  • Miniature circuit breaker | 1P | 10A | C | 4.5kA | DIN | MCB | Merlin Gerin | Multi9 C60a | 23850

    Code: 23850
  • Miniature circuit breaker | 1P | 10A | C | 4.5kA | DIN | MCB | Merlin Gerin | Multi9 C60a | 23850

    Merlin Gerin (Schneider Electric) Multi9 C60a series 1-pole miniature circuit breaker, 10 A, C curve. It protects the circuit against overload and short circuit and mounts on a 35 mm DIN rail. C60a is the residential and commercial version of the Multi9 range.

    Key point:
    Multi9 C60a breakers are still installed in many panels. When one fails, the same code 23850 keeps the panel uniform and fits the existing busbars and accessories (Vigi C60, auxiliary contacts).
    Poles / current
    1P / 10 A
    Curve
    C
    Breaking capacity
    4500 A (EN 60898)
    Voltage
    230/400 V AC

    Operating principle

    The breaker clips onto a DIN rail; wires connect to screw terminals. In normal operation it simply carries the current.

    The thermal release reacts to sustained overload, the magnetic release to short circuit. The C curve trips at 5–10 × In, suitable for general-purpose circuits.

    After tripping the breaker stays in the OFF position and is reset manually once the fault is cleared.

    Why choose 23850?
    It is an exact match for the original Multi9 C60a breaker – no need to rebuild the panel or change busbars.

    Technical specifications

    Product typeMiniature circuit breaker (MCB)
    Manufacturer / seriesMerlin Gerin (Schneider Electric) / Multi9 C60a
    Manufacturer code23850
    Number of poles1P
    Rated current In10 A
    Tripping curveC curve (5–10 × In per EN 60898)
    Rated operational voltage Ue230/400 V AC
    Frequency50/60 Hz
    Breaking capacity Icn (EN 60898)4500 A
    Breaking capacity Icu (IEC 60947-2)5 kA
    Series current range6–40 A
    Mounting35 mm DIN rail, clip-on
    Width / height18 mm / 81 mm
    StandardsEN 60898, IEC 60947-2
    Product statusDiscontinued by the manufacturer; current Schneider equivalent – Acti9 iC60 series

    Main functions

    • Overload protection – disconnects the circuit before cables overheat.
    • Short-circuit protection – the C-curve magnetic release acts instantly.
    • Compact – takes one module in the panel.
    • Compatibility – fits Multi9 busbars and accessories.
    • Position indication – the lever clearly shows ON/OFF.

    Where is it used?

    • Lighting and socket circuits
    • Single-phase 230 V circuits
    • Existing distribution panels with Multi9 C60a equipment
    • Commercial building and production panels
    • Replacing a failed breaker with the same code
    • Repair and maintenance work

    Use by need

    For facility managers.
    Only the failed breaker is replaced; the panel and documentation stay the same.
    For electricians.
    Same C60a housing – no need to cut busbars or replace neighbouring devices.
    For purchasing.
    Order this discontinued code together with other electrical items, with a VAT invoice.

    Practical use

    If 23850 fails in a panel with Multi9 equipment and identical breakers sit next to it, you replace it with the same code – busbar, labelling and panel diagram remain unchanged.

    Advantages

    • Original Merlin Gerin code
    • Breaking capacity 4500 A per EN 60898
    • Fits Multi9 busbars and accessories
    • Complies with EN 60898 and IEC 60947-2
    • Pickup available in Šiauliai

    Disadvantages / limitations

    • Discontinued – for new panels choose Acti9 iC60
    • No residual current protection – a separate RCD is required
    • C60a has lower breaking capacity than C60N/C60H – not for locations with high short-circuit current

    Safety and installation notes

    • Installation only by a qualified electrician, with power off and absence of voltage verified.
    • Poles, current and curve must match the breaker being replaced.
    • The breaker current must not exceed the cable current rating.
    • Short-circuit current at the installation point must not exceed 4500 A.
    • Tighten terminals properly – a loose contact heats up.

    Quick selection guide

    1P
    10 A
    C curve
    4500 A
    Multi9 C60a
    Suitable when you need:
    • to replace a Multi9 C60a breaker with the same code;
    • 1P, 10 A, C-curve protection.
    Check before use:
    • the old breaker code and curve;
    • supply voltage and short-circuit current;
    • cable cross-section and terminal type.
    Important reminder: a circuit breaker does not replace a residual current device (RCD) or surge protector – these are separate protective devices.

    FAQ

    Is this an original Merlin Gerin breaker?
    Yes, Merlin Gerin (Schneider Electric) Multi9 C60a, code 23850.
    What replaces it if I need a current model?
    The current Schneider equivalent is the Acti9 iC60 series.
    Does it fit a DIN rail?
    Yes, it mounts on a 35 mm DIN rail.
    What does 4500 A mean?
    It is the breaking capacity per EN 60898 – the highest short-circuit current the breaker can safely interrupt.
    Does it protect against electric shock?
    No, that requires a residual current device (RCD).
    Can I pick it up in Šiauliai?
    Yes, J. Basanavičiaus g. 23, Šiauliai.

    Miniature circuit breaker | 1P | 10A | C | 4.5kA | DIN | MCB | Merlin Gerin | Multi9 C60a | 23850

    Original Merlin Gerin Multi9 C60a miniature circuit breaker 23850: 1P, 10 A, C curve, 4500 A per EN 60898. For replacing a failed breaker in an existing panel.