  • Motor start potential relay | single-phase motor | 16 A FLA / 35 A RES 277 V | P.U. 180–195 V AC | OURTOP ATR3F-4G3D

    Code: ATR3F-4G3D

    Potential (voltage) relay for starting single-phase motors with a start capacitor: once the coil voltage reaches 180–195 V AC after start-up, the relay disconnects the start capacitor.

  • Motor start potential relay | single-phase motor | 16 A FLA / 35 A RES 277 V | P.U. 180–195 V AC | OURTOP ATR3F-4G3D

    Potential (voltage) relay for starting single-phase motors with a start capacitor: once the coil voltage reaches 180–195 V AC after start-up, the relay disconnects the start capacitor. Used in compressors, pumps and refrigeration equipment.

    Key point:
    A potential relay is the guardian of the start circuit of a single-phase motor with a start capacitor: it disconnects the capacitor on time and protects the start winding. The key is selecting it by the pick-up voltage (P.U.) specified by the compressor or motor manufacturer.
    Pick-up voltage (P.U.)
    180–195 V AC
    Drop-out voltage (D.O.)
    40–105 V AC
    Contact rating
    FLA 16 A / RES 35 A, 277 V
    Mounting
    faston

    Operating principle

    The relay is wired into the motor start circuit: its contact in series with the start capacitor, and its coil across the start winding according to the diagram.

    As the motor starts, the voltage across the start winding rises with speed; at 180–195 V AC the relay picks up and disconnects the start capacitor.

    When the motor stops, the voltage falls below 40–105 V AC, the relay drops out and readies the circuit for the next start.

    Why choose ATR3F-4G3D?
    A correctly selected potential relay prevents the start capacitor and winding from overheating, so the compressor or pump lasts longer.

    Technical specifications

    Product typeMotor start potential relay
    Manufacturer / modelOURTOP ATR3F-4G3D
    Pick-up voltage (P.U.)180–195 V AC
    Drop-out voltage (D.O.)40–105 V AC
    Contact ratingFLA 16 A 277 V 50 Hz · RES 35 A 277 V
    Rated currentsIe 16 A 400 V 50 Hz · Ith 50 A 400 V
    MountingFlat (faston) terminals
    MarkingCE

    Key functions

    • Start capacitor disconnection – by voltage, not by time.
    • P.U. 180–195 V AC – clearly defined pick-up voltage.
    • D.O. 40–105 V AC – reliable reset for the next start.
    • FLA 16 A / RES 35 A, 277 V – contacts rated for start currents.
    • Flat (faston) terminals – quick replacement in service.

    Where is it used?

    • Refrigeration and air-conditioning compressors
    • Single-phase pumps with a start capacitor
    • Air compressors and pneumatics
    • Cold rooms and commercial refrigerators
    • Single-phase fan and drive motors
    • Service repairs and spare parts

    Use by need

    For the service technician.
    Quick replacement of a failed start relay by P.U. / D.O. values.
    For the refrigeration technician.
    The compressor start circuit works again without an overheated capacitor.
    For the equipment builder.
    A compact relay with faston terminals for single-phase motor start circuits.

    Practical example

    If a cold-room compressor struggles to start and the start capacitor overheats, a failed potential relay is a common cause. ATR3F-4G3D is a suitable replacement if the manufacturer-specified P.U. matches 180–195 V AC.

    Advantages

    • Clear P.U. and D.O. values
    • Contacts FLA 16 A / RES 35 A
    • Ith 50 A / Ie 16 A 400 V
    • Faston terminals for quick replacement
    • Suits compressors and pumps

    Limitations

    • Only for motors whose manufacturer specifies a matching P.U.
    • No motor overload protection
    • The motor wiring diagram is needed for installation

    Safety and installation notes

    • Install only with the power disconnected; work in the panel must be done by a qualified electrician.
    • Discharge the start and run capacitors before working.
    • Select the relay by the P.U. / D.O. and contact current specified by the motor or compressor manufacturer.
    • Observe the mounting position and wiring diagram shown on the relay or motor.

    Quick selection guide

    P.U. 180–195 V
    D.O. 40–105 V
    FLA 16 A
    RES 35 A
    faston
    Suitable when you need:
    • Replace a failed potential relay
    • Start a single-phase motor with a start capacitor
    • A relay with P.U. 180–195 V AC
    Check before use:
    • The P.U. specified by the motor / compressor manufacturer
    • That the start current is within the contact rating
    • Terminal type and mounting position
    Important: ATR3F-4G3D only controls start-capacitor disconnection – it does not protect the motor from overload or replace motor protection or a circuit breaker.

    FAQ

    How do I select a potential relay?
    By the P.U. / D.O. and contact current specified by the motor or compressor manufacturer.
    What do P.U. and D.O. mean?
    P.U. is the voltage at which the relay picks up (180–195 V AC), D.O. the voltage at which it drops out (40–105 V AC).
    Is it suitable for three-phase motors?
    No, it is for single-phase motors with a start capacitor.
    What are the contact ratings?
    FLA 16 A and RES 35 A at 277 V; Ie 16 A and Ith 50 A at 400 V.
    How is it connected?
    With flat (faston) terminals according to the motor diagram.
    Does it protect the motor from overload?
    No, separate motor protection is required for that.

    Motor start potential relay | single-phase motor | 16 A FLA / 35 A RES 277 V | P.U. 180–195 V AC | OURTOP ATR3F-4G3D

    ATR3F-4G3D is a single-phase motor start potential relay with P.U. 180–195 V AC, D.O. 40–105 V AC and FLA 16 A / RES 35 A contacts. Suitable for compressor, pump and refrigeration start circuits and service repairs.

    Published: 2026-11-19 · Data verified against the manufacturer specification: 2026-11-19

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • privacy policy

    Information