Modular residual current relay | 4P | 25A | 0,3A | Type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4025300A
Code: FPR4025300APrice 26.04 € VAT incl.( 21.52 € VAT excl. )Promfactor Baltic ECO FPR-A – a four-pole Type A residual current device (RCCB) designed for differential protection of three-phase electrical circuits. Rated current – 25 A, residual current sensitivity – 300 mA, operating voltage – 230/400 V AC. The device is electromechanical, mounted on a 35 mm DIN rail, protection class – IP20.
-
Modular residual current relay | 4P | 25A | 0,3A | Type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4025300A
The ECO FPR-A modular four-pole (4P) residual current device – an electromechanical residual current circuit breaker (RCCB) designed to disconnect electrical circuits when dangerous residual current is detected. A 25 A rated current, 300 mA rated residual operating current and Type A sensitivity allow this device to be used in three-phase electrical installations where protection against leakage currents caused by insulation faults and the associated fire risk is required. The RCCB is mounted on a standard 35 mm DIN rail, operates in 230/400 V AC, 50/60 Hz electrical systems and is suitable for distribution boards in residential, administrative, commercial and appropriate industrial installations.
Key point:
Not all dangerous faults in an electrical installation appear as a short circuit or a large overload current. If cable insulation is damaged, part of the current may flow not through the intended conductor but through protective earth, structural parts or other conductive surfaces. Such residual current may be too small to trip a conventional circuit breaker, yet over time it can create a fire hazard. A 300 mA Type A residual current device monitors the current balance and disconnects the circuit when the residual current reaches the tripping conditions. It is intended for residual current protection and does not replace either an overcurrent circuit breaker or mandatory 30 mA additional protection where such protection is required.⚡ Spark: Phase, if circuit breakers are already installed in the distribution board, why is a residual current device still needed?
⚙ Phase: Because the circuit breaker and the residual current device monitor different types of faults. A circuit breaker protects the circuit against overloads and short circuits, while an RCCB detects current flowing along an unintended path. This 300 mA RCCB is especially relevant for reducing the fire risk caused by insulation faults. Do not confuse it with 30 mA devices – those are used as additional protection for people against electric shock.
Poles and current
4P | 25 AResidual current sensitivity
IΔn = 300 mAResidual current protection type
Type A | electromechanicalSupply system
230/400 V AC | DIN 35 mmOperating principle
A residual current circuit breaker operates on the principle of current balance. The protected live conductors pass through its measuring transformer. During normal operation, the vector sum of the currents flowing through the phase conductors, taking into account the current returning through the neutral conductor, is equal to zero. In this condition, the RCCB tripping mechanism does not operate.
If part of the current begins to flow to earth or through another unintended path due to insulation damage or another fault, a current imbalance appears. The residual current measuring mechanism detects this imbalance and, once the specified tripping conditions are reached, initiates opening of the contacts.
The four-pole design allows four live conductors to be disconnected by one device, typically L1, L2, L3 and N in a three-phase four-wire system. The protective PE conductor is not routed through the RCCB and is not disconnected.
Type A residual current protection responds to sinusoidal alternating and pulsating direct residual currents, so it may be suitable for circuits containing certain electronic loads. However, Type A is not intended for all possible DC leakage situations – equipment capable of producing smooth direct residual current may require another type of protection.
The electromechanical residual current protection principle allows the leakage detection and tripping mechanism to operate without a separate electronic power supply. However, this does not mean that the device provides protection against every possible fault in an electrical installation.
Why is this residual current device useful?
It adds residual current protection to the electrical distribution system by detecting current imbalance that a conventional circuit breaker may not detect. The 300 mA sensitivity is relevant when designing protection against fire risk caused by insulation faults, while the four-pole construction allows protection of a three-phase circuit with a neutral conductor.Technical specifications
Product type Modular residual current circuit breaker (RCCB) Manufacturer / brand Promfactor Baltic Series ECO FPR-A Product code FPR4025300A Number of poles 4P Rated current (In) 25 A Rated residual operating current (IΔn) 0.3 A (300 mA) Residual current protection type Type A Detected residual currents Sinusoidal alternating and pulsating direct residual currents Operating principle Electromechanical Rated voltage (Un) ~230/400 V AC Rated frequency 50/60 Hz Rated insulation voltage (Ui) 500 V Rated impulse withstand voltage (Uimp) 4000 V (4 kV) Specified short-circuit current characteristic 10,000 A (10 kA) Specified disconnection time ≤0.1 s (100 ms) Electrical endurance 4000 cycles Mechanical endurance 20,000 cycles Connectable conductor cross-section Up to 25 mm² Terminal tightening torque 3.5 Nm Installation On 35 mm DIN rail Operating temperature −25 °C to +55 °C Storage temperature −25 °C to +70 °C Degree of protection IP20 Main purpose Residual current monitoring and protection against fire risk caused by leakage current, subject to the electrical installation design Main functions
- Residual current detection – monitors the current balance in live conductors and trips when leakage matching the specified conditions occurs.
- 300 mA sensitivity – intended for residual current protection, particularly relevant for reducing fire risk caused by insulation faults.
- Type A protection – responds to sinusoidal alternating and pulsating direct residual currents.
- Four-pole disconnection – allows L1, L2, L3 and N conductors to be disconnected by one mechanism in a properly designed circuit.
- 25 A rated current – intended for circuits whose design operating current and protection coordination correspond to the device ratings.
- Electromechanical operation – the residual current protection function does not require a separate electronic power supply.
- Modular DIN installation – the device integrates into standard electrical distribution boards.
- Mechanical endurance – 20,000 mechanical and 4000 electrical switching cycles.
- Wide operating temperature range – from −25 °C to +55 °C, taking into account the environmental conditions inside the distribution board.
Where is it used?
- In main and distribution electrical boards of residential buildings.
- In common electrical distribution systems of apartment buildings.
- In electrical installations of administrative and office buildings.
- In electrical distribution boards of retail, commercial and service buildings.
- In electrical distribution circuits of hotels, accommodation facilities and other commercial premises.
- In electrical systems of warehouses and utility spaces.
- In suitable three-phase circuits of industrial facilities, taking into account the nature of residual currents generated by connected loads.
- In electrical distribution solutions where 300 mA residual current protection is specified to reduce fire risk caused by leakage current.
Use by need
For the electrical designer.
The 4P, 25 A and 300 mA parameters allow the use of the device to be assessed within the residual current protection scheme of a three-phase distribution system. When selecting it, protection coordination, earthing system, short-circuit conditions and required selectivity must be checked.For the electrical installer.
The modular construction is designed for mounting on a 35 mm DIN rail. Connection of conductors up to 25 mm² and a terminal tightening torque of 3.5 Nm make it possible to plan conductor termination in accordance with the device installation instructions.For the building electrical maintenance specialist.
Residual current protection helps reduce hazards caused by long-term insulation faults. Regular device testing and determining the cause of tripping are important parts of safe electrical installation operation.Practical application
For example, in the three-phase electrical distribution board of a small commercial building, residual current protection against the fire risk caused by insulation faults is required. A correctly selected 4P, 25 A, 300 mA Type A RCCB may be installed at the intended point in the distribution circuit together with coordinated overload and short-circuit protection. If current begins to leak to earth in the connected circuit, the RCCB disconnects the circuit once the tripping conditions are reached. Meanwhile, final circuits requiring mandatory additional 30 mA protection against electric shock must be equipped with separately selected protective devices. Such a system helps distinguish the functions of different protection levels, but selectivity between them must be verified during design.Advantages
- Type A residual current protection – broader residual current detection than Type AC devices.
- 300 mA sensitivity – suitable for certain protection solutions aimed at reducing fire risk caused by leakage current.
- 4P construction – disconnection of all four live conductors.
- Electromechanical operating principle.
- Mounting on a standard 35 mm DIN rail.
- 20,000 mechanical switching cycles.
- 4000 electrical switching cycles.
- Operating temperature from −25 °C to +55 °C.
Disadvantages / limitations
- 300 mA sensitivity does not replace mandatory 30 mA additional protection against electric shock.
- There is no integrated overload or short-circuit protection, therefore a suitable protective device is required.
- Type A is not suitable for all smooth direct residual current situations.
- The 25 A rated current limits use in higher-load circuits.
- IP20 – not suitable for direct exposure to water or other unsuitable environmental influences.
- A standard 300 mA RCCB without a confirmed selective characteristic does not guarantee selective operation with downstream 30 mA RCCBs.
Safety and installation notes
- Installation work may only be performed by a qualified electrical specialist. Before starting work, safely disconnect the power supply and verify absence of voltage.
- Installation on a 35 mm DIN rail. The device must be properly secured in the electrical distribution board, ensuring safe connection and the required protection against accidental contact.
- Conductor connection. All live conductors of the protected circuit must be connected according to the device terminal markings and the original wiring diagram. The neutral conductor must not be arbitrarily connected to neutral conductors of other residual current protected circuits.
- PE conductor connection. The protective earth conductor is not routed through the RCCB. The possibility of connecting PE and N depends on the earthing system of the electrical network and applicable installation requirements.
- Rated current – 25 A. Suitable overload and short-circuit protection must be provided and its parameters coordinated with the RCCB characteristics.
- 300 mA sensitivity. This device must not be considered a substitute for 30 mA additional protection against electric shock.
- Check whether Type A is suitable. Variable frequency drives, EV charging equipment, certain photovoltaic systems and other electronic devices may require Type F, Type B or additional DC residual current monitoring.
- Terminal tightening torque – 3.5 Nm. Use suitable tools and verify compatibility of the conductor cross-section and conductor type with the terminals.
- Disconnection time. The specified ≤0.1 s duration must not be treated as universal for all residual current values. When verifying protection performance, follow the applicable tripping-time criteria and the documentation of the specific product.
- IP20 degree of protection. The RCCB must be installed in a distribution board with an appropriate degree of protection, taking into account room humidity, dust levels and other environmental conditions.
- Functional test. Test the RCCB function and perform electrical measurements according to the device instructions and applicable electrical installation maintenance requirements. Checking the test button does not replace professional measurement of protection parameters.
⚡ Phase tip:
When selecting an RCCB, first answer three questions: what type of residual current must be detected, what sensitivity is required for the specific circuit, and is the device rated current coordinated with overcurrent protection? A 300 mA RCCB may be suitable for fire prevention, but where additional personal protection is required, it is not sufficient on its own. Another common mistake is selecting Type A without assessing whether connected equipment can generate a DC residual current component that requires another protection technology.Quick selection guide
4P | 25 A300 mA | Type A230/400 V ACDIN 35 mm | IP20Suitable when you need:- four-pole residual current protection in a three-phase electrical installation
- 300 mA sensitivity to reduce the risk of fire caused by insulation faults and associated leakage currents
- Type A sensitivity to sinusoidal alternating and pulsating direct residual currents
- a modular electromechanical RCCB for DIN-rail mounting
Check before buying:- whether 300 mA rather than 30 mA residual current sensitivity is required
- whether a 4P device is actually required and compatible with the electrical network configuration
- whether the 25 A rated current complies with protection coordination requirements
- whether connected loads are compatible with Type A residual current protection
- whether suitable overload and short-circuit protection is provided
- whether a selective (Type S) RCCB is required
Important reminder: An RCCB is a residual current protection device, not a circuit breaker with integrated overcurrent protection. A 300 mA device is not intended to replace mandatory 30 mA additional protection against electric shock. Short-circuit withstand and protection coordination must be evaluated together with the protective device installed upstream.FAQ
⚡ Spark: What is the difference between 300 mA and 30 mA RCCBs?
⚙ Phase: 30 mA RCCBs are used as additional protection for people against electric shock where such protection is required. 300 mA RCCBs are more commonly used to reduce fire risk caused by leakage current. Their purposes are different, so a 300 mA RCCB is not a direct replacement for a 30 mA device.⚡ Spark: How does a Type A RCCB differ from Type AC?
⚙ Phase: Type AC is intended for sinusoidal alternating residual currents, while Type A additionally detects pulsating direct residual currents. This is important in circuits with certain electronic equipment. However, Type A does not replace Type B where detection of smooth direct residual current is required.⚡ Spark: Does this RCCB protect against short circuits and overloads?
⚙ Phase: No. An RCCB monitors residual current but does not have the conventional overcurrent protection function of a circuit breaker. Therefore, coordinated overload and short-circuit protection is required. If both functions are needed in one device, an RCBO is usually selected.⚡ Spark: Is a four-pole RCCB suitable for a three-phase network?
⚙ Phase: Yes, a 4P RCCB is typically used in a three-phase system with L1, L2, L3 and N conductors. It is important that all protected live conductors are connected correctly according to the specific product wiring diagram and that the PE conductor is not routed through the RCCB.⚡ Spark: What does 25 A mean if the residual current sensitivity is only 300 mA?
⚙ Phase: These are two different values. 25 A is the rated current and describes the device operating current load, while 300 mA is the residual operating current. The RCCB may disconnect the circuit due to leakage even when the total load current is well below 25 A.⚡ Spark: Can a 300 mA RCCB be installed upstream of several 30 mA RCCBs?
⚙ Phase: Such a protection arrangement may be used, but the difference in sensitivity alone does not guarantee selectivity. If only the RCCB closest to the fault should trip, operating times and the need for appropriate selective protection must be evaluated.⚡ Spark: Will the RCCB operate if the neutral conductor is interrupted?
⚙ Phase: The electromechanical operating principle means that residual current detection does not require a separate electronic power supply. However, an interrupted neutral conductor can create additional hazards in a three-phase installation, and this RCCB is not a dedicated neutral conductor failure monitoring device.⚡ Spark: Can I use this RCCB with a variable frequency drive or EV charger?
⚙ Phase: Only after assessing the requirements of the specific equipment. Some drives and charging devices can generate a DC component for which a Type A RCCB is not suitable. In such cases, Type B protection or another dedicated residual current monitoring solution may be required.Modular residual current relay | 4P | 25A | 0,3A | Type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4025300A
Promfactor Baltic ECO FPR-A modular electromechanical residual current circuit breaker FPR4025300A, designed for residual current detection and electrical circuit disconnection. 4P construction, 25 A rated current, 300 mA sensitivity, Type A residual current protection, 230/400 V AC supply system and mounting on a 35 mm DIN rail – a solution for distribution boards in residential, administrative, commercial and suitable industrial installations. IP20, electromechanical operation, 20,000 mechanical and 4000 electrical switching cycles. Used together with properly coordinated overcurrent protection, taking into account the electrical installation design and safety requirements.
Published: 2026-11-07 · Data verified against the manufacturer's datasheet: 2026-11-06
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products