  • Modular residual current circuit breaker (RCCB) | 4P | 63A | 0.03A | type AC | DIN | RCCB | Vecas | SGPL4633

    Code: SGPL4633

    Vecas AC type residual current circuit breaker is designed to protect people and electrical equipment from current leakage to the ground. It is one of the most important safety components in an electrical installation – the device automatically disconnects the power supply when a hazardous leakage is detected. This model is suitable for use in single-phase systems and is mounted on a standard 35mm DIN rail. 

  • Modular residual current circuit breaker (RCCB) | 4P | 63A | 0.03A | type AC | DIN | RCCB | Vecas | SGPL4633

    Vecas residual current circuit breaker (RCCB) 4P, 63 A, 30 mA, type AC. It monitors the current balance in the phase and neutral conductors and disconnects the circuit when part of the current leaks to earth.

    Key idea:
    The RCCB protects a three-phase 63 A circuit against residual currents – the 30 mA threshold is intended to protect people against electric shock. It does not interrupt overload or short circuit, so it is always used together with a circuit breaker.
    Poles
    4P
    Rated current
    63 A
    Residual current
    30 mA
    Residual current type
    AC

    Operating principle

    The RCCB is mounted on a 35 mm DIN rail in the board, downstream of a circuit breaker. All phase conductors and the neutral pass through it.

    In a healthy circuit the outgoing and returning currents are equal. If damaged insulation or contact causes part of the current to leak to earth, a difference appears. When it reaches the threshold (IΔn 30 mA), the RCCB disconnects the circuit.

    Result – reduced risk of electric shock and of fire caused by insulation faults. The RCCB does not interrupt overload or short-circuit currents – a circuit breaker is required for that.

    Why choose SGPL4633?
    One RCCB gives 30 mA residual current protection to all circuits connected downstream – a basic safety element of every apartment or house board.

    Technical specifications

    Product type Residual current circuit breaker (RCCB)
    Manufacturer / code Vecas / SGPL4633
    Series —
    Number of poles 4P
    Rated current (In) 63 A
    Rated residual current (IΔn) 30 mA (0,03 A)
    Residual current type AC
    Mounting 35 mm DIN rail

    Main functions

    • Residual current monitoring – disconnects the circuit when leakage reaches 30 mA
    • Protection against electric shock – the 30 mA threshold is intended for personal protection
    • Reduced fire risk – responds to leakage caused by insulation faults
    • Test button – lets you check periodically that the RCCB works
    • Manual operation – the toggle disconnects the circuit for maintenance

    Where is it used?

    • Three-phase house and farmstead boards
    • Workshops with three-phase equipment
    • Farm buildings
    • Commercial premises
    • Outdoor three-phase socket circuit
    • Distribution boards in production premises

    Use by need

    Electrician.
    Install 30 mA residual current protection in line with installation requirements.
    House or apartment owner.
    Protect the family against the risk of electric shock.
    Workshop or farm owner.
    Protect a three-phase circuit against residual currents.

    Practical application

    If a three-phase house needs 30 mA protection for socket circuits downstream of the main circuit breaker, this 4P RCCB is installed ahead of the circuit breakers – its 63 A rating must not be lower than that of the main breaker.

    Advantages

    • 30 mA residual current protection for people
    • One RCCB protects the whole three-phase circuit
    • Standard DIN rail mounting
    • Competitive price
    • Suitable for new and upgraded boards

    Disadvantages / limitations

    • Does not protect against overload or short circuit – a circuit breaker is required
    • Type AC is not suitable for circuits with pulsating DC residual current (inverters, induction hobs, some washing machines) – choose type A there
    • A 30 mA RCCB is not suitable as selective incoming protection – 100–300 mA or S-type devices are used for that
    • The manufacturer’s datasheet is not available – IP rating, temperature and terminal data are not stated

    Safety and installation notes

    • Install only with the voltage disconnected and its absence verified.
    • Work must be carried out by a qualified electrician.
    • Install a circuit breaker rated no higher than 63 A upstream of the RCCB.
    • Do not connect the neutral downstream of the device to the neutral of other circuits or to PE – otherwise it will trip unnecessarily.
    • After installation press the test button “T” and check that it trips.

    Quick selection guide

    4P
    63 A
    30 mA
    AC
    DIN 35 mm
    Suitable when you need:
    • 30 mA residual current protection for a three-phase 63 A circuit
    • protection of people against electric shock
    • a new or upgraded board
    Check before use:
    • Whether the circuit has equipment that requires type A protection
    • Whether there is an upstream circuit breaker rated no higher than 63 A
    • Whether there is enough space on the DIN rail
    Important reminder: An RCCB does not replace a circuit breaker – it does not protect against overload or short circuit.

    FAQ

    Does this RCCB protect against short circuit?
    No – a circuit breaker is required upstream.
    What is the 30 mA residual current for?
    The 30 mA threshold is used for protecting people against electric shock.
    Which residual current type is it?
    Type AC – responds to alternating residual current; for circuits with inverters choose type A.
    What does 63 A mean?
    It is the highest continuous current the RCCB can carry – the upstream circuit breaker must not be rated higher.
    Is it suitable for a three-phase installation?
    Yes – the 4P RCCB is intended for a three-phase circuit with neutral.
    How do I check that the RCCB works?
    Press the test button “T” – a working RCCB must trip.

    Modular residual current circuit breaker (RCCB) | 4P | 63A | 0.03A | type AC | DIN | RCCB | Vecas | SGPL4633

    Vecas SGPL4633 – 4P 63 A 30 mA type AC residual current circuit breaker for residual current protection of a three-phase circuit.

    Published: 2026-11-15 · Manufacturer’s datasheet not available – product marking parameters are stated

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information