Modular circuit breaker | 3P | 6A | B | 10kA | DIN | MCB | Eaton xPole | PLSM-B6/3-MW
Code: PLSM-B6/3-MWPrice 93.98 € VAT incl.( 77.67 € VAT excl. )The Moeller PLSM-B6/3-MW modular circuit breaker is a reliable, professional protection device designed to safeguard three-phase electrical circuits against overloads and short circuits. It complies with the high standards of IEC/EN 60898-1 and features a 10 kA breaking capacity, making it suitable for both residential and industrial installations where safety and reliability are essential.
The B-type tripping characteristic is ideal for protecting lighting circuits, household appliances, and electronic equipment. Its compact modular design allows for easy installation in standard distribution cabinets on DIN rails.
-
Modular circuit breaker | 3P | 6A | B | 10kA | DIN | MCB | Eaton xPole | PLSM-B6/3-MW
Eaton xPole PLSM-B6/3-MW – a three-phase modular circuit breaker with a 6 A rated current, B characteristic and 10 kA breaking capacity according to EN 60898-1. It protects the three-phase circuit cable against overload and short circuit.
Key idea:
All three poles trip together, so if one phase is lost or a fault occurs, a three-phase device is not left running on only some of the phases. The 10 kA capacity allows it to be used in both commercial and industrial panels.Rated current
6 A, 3PCharacteristic
B (3–5 × In)Breaking capacity
10 kA (EN 60898-1)Voltage
400 V ACHow it works
The breaker is mounted on a 35 mm DIN rail, with all three phases connected to it. All poles are mechanically linked and trip simultaneously.
The thermal element disconnects sustained overloads, while the electromagnetic element instantly disconnects a short circuit when the current reaches 3–5 times the rated value (B characteristic).
Why choose the PLSM-B6/3?
The B characteristic responds sensitively to faults in low-current three-phase circuits – control, metering and lighting – while the 10 kA capacity provides a margin in panels close to a transformer substation.Technical specifications
Product type Modular circuit breaker (MCB) Manufacturer / series Eaton (Moeller) xPole PLSM Model PLSM-B6/3-MW Number of poles 3P Rated current 6 A Rated voltage 400 V AC, 50/60 Hz Characteristic B Breaking capacity 10 kA (EN 60898-1) Mounting 35 mm DIN rail, 3 modules Mechanical service life up to 20 000 cycles Standards EN 60898-1 Key functions
- Three-phase protection – all phases are disconnected together.
- Overload protection – the cable does not overheat under sustained load.
- Short-circuit protection – instant tripping reduces the risk of damage.
- B characteristic – sensitive tripping in low-current circuits.
- 10 kA breaking capacity – suitable for locations with higher short-circuit current.
Where is it used?
- Three-phase control and automation circuits
- Metering and signalling circuits
- Three-phase lighting
- Low-power three-phase equipment without high inrush currents
- Commercial and industrial panels
- Replacing old Eaton / Moeller breakers
Use by need
For the automation electrician.
Protection of low-current three-phase circuits with a sensitive B characteristic.For the panel builder.
A well-known manufacturer and 10 kA capacity – easier to meet project requirements.For the facility manager.
Replace a faulty Eaton breaker with a product from the same series.Practical use
If a three-phase control circuit supplies relay and contactor coils, the PLSM-B6/3 will sensitively disconnect a fault, and its 10 kA capacity allows it to be installed in the building's main distribution board as well.Pros
- 10 kA breaking capacity
- All poles trip together
- Sensitive B characteristic
- Well-known manufacturer Eaton (Moeller)
- Standard DIN format
Cons / limitations
- The B characteristic is not suitable for motors with high inrush currents – choose C or D
- Does not disconnect the neutral – choose 3P+N when required
- Does not protect against residual current
Safety and installation notes
- Installation must be carried out only by a qualified electrician with the power disconnected.
- The 6 A rated current must not exceed the cable's current-carrying capacity (In ≤ Iz).
- Check that the short-circuit current does not exceed 10 kA.
- Socket-outlet and damp-room circuits require a 30 mA residual current device.
Quick selection guide
3P | 6 AB | 10 kA400 V ACDIN | 3 modulesSuitable when you need:- to protect a low-current three-phase circuit;
- sensitive tripping in control circuits;
- a breaking capacity higher than 6 kA.
Check before use:- that the circuit has no high inrush currents;
- that 6 A matches the cable;
- that there is space for 3 modules in the panel.
Important reminder: a circuit breaker protects the cable, but does not replace a residual current device (RCD).FAQ
What is the difference between B and C characteristics?
B trips at 3–5 × In, C at 5–10 × In; C is usually chosen for motors.Is it suitable for a motor?
For a small motor without high inrush current – yes; otherwise choose C or D.What does “MW” in the code mean?
It is part of Eaton's series designation; the key parameters are 3P, 6 A, B, 10 kA.Is 10 kA enough?
For most commercial and industrial panels – yes.Does it disconnect the neutral?
No – that requires a 3P+N or 4P breaker.Does it protect against electric shock?
No – that requires a residual current device (RCD).Modular circuit breaker | 3P | 6A | B | 10kA | DIN | MCB | Eaton xPole | PLSM-B6/3-MW
Eaton xPole PLSM-B6/3-MW – a 3P 6 A modular circuit breaker with B characteristic and 10 kA breaking capacity. Reliable protection of low-current three-phase circuits for commercial and industrial panels.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Circuit breakers, also known as protective breakers or circuit interrupters, are essential components of electrical protection systems. They automatically disconnect the electrical circuit when it becomes overloaded or when a short circuit occurs. They are used in electrical installations to protect equipment and people from electrical faults. Circuit breakers come in various types and have different characteristics depending on the installation location, circuit load, and other specifications.
Circuit Breaker Characteristics:
B, C, and D Characteristics:
B characteristic: Used in residential areas or low-load systems. They operate when the current exceeds the nominal current by 3 to 5 times.
C characteristic: Commonly used in both residential and commercial or industrial spaces. Their operating threshold is 5 to 10 times the nominal current, making them suitable for loads with high inrush currents (e.g., motors, lighting systems).
D characteristic: Used in industrial installations where loads have very high inrush currents (e.g., compressors, transformers). They operate when the current exceeds the nominal by 10 to 20 times.
Advantages (Pros) of Circuit Breakers:Safety: Circuit breakers ensure that the circuit is automatically disconnected in case of overload or short circuit, preventing wire burning, equipment damage, or even fires.
Reliability: They are highly reliable and can operate for long periods without maintenance, reacting automatically when electrical faults occur.
Ease of use: There is no need to replace the breaker after it trips. After an overload or short circuit, the circuit breaker can simply be reset to its operational position, avoiding the need to replace fuses.
Precision: Circuit breakers operate accurately according to the nominal current and circuit characteristics, ensuring minimal unnecessary power interruption.
Protection against short circuits and overloads: Breakers not only protect against short circuits but also against prolonged overloads, which can be harmful to electrical systems.
Versatility: There are various types of circuit breakers suitable for different systems, from small household installations to large industrial systems.
Easy reset: After a trip, the breaker can simply be reset without the need to replace it (unlike fuses that need to be replaced after a trip).
Disadvantages (Cons) of Circuit Breakers:High cost: Circuit breakers, especially those with more complex functions (e.g., adjustable protection limits), are more expensive than simple fuses.
Limited operating range: While breakers provide protection against overloads and short circuits, they cannot protect against all types of electrical faults, such as overvoltage. Additional protection devices are required for that.
Larger size: Circuit breakers are generally larger than fuses, meaning their installation may require more space in the distribution panel.
Limited protection against frequent overloads: If the electrical system experiences frequent overloads, circuit breakers may not fully protect equipment from long-term damage caused by continuous overload exposure.
More complex repair: Some complex circuit breakers may require more maintenance or repairs if they malfunction or trip incorrectly.
Applications of Circuit Breakers:Household Installations:
B characteristic breakers are most commonly used in residential installations to protect circuits from short circuits and overloads. They are suitable for lighting circuits, plugs, and other low-load devices.
C characteristic breakers are also used in homes but are better suited for areas with higher inrush currents, such as electric motors or heaters.
Commercial and Industrial Installations:C characteristic breakers are often used in commercial and industrial buildings. They are suitable for electrical equipment with medium inrush currents.
D characteristic breakers are used in industrial equipment where large inrush currents occur, such as for heavy motors, transformers, or high-power equipment protection.
Large Mechanisms and Industrial Equipment:D characteristic breakers are used where the inrush currents are very high. This includes electrical network distribution sections, industrial machinery, and transformers.
Protection of Electronics Equipment:Certain types of circuit breakers are used to protect electronic equipment, such as in server rooms or other sensitive systems where fast and precise protection is required.
Conclusion:
Circuit breakers are essential in modern electrical systems to ensure safe power supply and protection from faults. They have many advantages, such as reliability, safety, and easy resetting, but they also have some drawbacks, such as higher cost and larger size. Their selection depends on the intended use and required protection parameters.K – Trips when the current is 8-12 times higher than the nominal current, designed to protect circuits powering motors, capacitors, and transformers.
S – Trips when the current is 13-17 times higher than the nominal current, designed for the protection of control transformers.
Z – Trips when the current is 2-3 times higher than the nominal current, designed for the protection of computer equipment and other electronic components and devices.
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products










