  • Miniature circuit breaker | 2P | 4A | C | AC/DC | UL489 | DIN | Merlin Gerin | Multi9 C60 | 60139

    Code: 60139
  • Miniature circuit breaker | 2P | 4A | C | AC/DC | UL489 | DIN | Merlin Gerin | Multi9 C60 | 60139

    Merlin Gerin (Schneider Electric) Multi9 C60 UL489 series 2-pole miniature circuit breaker, 4 A, C curve. It protects the circuit against overload and short circuit and mounts on a 35 mm DIN rail. This version is certified to UL 489 and CSA C22.2 No 5, so it is most often found in equipment made in the USA and Canada.

    Key point:
    When a breaker fails in a UL-certified machine, it is best replaced with the same code – no need to approve a substitute with the equipment maker or insurer. Code 60139 is no longer produced, so it is getting harder to find on the market.
    Poles / current
    2P / 4 A
    Curve
    C (8.5 × In)
    Breaking capacity
    10 kA (UL 489)
    Voltage
    240 / 415 / 440 V AC; 125 V DC

    Operating principle

    The breaker clips onto a DIN rail; wires connect to tunnel terminals from the top or bottom. Its job is to disconnect the circuit automatically when the current exceeds the permitted value.

    The thermal release reacts to sustained overload, the magnetic release to short-circuit current. The C-curve magnetic release trips at 8.5 × In ±20 % (AC); 12 × In ±20 % (DC).

    After tripping, the lever shows OFF, making the fault easy to locate; once the cause is removed, the breaker is reset manually.

    Why choose 60139?
    It is an original UL489 breaker with the exact code shown on the US or Canadian equipment diagram. The C curve suits most control and power circuits.

    Technical specifications

    Product typeMiniature circuit breaker (MCB)
    Manufacturer / seriesMerlin Gerin (Schneider Electric) / Multi9 C60 UL489
    Manufacturer code60139
    Number of poles2P (2 protected poles)
    Rated current In4 A (at 25 °C)
    Tripping curveC
    Magnetic tripping limit8.5 × In ±20 % (AC); 12 × In ±20 % (DC)
    Rated operational voltage Ue240 / 415 / 440 V AC; 125 V DC
    Frequency50/60 Hz
    Breaking capacityUL 489: 10 kA (240 V AC / 125 V DC); EN/IEC 60947-2: Icu 20 kA (240 V AC), 10 kA (415 V AC), 6 kA (440 V AC), 10 kA (125 V DC)
    Limitation class3 (EN/IEC 60947-2)
    Rated impulse withstand voltage Uimp6 kV
    Suitable for isolationYes (EN/IEC 60947-2)
    TerminalsTunnel terminals, top or bottom, 2.5–25 mm² (AWG 14–4), stripping length 14 mm, tightening torque 2.5 N·m
    Mounting35 mm DIN rail, clip-on
    Dimensions (W × H × D)36 × 107 × 73 mm
    Weight0.22 kg
    Degree of protectionIP20 (terminals); IP40 in modular enclosure
    Operating temperature−30…+70 °C
    Mechanical / electrical durability20,000 / 10,000 cycles
    Other featuresON/OFF position indication, padlockable
    StandardsUL 489, CSA C22.2 No 5, EN/IEC 60947-2
    Product statusDiscontinued by the manufacturer; Schneider recommended replacement – Multi9 C60BP / C60BPR

    Main functions

    • Overload protection – the thermal release disconnects the circuit before cables overheat.
    • Short-circuit protection – the C-curve magnetic release trips within milliseconds.
    • DC capable – up to 125 V DC, suitable for control and battery circuits.
    • Isolation function – suitable for safe isolation per EN/IEC 60947-2.
    • Padlocking – the lever can be locked during maintenance.
    • Original code – no changes to the diagram or equipment documentation.

    Where is it used?

    • Electrical cabinets of UL-certified US and Canadian machine tools, compressors and packaging lines
    • Control, signalling and PLC power circuits
    • DC circuits up to 125 V: 24–110 V DC control, battery systems
    • Protection of industrial power supplies and drive control sections
    • Replacing an original Merlin Gerin C60 breaker in a faulty panel without rework
    • Equipment repair where documentation specifies this exact code

    Use by need

    For maintenance technicians.
    You get the same code 60139 shown on the machine diagram – no substitute approval needed.
    For panel builders.
    The same Multi9 C60 housing fits existing busbars and DIN rail.
    For purchasing.
    Order this discontinued UL489 breaker together with other electrical items, with a VAT invoice for your company.

    Practical use

    If breaker 60139 in the cabinet of a US-made machine has tripped and will not reset, and the diagram specifies this exact code, you replace it with the same one – no rewiring, no substitute approval and no change to compliance documents.

    Advantages

    • Original Merlin Gerin / Schneider code
    • Certified to UL 489 and CSA C22.2 No 5
    • Works in AC and DC circuits (up to 125 V DC)
    • Suitable for isolation, padlockable
    • Wide operating temperature range: −30…+70 °C
    • Pickup available in Šiauliai

    Disadvantages / limitations

    • Discontinued – for new projects choose Multi9 C60BP / C60BPR or Acti9 iC60
    • Rated current calibrated at 25 °C (UL), not 30 °C as with European MCBs
    • Breaking capacity drops to 6 kA at 440 V AC
    • No residual current protection – a separate RCD is required

    Safety and installation notes

    • Installation and replacement only by a qualified electrician, with power off and absence of voltage verified.
    • Before replacing, compare the old breaker code, poles, current and curve – they must match.
    • Do not choose a higher current than the cable cross-section allows.
    • Check that the prospective short-circuit current does not exceed the breaker breaking capacity (6 kA (440 V AC)).
    • In DC circuits observe the polarity and voltage limit specified by the manufacturer.
    • Tighten terminals to the correct torque (2.5 N·m) – a loose terminal heats up.

    Quick selection guide

    2P
    4 A
    C curve
    AC/DC
    UL 489
    Multi9 C60
    Suitable when you need:
    • to replace a failed Merlin Gerin C60 breaker with the same code 60139;
    • a UL489-certified breaker for US or Canadian equipment;
    • 2P, 4 A, C-curve protection.
    Check before use:
    • the old breaker code and curve;
    • supply voltage and short-circuit current;
    • cable cross-section and terminal type.
    Important reminder: a circuit breaker does not replace a residual current device (RCD) or surge protector – these are separate protective devices.

    FAQ

    Is this an original Merlin Gerin breaker?
    Yes, it is a Merlin Gerin (Schneider Electric) Multi9 C60 UL489 series breaker, code 60139.
    How does it differ from the European C60N?
    It is certified to UL 489 and CSA, and its rated current is calibrated at 25 °C.
    Can it be used for DC?
    Yes, the manufacturer specifies up to 125 V DC.
    What replaces it if I need a current model?
    Schneider recommended replacement – Multi9 C60BP / C60BPR.
    Does it fit a standard DIN rail?
    Yes, it mounts on a 35 mm DIN rail.
    Can I pick it up in Šiauliai?
    Yes, you can collect it at our office, J. Basanavičiaus g. 23, Šiauliai.

    Miniature circuit breaker | 2P | 4A | C | AC/DC | UL489 | DIN | Merlin Gerin | Multi9 C60 | 60139

    Original Merlin Gerin Multi9 C60 UL489 circuit breaker 60139: 2P, 4 A, C curve, 240 / 415 / 440 V AC; 125 V DC. For electrical cabinets and control circuits of US and Canadian equipment, DIN rail mounting.

    Published: 2026-11-20 · Data verified against the manufacturer datasheet: 2026-11-20

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • privacy policy

    Information