Modular circuit breaker | 1P | 10A | C | 6kA | DIN | MCB | Eaton | PL6-C10/1 | 286531
Code: 286531Modular circuit breaker designed for protecting single-phase 230 V electrical circuits against overload and short circuits. This is a 1P, 10A, C-curve, 6 kA breaking capacity MCB-type circuit breaker, mountable on a DIN rail in electrical distribution boards. The model is suitable for protecting lighting, low-power circuits, control circuits, and other 230 V electrical installation lines where a 10 A rated current is required.-
Eaton modular circuit breaker – 1P, 10A, C-curve, 6kA, DIN
Modular circuit breaker, designed to protect single-phase 230 V electrical circuits against overload and short circuits. This is a 1P, 10A, C-curve, 6 kA breaking capacity MCB-type circuit breaker, mountable on a DIN rail in electrical distribution boards. The model is suitable for protecting lighting, low-power circuits, control circuits, and other 230 V electrical installation lines where a 10 A rated current is required.
Main idea:
This circuit breaker is used for single-phase electrical circuit protection. It automatically disconnects the circuit when current exceeds the permitted limit or a short circuit occurs. The C-curve allows the breaker to be used in circuits where moderate inrush currents may occur, such as lighting, small appliances, or control circuits.Poles
1PCurrent
10 ACharacteristic
CBreaking capacity
6 kAOperating principle
The modular circuit breaker protects the electrical circuit from two main risks: overload and short circuit. In the event of a prolonged excessive load, the thermal protection trips, and in the event of a short circuit, the electromagnetic release mechanism is triggered.
The 1P construction means the breaker disconnects one pole, typically the phase conductor. The C-curve is universal and frequently used in residential, commercial, and technical electrical installations where moderate device inrush currents are possible.
What does C-curve mean?
C-curve circuit breakers are typically used in circuits where a higher short-term current may appear during startup than in a standard resistive load. These breakers are often chosen for lighting, small motors, transformers, control, or general-purpose circuits, though the final selection must be made according to the project, load, and cable parameters.Technical parameters
Product type Modular circuit breaker / MCB Manufacturer Eaton Model PL6-C10/1 Product code 286531 Number of poles 1P Rated current 10 A Tripping characteristic C Rated switching/breaking capacity 6 kA according to IEC/EN 60898-1 Rated operating voltage Ue up to 230 V Rated insulation voltage Ui 440 V Rated impulse withstand voltage Uimp 4 kV Frequency range 50–60 Hz Mounting On DIN rail Standard IEC/EN 60898-1 Purpose Protection of electrical circuits against overload and short circuit Application area Electrical distribution boards, residential, commercial, and technical electrical installations Where is it used?
- Electrical distribution boards – for protecting individual 230 V circuits.
- Lighting circuits – when the project requires 10 A protection and C-curve.
- Control circuits – for automation, alarm, or auxiliary circuit protection, if parameters are appropriate.
- Residential spaces – for protecting electrical installations in apartments, houses, or summer homes.
- Commercial and technical areas – for low-power lines, device power supply, or auxiliary circuits.
Practical installation example
For example, an Eaton PL6-C10/1 circuit breaker is installed in an electrical distribution board on a DIN rail. It can protect a 230 V lighting circuit or another low-power circuit when the project specifies 10 A protection and a C-curve.
When an overload or short circuit occurs, the breaker disconnects the circuit and helps protect cables and equipment from potential damage. After the fault is cleared, the breaker can be reset manually.
Pros
- Eaton manufacturer – a renowned manufacturer of electrical equipment.
- 1P construction – a compact solution for protecting a single-phase circuit.
- 10 A rated current – suitable for many lighting and low-power circuits.
- C-curve – universal for most residential and technical installation circuits.
- 6 kA breaking capacity – suitable for many standard distribution boards, if aligned with the project.
- DIN rail mounting – easy installation in modular electrical boards.
- Overload and short circuit protection – helps protect the electrical circuit and cables.
Cons / limitations
- 1P only – disconnects one pole, so it is not suitable for all schemes as a full double-pole disconnection.
- 10 A current limit – not suitable for circuits requiring higher rated current.
- C-curve is not always suitable – some circuits may require B or D-curve.
- 6 kA must be verified against the network – breaking capacity must match the potential short-circuit current at the installation location.
- Does not replace RCD / RCBO protection – this MCB does not protect against leakage current, so additional earth leakage protection may be required for some circuits.
Safety and installation notes
A circuit breaker is an electrical protection device, so when selecting and installing it, it is necessary to assess the circuit load, cable cross-section, laying conditions, short-circuit current, earthing system, and compatibility with other protective devices.
- Installation must be performed by a qualified electrician in accordance with applicable electrical safety regulations.
- Before working, it is essential to disconnect the power supply and check that there is no voltage in the circuit.
- A 10 A breaker must be selected based on the cable and load – incorrect selection can lead to overheating or nuisance tripping.
- The 6 kA breaking capacity must be sufficient for the specific installation location.
- MCB does not protect against leakage current – an RCD or RCBO may be required for personal protection and specific circuits.
- C-curve must be chosen based on the load type and inrush currents.
Quick selection guide
Eaton PL6-C10/1 – a suitable choice when you need a 1-pole, 10 A, C-curve circuit breaker to protect a 230 V electrical circuit. It is mounted on a DIN rail and used in distribution boards as protection against overload and short circuit.
Poles
1PCurrent
10 ACharacteristic
CBreaking capacity
6 kASuitable when you need:- to protect a 230 V electrical circuit;
- to use a 10 A circuit breaker according to the project;
- to mount the device in a modular electrical board on a DIN rail;
- to use a C-curve MCB for circuits with moderate inrush currents;
- to protect the circuit against overload and short circuit.
Check before installation:- does the circuit require exactly 10 A rated current;
- does the C-curve suit the load type;
- are the cable cross-section and laying conditions compatible with 10 A protection;
- is the 6 kA breaking capacity sufficient for the installation location;
- is additional RCD or RCBO protection required.
Important reminder:
This circuit breaker is designed for overload and short circuit protection. It does not replace earth leakage protection, so an RCD or RCBO may be required for personal safety or specific circuits.FAQ – frequently asked questions
What is this circuit breaker for?
It is intended for 230 V electrical circuit protection against overload and short circuits.What is the rated current of this breaker?
The rated current is 10 A.What does C-curve mean?
C-curve means the breaker is adapted for circuits where moderate short-term inrush currents may occur. Final selection depends on the load type and electrical project.What is the breaking capacity?
The breaking capacity is 6 kA according to IEC/EN 60898-1.Is this breaker mounted on a DIN rail?
Yes, this is a modular circuit breaker designed for mounting on a DIN rail in an electrical board.Does this breaker protect against earth leakage?
No. This is an MCB circuit breaker protecting against overload and short circuits. For leakage current protection, an RCD or RCBO is required.Can it be used for lighting circuits?
Yes, it can be used if the project specifies a 10 A rated current, C-curve, and cable parameters suitable for the lighting circuit.Reliable 230 V circuit protection for Eaton electrical board
This circuit breaker provides a compact and clear solution for 230 V electrical circuit protection against overload and short circuits.
Due to its 1P construction, 10 A rated current, C-curve, 6 kA breaking capacity, and DIN rail mounting, this MCB is a practical choice for electrical distribution boards, lighting lines, control circuits, and other compatible 230 V installations.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerCircuit breakers, also known as protective breakers or circuit interrupters, are essential components of electrical protection systems. They automatically disconnect the electrical circuit when it becomes overloaded or when a short circuit occurs. They are used in electrical installations to protect equipment and people from electrical faults. Circuit breakers come in various types and have different characteristics depending on the installation location, circuit load, and other specifications.
Circuit Breaker Characteristics:
B, C, and D Characteristics:
B characteristic: Used in residential areas or low-load systems. They operate when the current exceeds the nominal current by 3 to 5 times.
C characteristic: Commonly used in both residential and commercial or industrial spaces. Their operating threshold is 5 to 10 times the nominal current, making them suitable for loads with high inrush currents (e.g., motors, lighting systems).
D characteristic: Used in industrial installations where loads have very high inrush currents (e.g., compressors, transformers). They operate when the current exceeds the nominal by 10 to 20 times.
Advantages (Pros) of Circuit Breakers:Safety: Circuit breakers ensure that the circuit is automatically disconnected in case of overload or short circuit, preventing wire burning, equipment damage, or even fires.
Reliability: They are highly reliable and can operate for long periods without maintenance, reacting automatically when electrical faults occur.
Ease of use: There is no need to replace the breaker after it trips. After an overload or short circuit, the circuit breaker can simply be reset to its operational position, avoiding the need to replace fuses.
Precision: Circuit breakers operate accurately according to the nominal current and circuit characteristics, ensuring minimal unnecessary power interruption.
Protection against short circuits and overloads: Breakers not only protect against short circuits but also against prolonged overloads, which can be harmful to electrical systems.
Versatility: There are various types of circuit breakers suitable for different systems, from small household installations to large industrial systems.
Easy reset: After a trip, the breaker can simply be reset without the need to replace it (unlike fuses that need to be replaced after a trip).
Disadvantages (Cons) of Circuit Breakers:High cost: Circuit breakers, especially those with more complex functions (e.g., adjustable protection limits), are more expensive than simple fuses.
Limited operating range: While breakers provide protection against overloads and short circuits, they cannot protect against all types of electrical faults, such as overvoltage. Additional protection devices are required for that.
Larger size: Circuit breakers are generally larger than fuses, meaning their installation may require more space in the distribution panel.
Limited protection against frequent overloads: If the electrical system experiences frequent overloads, circuit breakers may not fully protect equipment from long-term damage caused by continuous overload exposure.
More complex repair: Some complex circuit breakers may require more maintenance or repairs if they malfunction or trip incorrectly.
Applications of Circuit Breakers:Household Installations:
B characteristic breakers are most commonly used in residential installations to protect circuits from short circuits and overloads. They are suitable for lighting circuits, plugs, and other low-load devices.
C characteristic breakers are also used in homes but are better suited for areas with higher inrush currents, such as electric motors or heaters.
Commercial and Industrial Installations:C characteristic breakers are often used in commercial and industrial buildings. They are suitable for electrical equipment with medium inrush currents.
D characteristic breakers are used in industrial equipment where large inrush currents occur, such as for heavy motors, transformers, or high-power equipment protection.
Large Mechanisms and Industrial Equipment:D characteristic breakers are used where the inrush currents are very high. This includes electrical network distribution sections, industrial machinery, and transformers.
Protection of Electronics Equipment:Certain types of circuit breakers are used to protect electronic equipment, such as in server rooms or other sensitive systems where fast and precise protection is required.
Conclusion:
Circuit breakers are essential in modern electrical systems to ensure safe power supply and protection from faults. They have many advantages, such as reliability, safety, and easy resetting, but they also have some drawbacks, such as higher cost and larger size. Their selection depends on the intended use and required protection parameters.K – Trips when the current is 8-12 times higher than the nominal current, designed to protect circuits powering motors, capacitors, and transformers.
S – Trips when the current is 13-17 times higher than the nominal current, designed for the protection of control transformers.
Z – Trips when the current is 2-3 times higher than the nominal current, designed for the protection of computer equipment and other electronic components and devices.
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products