° is suitable.
In offices, where people spend most of their time at computers, narrower beam angle fixtures are necessary to ensure higher intensity.
In warehouses with high ceilings, it is worth choosing several fixtures with a narrower beam angle. To install wide beam fixtures, it is better to mount them on the wall.
Retail stores require bright and intense light, which is achieved with fixtures that have narrower beam angles. A wider beam may be used to illuminate the entire store.
In restaurants, it is recommended to use narrow beam light. To highlight the décor, narrow beams from 10° to 25° are used.
Application of beam angle:A narrow beam angle illuminates a smaller area but emits more intense light.
A medium beam angle is applied in living areas but is also ideal for lighting in clothing stores and commercial spaces.
A wide beam angle is suitable for outdoor lighting, for example, to light a large commercial store.
A very wide beam angle is used for outdoor floodlights and street lighting.
To calculate how many and what type of light fixtures you need for your desired space, visit this website: https://www.dialux.com/en-GB/download.3 main types of white light:
Warm white (2700 - 3000 K)
Neutral white / daylight (4000 - 4500 K)
Cool white (5000 - 6500 K)
How to choose the right light color temperature:2700 - 3000K creates a cozy atmosphere in a room. Used in spas, hotel entrances, living rooms, and bedrooms.
4000 - 4500K is used in commercial, retail, office spaces, garages, medical buildings, as well as bathrooms, kitchens, and workrooms.
5000 - 6500K is suitable for lighting workshops, operating rooms, or other areas where attention to detail is important. Also suitable for outdoor lighting, modern interiors, and their accents.
To calculate how many and what type of light fixtures are needed for your desired space, visit this website: https://www.dialux.com/en-GB/download.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products