Products catalog

  • Metal halide lamp RX7s | 150W | 96V | 3000K | 13400lm | MHN-TD 150W/730 Philips

    Code: 93506
    Barcode: 8711500193506

    Philips MHN-TD 150W/730 RX7s – double-ended metal halide lamp: 13,400 lm, 3000 K, CRI 67. For enclosed 150 W RX7s luminaires, operated via a ballast and ignitor.

  • Metal halide lamp RX7s | 150W | 96V | 3000K | 13400lm | MHN-TD 150W/730 Philips

    Philips MHN-TD 150W/730 is a double-ended (RX7s) quartz metal halide lamp delivering 13,400 lm of warm white 3000 K light. It is intended for enclosed floodlights and luminaires designed for a 150 W metal halide lamp. It operates only via a ballast and ignitor – it must not be connected directly to the 230 V mains.

    Key point:
    This is a replacement lamp for existing 150 W RX7s metal halide luminaires – in shops, halls and on façades. Three things must match: wattage (150 W), cap (RX7s) and lamp type (metal halide, not an R7s halogen incandescent). Then the ballast and luminaire stay the same and the light is exactly as before.
    Power
    150 W (consumption 155 W)
    Luminous flux
    13,400 lm, 90 lm/W
    Light colour
    3000 K, CRI 67
    Cap
    RX7s, length 135.4 mm

    Operating principle

    The lamp is fitted into RX7s lampholders in an enclosed luminaire; operating position is horizontal or up to ±45° from horizontal (P45).

    When switched on, the ignitor strikes the arc in the quartz burner with a high-voltage pulse, and the ballast limits the current. 96 V is the nominal arc voltage of the running lamp, not the supply voltage. Like all metal halide lamps, it reaches full output after a few minutes, and a hot lamp restrikes only after cooling down.

    The result is 13,400 lm of warm white light from a compact 17.8 mm arc that the reflector directs precisely onto the target area.

    Why choose MHN-TD 150W/730?
    Replacing a failed lamp in the same luminaire keeps the illuminance and light tone unchanged – no need to replace the ballast, ignitor or the whole luminaire.

    Technical specifications

    Product type Double-ended quartz metal halide lamp (HID)
    Manufacturer Philips (Signify)
    Model MHN-TD 150W/730 RX7s 1CT
    EAN 8711500193506
    Nominal power 150 W
    Power consumption 155 W
    Nominal lamp (arc) voltage 96 V
    Luminous flux 13,400 lm
    Luminous efficacy 90 lm/W (nom.), 81 lm/W (min.)
    Colour temperature 3000 K, warm white
    Colour rendering index (CRI) 67
    Cap RX7s
    Bulb TD, clear, quartz
    Operating position P45 – horizontal ±45°
    Length (max) 135.4 mm
    Diameter (max) 23.0 mm
    Arc length 17.8 mm
    Lifetime (50% failures) 10,500 h
    Bulb temperature (max) 650 °C
    Pinch temperature (max) 280 °C
    Mercury content 18 mg
    Dimmable No
    Energy efficiency class G (EPREL 473287)
    Energy consumption 155 kWh / 1000 h
    Luminaire Totally enclosed only (IEC 61167, IEC 62035, IEC 60598)

    Main features

    • 13,400 lm from a single lamp – lights large areas with fewer luminaires
    • Warm white 3000 K – pleasant light for retail and representative spaces
    • Compact 17.8 mm arc – precise beam control with the floodlight reflector
    • RX7s cap, 135.4 mm – fits standard 150 W RX7s luminaires
    • P45 position – mounting flexibility in floodlights and tiltable luminaires
    • 10,500 h lifetime – less frequent replacement in high-mounted luminaires

    Where is it used?

    • Retail halls and shop windows
    • Exhibition and event halls
    • Façade and building floodlights
    • Sports halls and small arenas
    • High-ceiling warehouses and production areas
    • Car showrooms and displays
    • Service and repair of existing metal halide floodlights

    Use by need

    For electricians and maintenance companies.
    Fast replacement of a failed lamp in an existing luminaire without changing the ballast or wiring.
    For shop or facility managers.
    Uniform light tone across the whole hall when only some lamps are replaced.
    For lighting designers.
    Known photometric data (13,400 lm, 3000 K, CRI 67) for auditing and calculating legacy systems.

    Practical application

    If one 150 W RX7s floodlight in a hall has gone out while the others give warm white light, replace the lamp with MHN-TD 150W/730 – wattage, cap and colour match, and the ballast and ignitor remain the same. If the new lamp does not start or flickers, check the ignitor and ballast – they are often the real cause of the failure.

    Pros

    • High output – 13,400 lm, 90 lm/W
    • Warm white 3000 K light
    • Compact lamp, easily controlled beam
    • Fits existing 150 W RX7s luminaires without modification
    • 10,500 h lifetime (50% failures)
    • Manufacturer data registered in the EPREL database

    Cons / limitations

    • CRI 67 – where accurate colour rendering matters, choose ceramic burner (CDM) lamps with a higher CRI
    • Not dimmable
    • Takes a few minutes to run up; a hot lamp restrikes only after cooling
    • Enclosed luminaires only
    • Energy class G, contains 18 mg mercury – for new projects consider LED floodlights

    Safety and installation notes

    • Switch off the power and let the lamp cool before replacing – the bulb reaches up to 650 °C.
    • Do not touch the quartz bulb with bare hands; if touched, clean it with alcohol.
    • Use only in a totally enclosed luminaire with a protective glass – even during testing (IEC 61167, IEC 62035, IEC 60598).
    • The ballast must be rated for a 150 W metal halide lamp; control gear with EOL (end-of-life) protection is recommended.
    • Do not connect directly to 230 V mains – a ballast and ignitor are required.
    • Do not mount at more than ±45° from horizontal.
    • If the lamp breaks, ventilate the room, collect the fragments without a vacuum cleaner and dispose of them as hazardous waste.

    Quick selection guide

    150 W
    RX7s
    3000 K
    13,400 lm
    96 V arc voltage
    P45 ±45°
    Suitable when you need:
    • to replace a 150 W RX7s metal halide lamp in an existing luminaire
    • to keep warm white 3000 K light
    • high luminous flux from a compact source
    Check before use:
    • the wattage and type of the old lamp (MHN / MHW / HQI, not an R7s halogen)
    • that the ballast is rated for a 150 W metal halide lamp
    • that the luminaire is enclosed with a protective glass
    • that the ~135 mm lamp fits the lampholders
    Important reminder: this is neither an R7s halogen incandescent nor an LED lamp. It will not work in an R7s halogen floodlight without a ballast, and a halogen bulb must not be fitted into a metal halide luminaire.

    FAQ

    Can it be connected directly to 230 V?
    No – it requires a ballast with ignitor rated for 150 W metal halide lamps, or an electronic HID ballast.
    What does 96 V mean?
    It is the nominal arc voltage of the running lamp; the luminaire is supplied from the normal mains via the ballast.
    Can it replace a 150 W R7s halogen bulb?
    No – it works on a different principle and needs a metal halide luminaire with a ballast.
    Can the brightness be dimmed?
    No, the manufacturer specifies the lamp as non-dimmable.
    Why does the lamp not restart immediately after switching off?
    A hot metal halide lamp must cool down before it restrikes – this is normal for this lamp type.
    Can it be used in an open luminaire?
    No – the manufacturer permits use only in totally enclosed luminaires, even during testing.

    Metal halide lamp RX7s | 150W | 96V | 3000K | 13400lm | MHN-TD 150W/730 Philips

    Philips MHN-TD 150W/730 RX7s – 150 W double-ended metal halide lamp, 13,400 lm, 3000 K, for enclosed floodlights and luminaires in retail, exhibition, sports and production spaces. Order at elsprendimai.eu or collect in Šiauliai, J. Basanavičiaus g. 23, Lithuania.

    Published: 2025-06-03 · Data verified against the manufacturer datasheet: 2026-11-17

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Price 1.39 € VAT incl.
    ( 1.15 € VAT excl. )
  • privacy policy

    Information