Products catalog

  • Metal halide lamp RX7s | 70W | 94V | 3000K | 6000lm | MASTER CDM-TD 70W/830 Philips

    Code: 82515
    Barcode: 871150019782515

    Philips CDM-TD 70W/830 RX7s – double-ended metal halide lamp: 6,000 lm, 3000 K, CRI 80. For enclosed 70 W RX7s luminaires, operated via a ballast and ignitor.

  • Metal halide lamp RX7s | 70W | 94V | 3000K | 6000lm | MASTER CDM-TD 70W/830 Philips

    Philips CDM-TD 70W/830 is a double-ended (RX7s) ceramic burner metal halide lamp delivering 6,000 lm of warm white 3000 K light. It is intended for enclosed floodlights and luminaires designed for a 70 W metal halide lamp. It operates only via a ballast and ignitor – it must not be connected directly to the 230 V mains.

    Key point:
    This is a replacement lamp for existing 70 W RX7s metal halide luminaires. Three things must match: wattage (70 W), cap (RX7s) and lamp type (metal halide, not an R7s halogen incandescent). Then the ballast and luminaire stay the same. The ceramic burner gives higher colour rendering (CRI 80) and stable colour over the whole lifetime.
    Power
    70 W (consumption 71 W)
    Luminous flux
    6,000 lm, 85 lm/W
    Light colour
    3000 K, CRI 80
    Cap
    RX7s, length 119.63 mm

    Operating principle

    The lamp is fitted into RX7s lampholders in an enclosed luminaire; operating position is horizontal or up to ±45° from horizontal (P45).

    When switched on, the ignitor strikes the arc in the ceramic burner with a high-voltage pulse, and the ballast limits the current. 94 V is the nominal arc voltage of the running lamp, not the supply voltage. Like all metal halide lamps, it reaches full output after a few minutes, and a hot lamp restrikes only after cooling down.

    The result is 6,000 lm of warm white light from a compact source that the luminaire reflector directs onto the target area.

    Why choose CDM-TD 70W/830?
    Replacing a failed lamp in the same luminaire keeps the illuminance and light tone unchanged – no need to replace the ballast, ignitor or the whole luminaire.

    Technical specifications

    Product type Double-ended metal halide lamp with ceramic burner (HID)
    Manufacturer Philips (Signify)
    Model MASTERColour CDM-TD 70W/830 RX7s 1CT/12
    EAN 8711500197825
    Nominal power 70 W
    Power consumption 71 W
    Nominal lamp (arc) voltage 94 V
    Lamp current 0.95 A
    Luminous flux 6,000 lm
    Luminous efficacy 85 lm/W
    Colour temperature 3000 K, warm white
    Colour rendering index (CRI) 80
    Cap RX7s
    Bulb clear, ceramic burner
    Operating position P45 – horizontal ±45°
    Length 119.63 mm
    Diameter 22 mm
    Arc length 8 mm
    Lifetime (50% failures) 16,000 h
    Bulb temperature (max) 500 °C
    Pinch temperature (max) 280 °C
    Mercury content 3.4 mg
    Dimmable No
    Energy efficiency class G
    Energy consumption 71 kWh / 1000 h
    Weight 21 g
    Luminaire Totally enclosed only (IEC 61167, IEC 62035, IEC 60598)

    Main features

    • 6,000 lm from a single lamp – lights large areas with fewer luminaires
    • Warm white 3000 K – pleasant light for retail and representative spaces
    • CRI 80 – more natural rendering of goods and interior colours
    • RX7s cap – fits standard 70 W RX7s luminaires
    • P45 position – mounting flexibility in floodlights and tiltable luminaires
    • 16,000 h lifetime – less frequent replacement in high-mounted luminaires

    Where is it used?

    • Retail halls and shop windows
    • Exhibition and event halls
    • Façade and building floodlights
    • Museums and displays
    • Hotel lobbies and representative spaces
    • Service and repair of existing metal halide floodlights

    Use by need

    For electricians and maintenance companies.
    Fast replacement of a failed lamp in an existing luminaire without changing the ballast or wiring.
    For shop or facility managers.
    Uniform light tone across the whole hall when only some lamps are replaced.
    For lighting designers.
    Known parameters (6,000 lm, 3000 K, CRI 80) for auditing existing systems.

    Practical application

    If one 70 W RX7s floodlight has gone out while the others give warm white light, replace the lamp with CDM-TD 70W/830 – wattage, cap and colour match, and the ballast and ignitor remain the same. If the new lamp does not start or flickers, check the ignitor and ballast – they are often the real cause of the failure.

    Pros

    • High output – 6,000 lm, 85 lm/W
    • Warm white 3000 K light
    • Higher colour rendering – CRI 80
    • Stable colour over lifetime
    • Compact lamp, easily controlled beam
    • Fits existing 70 W RX7s luminaires without modification
    • 16,000 h lifetime

    Cons / limitations

    • Not dimmable
    • Takes a few minutes to run up; a hot lamp restrikes only after cooling
    • Enclosed luminaires only
    • Contains mercury – for new projects consider LED floodlights

    Safety and installation notes

    • Switch off the power and let the lamp cool before replacing – the bulb reaches up to 500 °C.
    • Do not touch the bulb with bare hands; if touched, clean it with alcohol.
    • Use only in a totally enclosed luminaire with a protective glass – even during testing (IEC 61167, IEC 62035, IEC 60598).
    • The ballast must be rated for a 70 W metal halide lamp; control gear with EOL (end-of-life) protection is recommended.
    • Do not connect directly to 230 V mains – a ballast and ignitor are required.
    • Do not mount at more than ±45° from horizontal.
    • If the lamp breaks, ventilate the room, collect the fragments without a vacuum cleaner and dispose of them as hazardous waste.

    Quick selection guide

    70 W
    RX7s
    3000 K
    6,000 lm
    94 V arc voltage
    P45 ±45°
    Suitable when you need:
    • to replace a 70 W RX7s metal halide lamp in an existing luminaire
    • warm white 3000 K light
    • high luminous flux from a compact source
    Check before use:
    • the wattage and type of the old lamp (MHN / MHW / HQI / CDM, not an R7s halogen)
    • that the ballast is rated for a 70 W metal halide lamp
    • that the luminaire is enclosed with a protective glass
    • that the lamp length fits the lampholders
    Important reminder: this is neither an R7s halogen incandescent nor an LED lamp. It will not work in an R7s halogen floodlight without a ballast, and a halogen bulb must not be fitted into a metal halide luminaire.

    FAQ

    Can it be connected directly to 230 V?
    No – it requires a ballast with ignitor rated for 70 W metal halide lamps, or an electronic HID ballast.
    What does 94 V mean?
    It is the nominal arc voltage of the running lamp; the luminaire is supplied from the normal mains via the ballast.
    Can it replace a 70 W R7s halogen bulb?
    No – it works on a different principle and needs a metal halide luminaire with a ballast.
    Can the brightness be dimmed?
    No, the lamp is not dimmable.
    Why does the lamp not restart immediately after switching off?
    A hot metal halide lamp must cool down before it restrikes – this is normal for this lamp type.
    Can it be used in an open luminaire?
    No – only in totally enclosed luminaires, even during testing.

    Metal halide lamp RX7s | 70W | 94V | 3000K | 6000lm | MASTER CDM-TD 70W/830 Philips

    Philips CDM-TD 70W/830 RX7s – 70 W double-ended metal halide lamp, 6,000 lm, 3000 K, for enclosed floodlights and luminaires. Order at elsprendimai.eu or collect in Šiauliai, J. Basanavičiaus g. 23, Lithuania.

    Published: 2025-06-03 · Data verified against the manufacturer datasheet: 2026-11-17

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Price 1.39 € VAT incl.
    ( 1.15 € VAT excl. )
  • privacy policy