Modular circuit breaker with residual current device | 2P | 16A | B | 10kA | 0.03A | type AC | DIN | ECO FAP10-AC | Promfactor Baltic | FAP10B16030AC
Code: FAP10B16030ACPrice 22.77 € VAT incl.( 18.82 € VAT excl. )-
Modular circuit breaker with residual current device | 2P | 16A | B | 10kA | 0.03A | type AC | DIN | ECO FAP10-AC | Promfactor Baltic | FAP10B16030AC
FAP10B16030AC – Promfactor Baltic ECO FAP10-AC series circuit breaker with residual current protection (RCBO): 2P (1P+N), curve B 16 A, residual current 30 mA, type AC, breaking capacity 10 kA. Overload, short-circuit and residual current protection in one device – for one single-phase ~230 V circuit where each circuit needs its own residual current protection.
Key idea:
The RCBO protects the 16 A circuit cable against overload and short circuit, and the 30 mA residual module protects people against electric shock. Type AC responds to sinusoidal AC leakage currents – suitable for lighting, heating and ordinary socket circuits. In case of leakage only this circuit trips, the others keep working.Rated current / curve
B16 (16 A)Residual current
30 mA (0.03 A), type ACBreaking capacity
10 kAPoles / voltage
2P (1P+N) / ~230 VOperating principle
The breaker is mounted in the panel on a DIN rail and connected to one single-phase circuit: phase and neutral pass through the device, the PE conductor does not.
The thermal release responds to sustained overload above 16 A, the electromagnetic release to short-circuit current according to curve B (B – 3–5 In, for circuits with low inrush currents). The residual module compares phase and neutral currents and disconnects both poles at 30 mA.
Result – each circuit has its own residual current protection: a fault in one circuit does not switch off the whole house or apartment, and the fault is easier to locate.
Why choose FAP10B16030AC?
One modular device instead of a separate circuit breaker and RCD – a clearer panel layout and selective residual current protection for each circuit; breaking capacity 10 kA.Technical specifications
Product type Circuit breaker with residual current protection (RCBO) Manufacturer / code Promfactor Baltic / FAP10B16030AC Series ECO FAP10-AC Number of poles 2P (1P+N) Rated current (In) 16 A Tripping curve B Rated residual current (IΔn) 30 mA (0.03 A) Residual current type AC Ultimate breaking capacity (Icu) 10 kA (10 000 A) Residual module type Electromechanical Rated voltage (Ue) ~230 V Frequency 50/60 Hz Insulation voltage (Ui) 500 V Impulse withstand voltage (Uimp) 4000 V Selectivity class 3 Fast tripping time ≤0.1 s Electrical / mechanical endurance 6000 / 20 000 cycles Terminals cable up to 25 mm²; tightening torque 3.5 Nm Mounting 35 × 7.5 mm DIN rail Degree of protection IP20 Operating temperature -25…+55 °C Storage temperature -25…+70 °C Standard IEC 61009 Main functions
- Overload protection – the 16 A circuit cable does not overheat.
- Short-circuit protection B – more sensitive tripping for circuits with low inrush currents.
- Residual current protection 30 mA – additional protection of people against electric shock.
- Type AC – detects sinusoidal AC leakage currents.
- Breaking capacity 10 kA – also suitable for sites with higher prospective short-circuit current.
- Separate protection for each circuit – in case of leakage only one circuit trips.
Where is it used?
- Apartment and house panels with per-circuit residual current protection
- Socket circuits
- Bathroom and wet room circuits
- Kitchen appliance circuits
- Outdoor sockets and lighting
- Office workstation circuits
- Panel upgrades where there is no space for a separate RCD
Use by need
For the apartment or house owner.
A fault in one circuit does not switch off the whole home – lighting and other appliances stay on.For the installing electrician.
One device instead of two – faster installation and fewer connections in the panel.For the designer.
The ECO FAP10-AC series offers curves B and C – easy to match to the load.Practical application
If in an apartment the kitchen sockets are supplied by a separate 16 A circuit and a leakage there should not switch off the whole apartment, protect this circuit with FAP10B16030AC: overload, short circuit and 30 mA leakage will disconnect only the kitchen sockets.Advantages
- Overload, short-circuit and residual current protection in one device
- 30 mA additional protection of people
- Breaking capacity 10 kA
- Curve B 16 A
- Selective protection – only one circuit trips
- "T" button for periodic testing
Disadvantages / limitations
- Type AC is not suitable for circuits with inverters, frequency converters or EV charging
- Intended for single-phase circuits only
- More expensive than one shared RCD for several breakers
- Curve and current must match the cable cross-section
Safety and installation notes
- Installation by a qualified electrician after disconnecting the supply and verifying absence of voltage
- The circuit cable cross-section must match 16 A protection
- Connect phase and neutral according to the device marking; do not route PE through it
- Do not interconnect the neutrals of different RCBOs
- Check that the prospective short-circuit current does not exceed 10 kA
- After installation, test with the "T" button and an RCD tester
Quick selection guide
2P (1P+N)B1630 mAtype AC10 kA~230 VSuitable when you need:- separate residual current protection for one circuit
- protection of a 16 A circuit
- overload, short-circuit and residual current protection in one device
Check before use:- whether the cable suits 16 A protection
- whether curve B suits the load
- whether type AC suits the connected equipment
- whether the prospective short-circuit current is ≤ 10 kA
Important reminder: An RCBO does not replace protective earthing or periodic inspection of the electrical installation.FAQ
Does FAP10B16030AC protect against short circuit?
Yes – it contains a curve B circuit breaker and 30 mA residual current protection.What is the difference between curves B and C?
B trips at 3–5 In, C at 5–10 In; C suits higher inrush currents.Is it suitable for inverters or frequency converters?
No – choose type A, F or B for such circuits.How many modules does it take?
It takes 2 modules on the DIN rail.Can it protect several circuits?
One circuit per RCBO is recommended – that keeps selectivity.How often should the "T" button be pressed?
Periodically, for example every few months, and after work in the panel.Modular circuit breaker with residual current device | 2P | 16A | B | 10kA | 0.03A | type AC | DIN | ECO FAP10-AC | Promfactor Baltic | FAP10B16030AC
Promfactor Baltic FAP10B16030AC – circuit breaker with residual current protection ECO FAP10-AC 2P B16 30 mA type AC, 10 kA, DIN – protection of a single-phase circuit against overload, short circuit and residual currents.
Published: 2026-11-07 · Data verified against the manufacturer's datasheet: 2026-11-06
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThe IP protection class indicates the device's resistance to environmental factors.

The first digit indicates protection against dust and solid objects.
The second digit indicates protection against moisture.First digit values:
X — Untested;
0 — No protection;
1 — Protected against solid objects larger than 50 mm;
2 — Protected against solid objects larger than 12.5 mm;
3 — Protected against solid objects larger than 1 mm;
4 — Protected against solid objects larger than 1 mm;
5 — Dust protected;
6 — Totally dustproof.
Second digit values:X — Untested;
0 — No protection;
1 — Protected against vertically falling water drops;
2 — Protected against water drops falling at a 15º angle;
3 — Protected against rain falling at a 60º angle;
4 — Protected against water splashes;
5 — Protected against water jets;
6 — Protected against large amounts of water;
7 — Protected against short-term immersion in water up to 1 meter deep;
8 — Protected against long-term immersion in water up to 3 meters deep.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products