  • Modular circuit breaker | 3P | 6A | B | 10kA | DIN | MCB | Eaton xPole | PLSM-B6/3-MW

    Code: PLSM-B6/3-MW

    The Moeller PLSM-B6/3-MW modular circuit breaker is a reliable, professional protection device designed to safeguard three-phase electrical circuits against overloads and short circuits. It complies with the high standards of IEC/EN 60898-1 and features a 10 kA breaking capacity, making it suitable for both residential and industrial installations where safety and reliability are essential.

    The B-type tripping characteristic is ideal for protecting lighting circuits, household appliances, and electronic equipment. Its compact modular design allows for easy installation in standard distribution cabinets on DIN rails. 

  • Modular circuit breaker | 3P | 6A | B | 10kA | DIN | MCB | Eaton xPole | PLSM-B6/3-MW

    Eaton xPole PLSM-B6/3-MW – a three-phase modular circuit breaker with a 6 A rated current, B characteristic and 10 kA breaking capacity according to EN 60898-1. It protects the three-phase circuit cable against overload and short circuit.

    Key idea:
    All three poles trip together, so if one phase is lost or a fault occurs, a three-phase device is not left running on only some of the phases. The 10 kA capacity allows it to be used in both commercial and industrial panels.
    Rated current
    6 A, 3P
    Characteristic
    B (3–5 × In)
    Breaking capacity
    10 kA (EN 60898-1)
    Voltage
    400 V AC

    How it works

    The breaker is mounted on a 35 mm DIN rail, with all three phases connected to it. All poles are mechanically linked and trip simultaneously.

    The thermal element disconnects sustained overloads, while the electromagnetic element instantly disconnects a short circuit when the current reaches 3–5 times the rated value (B characteristic).

    Why choose the PLSM-B6/3?
    The B characteristic responds sensitively to faults in low-current three-phase circuits – control, metering and lighting – while the 10 kA capacity provides a margin in panels close to a transformer substation.

    Technical specifications

    Product typeModular circuit breaker (MCB)
    Manufacturer / seriesEaton (Moeller) xPole PLSM
    ModelPLSM-B6/3-MW
    Number of poles3P
    Rated current6 A
    Rated voltage400 V AC, 50/60 Hz
    CharacteristicB
    Breaking capacity10 kA (EN 60898-1)
    Mounting35 mm DIN rail, 3 modules
    Mechanical service lifeup to 20 000 cycles
    StandardsEN 60898-1

    Key functions

    • Three-phase protection – all phases are disconnected together.
    • Overload protection – the cable does not overheat under sustained load.
    • Short-circuit protection – instant tripping reduces the risk of damage.
    • B characteristic – sensitive tripping in low-current circuits.
    • 10 kA breaking capacity – suitable for locations with higher short-circuit current.

    Where is it used?

    • Three-phase control and automation circuits
    • Metering and signalling circuits
    • Three-phase lighting
    • Low-power three-phase equipment without high inrush currents
    • Commercial and industrial panels
    • Replacing old Eaton / Moeller breakers

    Use by need

    For the automation electrician.
    Protection of low-current three-phase circuits with a sensitive B characteristic.
    For the panel builder.
    A well-known manufacturer and 10 kA capacity – easier to meet project requirements.
    For the facility manager.
    Replace a faulty Eaton breaker with a product from the same series.

    Practical use

    If a three-phase control circuit supplies relay and contactor coils, the PLSM-B6/3 will sensitively disconnect a fault, and its 10 kA capacity allows it to be installed in the building's main distribution board as well.

    Pros

    • 10 kA breaking capacity
    • All poles trip together
    • Sensitive B characteristic
    • Well-known manufacturer Eaton (Moeller)
    • Standard DIN format

    Cons / limitations

    • The B characteristic is not suitable for motors with high inrush currents – choose C or D
    • Does not disconnect the neutral – choose 3P+N when required
    • Does not protect against residual current

    Safety and installation notes

    • Installation must be carried out only by a qualified electrician with the power disconnected.
    • The 6 A rated current must not exceed the cable's current-carrying capacity (In ≤ Iz).
    • Check that the short-circuit current does not exceed 10 kA.
    • Socket-outlet and damp-room circuits require a 30 mA residual current device.

    Quick selection guide

    3P | 6 A
    B | 10 kA
    400 V AC
    DIN | 3 modules
    Suitable when you need:
    • to protect a low-current three-phase circuit;
    • sensitive tripping in control circuits;
    • a breaking capacity higher than 6 kA.
    Check before use:
    • that the circuit has no high inrush currents;
    • that 6 A matches the cable;
    • that there is space for 3 modules in the panel.
    Important reminder: a circuit breaker protects the cable, but does not replace a residual current device (RCD).

    FAQ

    What is the difference between B and C characteristics?
    B trips at 3–5 × In, C at 5–10 × In; C is usually chosen for motors.
    Is it suitable for a motor?
    For a small motor without high inrush current – yes; otherwise choose C or D.
    What does “MW” in the code mean?
    It is part of Eaton's series designation; the key parameters are 3P, 6 A, B, 10 kA.
    Is 10 kA enough?
    For most commercial and industrial panels – yes.
    Does it disconnect the neutral?
    No – that requires a 3P+N or 4P breaker.
    Does it protect against electric shock?
    No – that requires a residual current device (RCD).

    Modular circuit breaker | 3P | 6A | B | 10kA | DIN | MCB | Eaton xPole | PLSM-B6/3-MW

    Eaton xPole PLSM-B6/3-MW – a 3P 6 A modular circuit breaker with B characteristic and 10 kA breaking capacity. Reliable protection of low-current three-phase circuits for commercial and industrial panels.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information