Single-phase voltage relay | 1F | 50 A (max. 60 A) | U> 210–270 V | U< 120–200 V | white display | DIN | DigiTOP | VP-50A G3W
Code: VP-50A G3WPrice 60.93 € VAT incl.( 50.36 € VAT excl. )The DigiTOP VP-50A G3W is a single-phase digital voltage relay for DIN-rail mounting in a distribution board.
-
Single-phase voltage relay | 1F | 50 A (max. 60 A) | U> 210–270 V | U< 120–200 V | white display | DIN | DigiTOP | VP-50A G3W
The DigiTOP VP-50A G3W is a single-phase digital voltage relay for DIN-rail mounting in a distribution board. The full load current passes through its contact (50 A (briefly up to 60 A)), so it protects a whole apartment, a house circuit or a single appliance. When the voltage leaves the set limits, the relay disconnects the load and reconnects it after the set delay once the voltage is back to normal.
Key point:
The most common cause of damage to expensive appliances is a broken neutral in a three-phase supply or a sustained over- or undervoltage. The VP-50A G3W disconnects such voltage within hundredths of a second, before boiler electronics, a fridge or a TV are harmed, and its digital display always shows the actual mains voltage.Load current
50 A (max. 60 A)Voltage limits
U> 210–270 V, U< 120–200 VSwitch-on delay
5–600 sWidth
2 DIN modulesHow it works
The relay is installed in the board after the main circuit breaker: phase and neutral to the input, the protected load to the output. A microcontroller continuously measures the mains voltage and shows it on the display.
If the voltage rises above the upper limit (210–270 V) or drops below the lower limit (120–200 V), the relay disconnects the load: above the upper limit within hundredths of a second, at 120–170 V within up to 1 s, below 120 V instantly.
When the voltage returns to normal, the load is reconnected after the set delay (5–600 s). For fridges, heat pumps and air conditioners the manufacturer recommends a delay of at least 300 s.
Why choose the VP-50A G3W?
It protects all appliances connected after it from a broken neutral, overvoltage and undervoltage, and the display always shows the actual mains voltage.Technical specifications
Product type Single-phase digital voltage relay (power type) Manufacturer / model DigiTOP / VP-50A G3W (G3 – third generation) Network 1F, 230 V AC Rated load current 50 A Maximum load current 60 A Rated power (resistive load) 11 kW Measured voltage 50–400 V Upper limit U> 210–270 V (factory 250 V) Lower limit U< 120–200 V (factory 170 V) Trip time below the limit up to 1 s (120–170 V), instantly below 120 V Switch-on delay 5–600 s, 5 s step (factory 15 s) Voltage measurement error up to 1 % Display LED, white Overheating protection disconnects the load at 70 °C, reconnects after cooling to 60 °C Frequency mode 50 Hz (household mains) or Auto (generators), 45–65 Hz Own consumption up to 1.5 W Maximum wire cross-section 16 mm² Terminal tightening torque 2.2 ± 0.2 Nm Width 2 DIN modules of 17.5 mm Dimensions 90 × 35 × 67 mm Mounting 35 mm DIN rail Operating temperature −25…+50 °C Degree of protection IP20 (in damp locations only in a sealed enclosure) Service life 10 years Manufacturer warranty 5 years Main functions
- Overvoltage protection – with a broken neutral or a network fault, appliances are disconnected before their power supplies burn out.
- Undervoltage protection – compressors and pumps do not run at a voltage at which motors overheat.
- Adjustable switch-on delay 5–600 s – the compressor starts only after pressure has equalised, equipment does not cycle during an unstable supply.
- Digital voltage display – you see immediately whether the problem is in the grid or in the house.
- Overheating protection – at 70 °C inside the relay the load is disconnected and “Hot” is shown.
- Last trip memory – you can check at what voltage it disconnected; settings are kept during a power cut.
- Generator operation – Auto frequency mode and adjustable disconnect delay for an unstable source.
- Button lock – settings cannot be changed accidentally by others.
Where is it used?
- Apartment and house supplies (after the main circuit breaker)
- Electronics of gas and solid-fuel boilers and heat pumps
- Fridges, freezers, air conditioners
- Country houses and homes with a weak or long overhead line
- Rental properties and unattended sites
- Offices, server and security system supplies
- Generator-supplied circuits
Use by need
For the home or apartment owner.
One device protects all appliances against a broken neutral and voltage surges.For the electrician.
Simple installation after the main circuit breaker; limits and delay are set with buttons in a few minutes.For the country house owner.
On a weak network the display shows the real voltage, and equipment does not cycle needlessly.Practical use
A house has a three-phase supply with single-phase equipment distributed among the phases. If the neutral contact in the board burns out, the voltage on one phase rises to 300–380 V. The VP-50A G3W disconnects the load before the boiler controller and power supplies burn out, and after the neutral is restored the equipment is switched on after the set delay. In a three-phase house such a relay is installed for each phase supplying single-phase equipment, or a three-phase voltage relay is used instead.Pros
- Full load through the relay – no additional contactor needed
- Fast disconnection above the upper limit
- Adjustable limits and switch-on delay
- Digital voltage display
- Compact DIN housing
- Internal overheating protection
- Manufacturer warranty 5 years
Cons / limitations
- Does not protect against lightning and short surges – an SPD is needed
- Does not replace a circuit breaker or residual current device (RCD)
- Single-phase – a three-phase house needs a relay per phase or a three-phase relay
- IP20 – dry board only
- Does not measure current – for load limiting choose the VA series
Safety and installation notes
- Install only after disconnecting the supply and checking that no voltage is present; work must be done by a qualified electrician.
- A circuit breaker with a rated current not higher than the relay's rated current must be installed upstream.
- Use ferrules for stranded wires and tighten terminals to the torque specified by the manufacturer.
- Do not swap phase and neutral – otherwise the phase remains connected to the equipment when the relay trips.
- Install the surge protective device (SPD) before the relay, closer to the supply point.
- Do not install in damp, vibrating or explosive environments.
Quick selection guide
1F | 230 V50 A | max. 60 AU> 210–270 VU< 120–200 Vdelay 5–600 sSuitable when you need:- to protect an apartment, house or circuit against a broken neutral
- to protect a boiler, fridge or heat pump
- to see the mains voltage in the board
Check before use:- main circuit breaker current ≤ 50 A
- whether a surge protective device (SPD) is installed
- set a delay of ≥ 300 s for compressors
Important reminder: a voltage relay does not replace a surge protective device, a circuit breaker or an RCD – each protects against a different hazard.FAQ
Does the relay protect against lightning?
No – a lightning impulse lasts microseconds; a surge protective device (SPD) protects against it.Which relay should I choose for my circuit breaker?
The relay's rated current must be at least the current of the upstream circuit breaker – the VP-50A G3W suits a breaker up to 50 A.What switch-on delay should I set?
For fridges and compressors at least 300 s; 15–30 s is enough for lighting and electronics.Why does the relay trip often?
Most likely the limits are too narrow for a weak network – measure the mains voltage first and only then adjust the limits.Can it be installed in a three-phase house?
Yes – a single-phase relay is installed on each phase supplying the protected equipment.Does the relay replace an RCD?
No – only a residual current device (RCD) protects people from electric shock.Single-phase voltage relay | 1F | 50 A (max. 60 A) | U> 210–270 V | U< 120–200 V | white display | DIN | DigiTOP | VP-50A G3W
Single-phase voltage relay DigiTOP VP-50A G3W – protection against a broken neutral, overvoltage and undervoltage for an apartment, house or single circuit, with a digital voltage display.
Published: 2026-11-13 · Data verified against the manufacturer's manual: 2026-11-13
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Non-perforated DIN rail | profile | for mounting modular equipment in a distribution board | 35x7mm | 1m | BAKS | EURO | SZB35H 7/1 | 0613310Code: 0613310BAKS EURO SZB35H 7/1 – a non-perforated steel DIN rail designed for mounting modular electrical and automation equipment in distribution boards and control cabinets. Profile dimensions – 35 × 7 mm, steel thickness – 1.0 mm, length – 1000 mm (1 m). The solid non-perforated base allows mounting points to be selected according to the specific construction; the price is indicated per 1 metre.
Price 0.88 € VAT incl.( 0.73 € VAT excl. )Perforated DIN rail | profile for modular equipment mounting in a distribution cabinet | 35x7.5mm | 15cmCode: DR750150A perforated DIN rail is a mounting profile designed for quick and reliable installation of modular electrical equipment, such as circuit breakers, residual current relays, power supplies, or automation components, in distribution panels.
Thanks to the perforations, the rail can be easily mounted with screws directly onto the panel base, ensuring a firm and stable hold of the structure even under vibration or heavier loads.Price 0.52 € VAT incl.( 0.43 € VAT excl. )