  • Motor protection | circuit breaker | 4-6.3A | 2.2kW | MS132-6.3 | ABB | 1SAM350000R1009

    Code: 1SAM350000R1009

    ABB MS132-6.3 – a compact manual motor starter, also known as a motor protection circuit breaker, designed for manual switching, disconnection and protection of three-phase and single-phase motors against overload, short circuit and phase failure. The device has an adjustable 4-6.3A current range, is suitable for motors up to 2.2kW at 400V AC-3 and is mounted on a DIN rail. 

  • ABB MS132-6.3 motor protection circuit breaker – 3P, 4-6.3A, up to 2.2kW, 400V, DIN

    ABB MS132-6.3 – a compact manual motor starter, also known as a motor protection circuit breaker, designed for manual switching, disconnection and protection of three-phase and single-phase motors against overload, short circuit and phase failure. The device has an adjustable 4-6.3A current range, is suitable for motors up to 2.2kW at 400V AC-3 and is mounted on a DIN rail.

    Main idea:
    This device is designed for motor protection and manual control in one enclosure. It allows the motor to be safely switched on or off and protects it against overload, short circuits and phase failure, so in many cases additional fuses in the motor circuit are not required.
    Current setting
    4-6.3A
    Motor power AC-3
    Up to 2.2kW / 400V
    Poles
    3P
    Mounting
    DIN rail

    Operating principle

    The MS132-6.3 is installed in the motor supply circuit between the electrical input and the motor. By turning the front handle to the ON position, the motor circuit is switched on, and in the OFF position it is safely disconnected. The handle also clearly indicates the switch status: ON, OFF or TRIP.

    The device includes integrated thermal and magnetic protection. In the event of long-term overload, the thermal mechanism disconnects the motor according to the set current limit. In case of a short circuit, fast magnetic protection trips, and in the event of phase failure, the protection helps prevent motor overheating and damage.

    How does a motor protection circuit breaker differ from a standard circuit breaker?
    A motor protection circuit breaker has adjustable overload protection adapted to the rated current of a specific motor. Therefore, it can protect the motor more accurately against long-term overload, phase failure and short circuits than a standard circuit breaker, which is usually selected only according to the general circuit current.

    Technical parameters

    Manufacturer ABB
    Model MS132-6.3
    Manufacturer code 1SAM350000R1009
    Product type Motor protection circuit breaker / manual motor starter
    Number of poles 3P
    Current adjustment range 4.0-6.3A
    Rated operational current Ie 6.3A
    Rated current AC-3 / AC-3e 6.3A
    Rated motor power AC-3, 400V 2.2kW, 3-phase
    Rated operational voltage Up to 690V AC / up to 250V DC
    Rated insulation voltage Ui 690V
    Rated impulse withstand voltage Uimp 6kV
    Short-circuit trip current setting Ii 78.8A
    Short-circuit breaking capacity Ics, 400V AC 100kA
    Short-circuit breaking capacity Ics, 230V AC 100kA
    Short-circuit breaking capacity Ics, 440V AC 30kA
    Short-circuit breaking capacity Ics, 500V AC 20kA
    Short-circuit breaking capacity Ics, 690V AC 3kA
    Trip class Trip class 10
    Operating frequency 50 / 60 Hz, 0-400 Hz
    Power losses 0.7-1.8W per pole under rated conditions
    Electrical durability 50,000 cycles
    Mechanical durability 100,000 cycles
    Switch position indication ON / OFF / TRIP
    Disconnect function Integrated
    Temperature compensation Yes
    Handle locking Possible, for protection against unauthorized switching on or off
    Terminal type Screw terminals
    Flexible conductors 0.75-2.5 mm²
    Rigid conductors 1-4 mm²
    Wire stripping length 9 mm
    Tightening torque 0.8-1.2 N·m
    Enclosure protection class IP20
    Main circuit terminal protection class IP10
    Mounting DIN rail TH35-7.5 or TH35-15 according to IEC 60715
    Mounting positions 1-6
    Operating temperature -25°C ... +70°C
    Compensated operating temperature -25°C ... +60°C
    Storage temperature -50°C ... +80°C
    Maximum installation altitude 2000 m above sea level
    Shock resistance 25g, 11 ms impulse according to IEC 60068-2-27
    Vibration resistance 5g, 3-150 Hz
    Standards IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L

    Main functions

    • Manual motor switching on and off – clear front rotary handle.
    • Overload protection – adjustable in the 4-6.3A range according to the motor rated current.
    • Short-circuit protection – high 100kA breaking capacity at 400V AC.
    • Phase failure protection – helps protect a three-phase motor from overheating if one phase is lost.
    • Integrated disconnect function – can be used as a motor circuit disconnecting device.
    • Trip-free mechanism – the device can trip even when the handle is held in the ON position.
    • Temperature compensation – more stable protection characteristics when ambient temperature changes.
    • Lockable handle – protection against unauthorized switching on or off.
    • Accessory mounting option – auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, busbars and power in-feed blocks.

    Where is it used?

    • Pump systems – for protection of water supply, drainage, heating and process pumps.
    • Ventilation equipment – for fans, air supply and exhaust systems.
    • Compressors – for protection and control of smaller electric motors.
    • Production lines – for conveyors, smaller mechanisms and process equipment.
    • Heating and ventilation systems – for circulation pumps, fans and auxiliary loads.
    • Electrical control cabinets – as a motor protection and manual disconnecting element.
    • Commercial and residential buildings – for smaller three-phase or single-phase motor loads.

    Practical application example

    For example, a 2.2kW three-phase pump has a rated current of around 4.5-5A. In this case, the ABB MS132-6.3 is installed in the electrical cabinet before the motor, and the current adjustment dial is set according to the motor rated current shown on the motor nameplate.

    If the motor is overloaded, blocked or one phase is lost, the switch trips and disconnects the motor. After the cause of the fault has been removed, the switch is manually reset to the operating position and the motor can be restarted.

    Use according to needs

    For an electrician: a convenient DIN-mounted solution for motor protection, manual control and safe disconnection. The adjustable current allows the switch to be adapted to different motors whose rated current falls within the 4-6.3A range.

    For an automation specialist: it can be supplemented with auxiliary and signalling contacts, an undervoltage release or a shunt trip, making it easy to integrate into automation and safety circuits.

    For an industrial specialist: suitable for pumps, fans, compressors, small mechanisms and other loads requiring reliable overload and short-circuit protection.

    For a building maintenance specialist: it can be used in heating, ventilation, water supply and other building engineering systems where clear manual motor disconnection and protection are required.

    Advantages

    • Motor protection and manual switch in one device.
    • Adjustable 4-6.3A current – can be matched more accurately to the motor rated current.
    • Up to 2.2kW at 400V AC-3 – suitable for smaller three-phase motors.
    • 100kA breaking capacity at 400V – high resistance to short-circuit currents.
    • Phase failure protection – important for three-phase motors.
    • Temperature compensation – more stable operation under different ambient conditions.
    • Clear ON / OFF / TRIP indication – easier device status control.
    • Lockable handle – safer maintenance work.
    • DIN mounting – convenient in electrical cabinets.
    • Option to use additional accessories – for wider automation functionality.

    Disadvantages / limitations

    • Designed only for the 4-6.3A rated current range – another MS132 model is required for a different motor current.
    • Up to 2.2kW at 400V AC-3 – a different protection device must be selected for higher-power motors.
    • Manual starting – automatic motor control may require a contactor, PLC or additional automation.
    • IP10 terminal protection – must be installed in a suitable electrical cabinet or protected enclosure.
    • Auxiliary contacts and other accessories – purchased separately if additional signalling or remote disconnection is required.

    Safety and installation notes

    The motor protection circuit breaker must be selected according to the rated current of the specific motor, voltage, starting method and electrical installation design. Incorrectly selected or adjusted protection may cause unnecessary tripping or insufficient motor protection.

    • Installation must be carried out by a qualified electrician.
    • Before installation, disconnect the power supply and check that there is no voltage in the circuit.
    • The current setting must correspond to the motor rated current shown on the motor nameplate.
    • The protection must not be set only according to motor power – the actual rated current and motor operating conditions must be evaluated.
    • The motor cable, circuit breaker and other installation protection must be selected according to the project.
    • Connect the terminals according to the specified conductor cross-section and tightening torque of 0.8-1.2 N·m.
    • Before starting a three-phase motor, the phase sequence and direction of rotation must be checked.
    • During maintenance, it is recommended to lock the handle in the OFF position to prevent accidental switching on.

    Quick selection guide

    Choose ABB MS132-6.3 when a motor protection switch with an adjustment range from 4A to 6.3A is required. It is especially suitable for three-phase motors up to 2.2kW at 400V in AC-3 mode, but the final selection must be made according to the motor rated current.

    Current range
    4-6.3A
    Power AC-3 / 400V
    Up to 2.2kW
    Poles
    3P
    Mounting
    DIN rail
    Suitable when you need to:
    • protect a motor whose rated current is between 4A and 6.3A;
    • manually switch a motor on and off;
    • protect a motor against overload, short circuit and phase failure;
    • use a compact protection device in an electrical cabinet;
    • have a lockable disconnect handle for maintenance.
    Check before ordering:
    • whether the motor rated current falls within the 4-6.3A range;
    • whether the motor power at 400V does not exceed 2.2kW in AC-3 mode;
    • whether auxiliary or signalling contacts are required;
    • whether an undervoltage release or shunt trip is required;
    • whether there is enough space in the panel for DIN mounting and safe wire connections;
    • whether automated motor control with a contactor is required.
    Important reminder:
    The motor protection circuit breaker must be set according to the rated motor current, not only according to kilowatts. Before starting, the motor nameplate, cable cross-section, phase sequence and the protection of the entire motor circuit must be checked.

    FAQ – frequently asked questions

    What is the ABB MS132-6.3 used for?
    It is designed for manual switching on, switching off and protection of three-phase or single-phase electric motors against overload, short circuit and phase failure.
    What motor power is it suitable for?
    At 400V in AC-3 mode, it is suitable for a three-phase motor up to 2.2kW, but the most important criterion is the motor rated current, which must be from 4A to 6.3A.
    Is an additional thermal relay required?
    Usually no, because the MS132 series switch already includes adjustable overload protection. However, the specific motor control circuit must be selected according to the project and operating conditions.
    Can it be used without a fuse?
    The device has integrated short-circuit protection and is intended for motor protection without an additional fuse, but the protection solution for the entire installation must comply with the specific project and applicable requirements.
    Can the switch be locked?
    Yes, the handle can be locked to prevent unauthorized or accidental motor start-up during maintenance.
    Is it suitable for automatic motor starting?
    The switch is intended for manual starting and protection. For automatic control via PLC, timer, pressure relay or other automation, a contactor is usually used additionally.

    Reliable ABB motor protection for smaller three-phase motors

    ABB MS132-6.3 is a compact and professional motor protection circuit breaker designed for motors in the 4-6.3A current range. It combines manual control, overload protection, short-circuit protection and phase failure protection in one device.

    Thanks to its 3P design, adjustable current, 100kA short-circuit breaking capacity at 400V, DIN mounting, temperature compensation and the option to use additional accessories, this switch is suitable for pumps, fans, compressors, small production machines and various building engineering systems.