Products catalog

  • Modular residual current circuit breaker with overcurrent protection (RCBO) | 2P | 63A | C | 6kA | 0.03A | DIN | RCBO | Vecas | RCBO2P633

    Code: RCBO2P633

    A combined residual current circuit breaker with overload and short-circuit protection (RCBO), designed to ensure both human safety against electric shock and the protection of wiring and equipment against electrical faults. Operating according to the IEC61009-1 standard, this device combines the functions of a circuit breaker and residual current relay in a single enclosure. It is a compact, efficient, and reliable solution for single-phase 230–240 V electrical systems.

  • Modular residual current circuit breaker with overcurrent protection (RCBO) | 2P | 63A | C | 6kA | 0.03A | DIN | RCBO | Vecas | RCBO2P633

    Vecas residual current circuit breaker with overcurrent protection (RCBO) 2P, C63, 30 mA, breaking capacity 6 kA. One device protects a single circuit against overload, short circuit and residual current.

    Key idea:
    One device protects one circuit against overload, short circuit and leakage at once, so a fault in one circuit does not switch off the whole board. Suitable for apartment, house and commercial boards where each circuit needs its own 30 mA protection.
    Poles
    2P
    Rated current
    C63 (63 A)
    Residual current
    30 mA
    Breaking capacity
    6 kA

    Operating principle

    The device is mounted on a 35 mm DIN rail and connected into a single circuit – phase and neutral pass through it.

    The circuit breaker part disconnects the circuit on overload or short circuit according to the C characteristic. The residual current part compares the phase and neutral currents and trips when the difference reaches 30 mA.

    Result – the circuit cable is protected against overheating and short circuit, people against residual current, while the other circuits stay on.

    Why choose RCBO2P633?
    Instead of a separate circuit breaker and RCCB – one device per circuit: less space in the board, and a leak does not switch off the other circuits.

    Technical specifications

    Product type Residual current circuit breaker with overcurrent protection (RCBO)
    Manufacturer / code Vecas / RCBO2P633
    Series —
    Number of poles 2P
    Rated current (In) 63 A
    Tripping characteristic C
    Rated residual current (IΔn) 30 mA (0,03 A)
    Rated breaking capacity (Icn) 6 kA
    Residual current type not stated
    Mounting 35 mm DIN rail

    Main functions

    • Overload protection – the circuit cable does not overheat when 63 A is exceeded for a long time
    • Short-circuit protection – the C characteristic quickly disconnects short-circuit current
    • Residual current monitoring – disconnects the circuit when leakage reaches 30 mA
    • Circuit-by-circuit selectivity – leakage in one circuit does not switch off the others
    • Test button – lets you check that the residual current part works

    Where is it used?

    • Bathroom socket circuit
    • Kitchen socket circuit
    • Outdoor sockets and garden equipment
    • Washing machine or water heater circuit
    • Office and shop circuits
    • House and country house boards

    Use by need

    Electrician.
    Fit each circuit with separate residual current and overcurrent protection in one device.
    Apartment owner.
    Protect the bathroom or kitchen circuit so that a leak does not switch off the whole apartment.
    Commercial premises manager.
    Avoid the whole board tripping because of one faulty circuit.

    Practical application

    If the bathroom socket circuit in an apartment is protected by a C63 circuit breaker and the cable is rated for it, it can be replaced with this RCBO – the circuit gains 30 mA residual current protection, and in case of leakage the other circuits stay on.

    Advantages

    • Overload, short-circuit and residual current protection in one device
    • Leakage in one circuit does not switch off the others
    • Breaking capacity 6 kA
    • Standard DIN rail mounting
    • Takes less space than a separate breaker and RCCB

    Disadvantages / limitations

    • Residual current type (AC or A) is not stated in this description – check the marking on the housing
    • Protects only one circuit – several circuits need several devices
    • The manufacturer’s datasheet is not available – IP rating, temperature and terminal data are not stated

    Safety and installation notes

    • Install only with the voltage disconnected and its absence verified.
    • Work must be carried out by a qualified electrician.
    • The circuit cable cross-section must match the 63 A protection.
    • Do not connect the neutral downstream of the device to the neutral of other circuits or to PE – otherwise it will trip unnecessarily.
    • After installation press the test button “T” and check that it trips.

    Quick selection guide

    2P
    C63
    30 mA
    6 kA
    DIN 35 mm
    Suitable when you need:
    • protection of one circuit against overload, short circuit and leakage
    • a leak in one circuit not to switch off the others
    • a bathroom, kitchen or outdoor socket circuit
    Check before use:
    • The residual current type (AC or A) on the housing
    • Whether 63 A matches the circuit cable cross-section
    • Whether there is enough space on the DIN rail
    Important reminder: An RCBO does not replace proper earthing – the installation must have a PE conductor.

    FAQ

    How does an RCBO differ from an RCCB?
    An RCBO also protects against overload and short circuit, an RCCB only against leakage.
    How many circuits does one device protect?
    One circuit.
    What does the C characteristic mean?
    The C characteristic tolerates higher inrush currents, so it suits general circuits with motors or transformers.
    Which residual current type is it?
    The type is marked on the housing – you can confirm it with us before buying.
    What does 6 kA mean?
    It is the highest short-circuit current the device can safely interrupt.
    How do I check that the device works?
    Press the test button “T” – a working device must trip.

    Modular residual current circuit breaker with overcurrent protection (RCBO) | 2P | 63A | C | 6kA | 0.03A | DIN | RCBO | Vecas | RCBO2P633

    Vecas RCBO2P633 – C63 30 mA RCBO 2P 6 kA for protecting one circuit against overload, short circuit and residual current.

    Published: 2026-11-15 · Manufacturer’s datasheet not available – product marking parameters are stated

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information