Miniature circuit breaker | 1P | 5A | C | AC/DC | UL489 | DIN | Merlin Gerin | Multi9 C60 | 60106
Code: 60106Price 25.00 € VAT incl.( 20.66 € VAT excl. )-
Miniature circuit breaker | 1P | 5A | C | AC/DC | UL489 | DIN | Merlin Gerin | Multi9 C60 | 60106
Merlin Gerin (Schneider Electric) Multi9 C60 UL489 series 1-pole miniature circuit breaker, 5 A, C curve. It protects the circuit against overload and short circuit and mounts on a 35 mm DIN rail. This version is certified to UL 489 and CSA C22.2 No 5, so it is most often found in equipment made in the USA and Canada.
Key point:
When a breaker fails in a UL-certified machine, it is best replaced with the same code – no need to approve a substitute with the equipment maker or insurer. Code 60106 is no longer produced, so it is getting harder to find on the market.Poles / current
1P / 5 ACurve
C (8.5 × In)Breaking capacity
10 kA (120 V AC, CSA)Voltage
240 V AC; 60 V DCOperating principle
The breaker clips onto a DIN rail; wires connect to tunnel terminals from the top or bottom. Its job is to disconnect the circuit automatically when the current exceeds the permitted value.
The thermal release reacts to sustained overload, the magnetic release to short-circuit current. The C-curve magnetic release trips at 8.5 × In ±20 % (AC); 12 × In ±20 % (DC).
After tripping, the lever shows OFF, making the fault easy to locate; once the cause is removed, the breaker is reset manually.
Why choose 60106?
It is an original UL489 breaker with the exact code shown on the US or Canadian equipment diagram. The C curve suits most control and power circuits.Technical specifications
Product type Miniature circuit breaker (MCB) Manufacturer / series Merlin Gerin (Schneider Electric) / Multi9 C60 UL489 Manufacturer code 60106 Number of poles 1P (1 protected pole) Rated current In 5 A (at 25 °C) Tripping curve C Magnetic tripping limit 8.5 × In ±20 % (AC); 12 × In ±20 % (DC) Rated operational voltage Ue 240 V AC; 60 V DC Frequency 50/60 Hz Breaking capacity CSA C22.2 No 5.2: 10 kA (120 V AC), 5 kA (240 V AC), 10 kA (60 V DC); EN/IEC 60947-2: Icu 10 kA (60 V DC) Limitation class 3 (EN/IEC 60947-2) Rated impulse withstand voltage Uimp 6 kV Suitable for isolation Yes (EN/IEC 60947-2) Terminals Tunnel terminals, top or bottom, 2.5–25 mm² (AWG 14–4), stripping length 14 mm Mounting 35 mm DIN rail, clip-on Dimensions (W × H × D) 18 × 107 × 73 mm Weight 0.11 kg Degree of protection IP20 (terminals); IP40 in modular enclosure Operating temperature −30…+70 °C Mechanical / electrical durability 20,000 / 10,000 cycles Other features ON/OFF position indication, padlockable Standards UL 489, CSA C22.2 No 5, EN/IEC 60947-2 Product status Discontinued by the manufacturer; Schneider recommended replacement – Multi9 C60BP / C60BPR Main functions
- Overload protection – the thermal release disconnects the circuit before cables overheat.
- Short-circuit protection – the C-curve magnetic release trips within milliseconds.
- DC capable – up to 60 V DC, suitable for control and battery circuits.
- Isolation function – suitable for safe isolation per EN/IEC 60947-2.
- Padlocking – the lever can be locked during maintenance.
- Original code – no changes to the diagram or equipment documentation.
Where is it used?
- Electrical cabinets of UL-certified US and Canadian machine tools, compressors and packaging lines
- Control, signalling and PLC power circuits
- DC circuits up to 60 V: 24 V DC control, battery systems
- Protection of industrial power supplies and drive control sections
- Replacing an original Merlin Gerin C60 breaker in a faulty panel without rework
- Equipment repair where documentation specifies this exact code
Use by need
For maintenance technicians.
You get the same code 60106 shown on the machine diagram – no substitute approval needed.For panel builders.
The same Multi9 C60 housing fits existing busbars and DIN rail.For purchasing.
Order this discontinued UL489 breaker together with other electrical items, with a VAT invoice for your company.Practical use
If breaker 60106 in the cabinet of a US-made machine has tripped and will not reset, and the diagram specifies this exact code, you replace it with the same one – no rewiring, no substitute approval and no change to compliance documents.Advantages
- Original Merlin Gerin / Schneider code
- Certified to UL 489 and CSA C22.2 No 5
- Works in AC and DC circuits (up to 60 V DC)
- Suitable for isolation, padlockable
- Wide operating temperature range: −30…+70 °C
- Pickup available in Šiauliai
Disadvantages / limitations
- Discontinued – for new projects choose Multi9 C60BP / C60BPR or Acti9 iC60
- Rated current calibrated at 25 °C (UL), not 30 °C as with European MCBs
- Single pole: only 5 kA breaking capacity at 240 V AC (CSA)
- No residual current protection – a separate RCD is required
Safety and installation notes
- Installation and replacement only by a qualified electrician, with power off and absence of voltage verified.
- Before replacing, compare the old breaker code, poles, current and curve – they must match.
- Do not choose a higher current than the cable cross-section allows.
- Check that the prospective short-circuit current does not exceed the breaker breaking capacity (5 kA (240 V AC)).
- In DC circuits observe the polarity and voltage limit specified by the manufacturer.
- Tighten terminals to the correct torque – a loose terminal heats up.
Quick selection guide
1P5 AC curveAC/DCUL 489Multi9 C60Suitable when you need:- to replace a failed Merlin Gerin C60 breaker with the same code 60106;
- a UL489-certified breaker for US or Canadian equipment;
- 1P, 5 A, C-curve protection.
Check before use:- the old breaker code and curve;
- supply voltage and short-circuit current;
- cable cross-section and terminal type.
Important reminder: a circuit breaker does not replace a residual current device (RCD) or surge protector – these are separate protective devices.FAQ
Is this an original Merlin Gerin breaker?
Yes, it is a Merlin Gerin (Schneider Electric) Multi9 C60 UL489 series breaker, code 60106.How does it differ from the European C60N?
It is certified to UL 489 and CSA, and its rated current is calibrated at 25 °C.Can it be used for DC?
Yes, the manufacturer specifies up to 60 V DC.What replaces it if I need a current model?
Schneider recommended replacement – Multi9 C60BP / C60BPR.Does it fit a standard DIN rail?
Yes, it mounts on a 35 mm DIN rail.Can I pick it up in Šiauliai?
Yes, you can collect it at our office, J. Basanavičiaus g. 23, Šiauliai.Miniature circuit breaker | 1P | 5A | C | AC/DC | UL489 | DIN | Merlin Gerin | Multi9 C60 | 60106
Original Merlin Gerin Multi9 C60 UL489 circuit breaker 60106: 1P, 5 A, C curve, 240 V AC; 60 V DC. For electrical cabinets and control circuits of US and Canadian equipment, DIN rail mounting.
Published: 2026-11-20 · Data verified against the manufacturer datasheet: 2026-11-20
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerCircuit breakers, also known as protective breakers or circuit interrupters, are essential components of electrical protection systems. They automatically disconnect the electrical circuit when it becomes overloaded or when a short circuit occurs. They are used in electrical installations to protect equipment and people from electrical faults. Circuit breakers come in various types and have different characteristics depending on the installation location, circuit load, and other specifications.
Circuit Breaker Characteristics:
B, C, and D Characteristics:
B characteristic: Used in residential areas or low-load systems. They operate when the current exceeds the nominal current by 3 to 5 times.
C characteristic: Commonly used in both residential and commercial or industrial spaces. Their operating threshold is 5 to 10 times the nominal current, making them suitable for loads with high inrush currents (e.g., motors, lighting systems).
D characteristic: Used in industrial installations where loads have very high inrush currents (e.g., compressors, transformers). They operate when the current exceeds the nominal by 10 to 20 times.
Advantages (Pros) of Circuit Breakers:Safety: Circuit breakers ensure that the circuit is automatically disconnected in case of overload or short circuit, preventing wire burning, equipment damage, or even fires.
Reliability: They are highly reliable and can operate for long periods without maintenance, reacting automatically when electrical faults occur.
Ease of use: There is no need to replace the breaker after it trips. After an overload or short circuit, the circuit breaker can simply be reset to its operational position, avoiding the need to replace fuses.
Precision: Circuit breakers operate accurately according to the nominal current and circuit characteristics, ensuring minimal unnecessary power interruption.
Protection against short circuits and overloads: Breakers not only protect against short circuits but also against prolonged overloads, which can be harmful to electrical systems.
Versatility: There are various types of circuit breakers suitable for different systems, from small household installations to large industrial systems.
Easy reset: After a trip, the breaker can simply be reset without the need to replace it (unlike fuses that need to be replaced after a trip).
Disadvantages (Cons) of Circuit Breakers:High cost: Circuit breakers, especially those with more complex functions (e.g., adjustable protection limits), are more expensive than simple fuses.
Limited operating range: While breakers provide protection against overloads and short circuits, they cannot protect against all types of electrical faults, such as overvoltage. Additional protection devices are required for that.
Larger size: Circuit breakers are generally larger than fuses, meaning their installation may require more space in the distribution panel.
Limited protection against frequent overloads: If the electrical system experiences frequent overloads, circuit breakers may not fully protect equipment from long-term damage caused by continuous overload exposure.
More complex repair: Some complex circuit breakers may require more maintenance or repairs if they malfunction or trip incorrectly.
Applications of Circuit Breakers:Household Installations:
B characteristic breakers are most commonly used in residential installations to protect circuits from short circuits and overloads. They are suitable for lighting circuits, plugs, and other low-load devices.
C characteristic breakers are also used in homes but are better suited for areas with higher inrush currents, such as electric motors or heaters.
Commercial and Industrial Installations:C characteristic breakers are often used in commercial and industrial buildings. They are suitable for electrical equipment with medium inrush currents.
D characteristic breakers are used in industrial equipment where large inrush currents occur, such as for heavy motors, transformers, or high-power equipment protection.
Large Mechanisms and Industrial Equipment:D characteristic breakers are used where the inrush currents are very high. This includes electrical network distribution sections, industrial machinery, and transformers.
Protection of Electronics Equipment:Certain types of circuit breakers are used to protect electronic equipment, such as in server rooms or other sensitive systems where fast and precise protection is required.
Conclusion:
Circuit breakers are essential in modern electrical systems to ensure safe power supply and protection from faults. They have many advantages, such as reliability, safety, and easy resetting, but they also have some drawbacks, such as higher cost and larger size. Their selection depends on the intended use and required protection parameters.K – Trips when the current is 8-12 times higher than the nominal current, designed to protect circuits powering motors, capacitors, and transformers.
S – Trips when the current is 13-17 times higher than the nominal current, designed for the protection of control transformers.
Z – Trips when the current is 2-3 times higher than the nominal current, designed for the protection of computer equipment and other electronic components and devices.
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products