  • Mounting bracket for DTS-M / DTS-L temperature sensors | DC01 steel | Sentera Controls | DTS-MB-BK-ASM

    Code: DTS-MB-BK-ASM
    Price 16.20 € VAT incl.
    ( 13.39 € VAT excl. )
    25.26 € You save 9.06 €
    Offer is valid until 2026-12-31
    Want another price? Suggest yours!
  • Mounting bracket for DTS-M / DTS-L temperature sensors | DC01 steel | Sentera Controls | DTS-MB-BK-ASM

    DTS-MB-BK-ASM – a Sentera Controls mounting bracket for DTS-M and DTS-L duct temperature transmitters. It allows the transmitter to be fixed to a flat surface, e.g. a room wall, and thus used not only in a duct.

    Key idea:
    When a DTS-M transmitter has to be mounted not in a duct but on a wall or structure, the bracket with all screws, plugs and the cable gland solves the mounting without improvisation.
    Compatibility
    Sentera DTS-M and DTS-L
    Material
    Non-alloy steel DC01, 1.2 mm
    Installation
    On a flat surface (wall)
    Kit
    Bracket, plugs, screws, cable gland

    Operating principle

    The 1.2 mm cold-rolled unalloyed steel DC01 (DIN EN 10130) bracket is fixed to the wall with 3 screws and wall dowels, and the transmitter is fixed to it with 2 sets of stainless steel screws, nuts and washers; the cable enters through the supplied cable gland.

    The transmitter probe remains freely washed by the ambient air, so the duct DTS-M measures the temperature of a room or technical zone and passes it on over the Modbus RTU network.

    Result – the same Modbus sensor is used both in a duct and on a wall. The bracket is a mechanical accessory with no electrical parameters, and the sensor (DTS-M-080 / DTS-M-160) is purchased separately.

    Benefits DTS-MB-BK-ASM?
    The complete mounting kit in one package – no need to look for screws and a cable gland on site.

    Technical specifications

    Product type Temperature sensor mounting bracket
    Manufacturer / code Sentera Controls / DTS-MB-BK-ASM
    Compatibility Sentera DTS-M, DTS-L
    Material Non-alloy steel DC01 (DIN EN 10130)
    Thickness 1.2 mm
    Mounting holes 2 × Ø5 mm, 3 × Ø4 mm; openings Ø12.5 and Ø17 mm
    Scope of delivery Bracket 1 pc.; wall plugs 3 pcs.; screws 3 pcs.; stainless steel screw, nut and washer 2 sets; cable gland with nut 1 set.
    Package (1 pc.) 106 × 88 × 96 mm
    Weight 0.102 kg (net)

    Manufacturer documentation

    ✔ Recommended by Elektrotechnikos sprendimai

    Original manufacturer documentation – technical data, wiring diagrams and installation instructions.

    Main functions

    • Wall mounting – The DTS-M transmitter is mounted on a flat surface.
    • Complete kit – 3 pins, 3 screws and a cable gland are included.
    • Stainless steel fasteners – 2 sets of screws, nuts and washers for mounting the transmitter.
    • Steel bracket – 1.2 mm DC01 steel – sturdy base.
    • Cable gland – neat cable entry.
    • Compatibility – suitable for Sentera DTS-M and DTS-L transmitters.

    Where is it used?

    • Mounting the DTS-M transmitter on a room wall
    • Technical room temperature measurement on the Modbus network
    • Ventilation chambers – sensor on the structure
    • Warehouses – sensor on a column or wall
    • Server rooms and electrical switchgear rooms
    • Mounting the transmitter next to the equipment on a flat surface

    On-demand operation

    For the electrical installer.
    The complete mounting kit – dowels, screws and cable gland – in one package.
    For the BMS integrator.
    The same DTS-M sensor and Modbus registers are used both in a duct and on a wall.
    For building administrators.
    Technical room temperature in a Modbus network without a separate room sensor type.

    Practical application

    If the air temperature of a server room has to be added to an existing Sentera Modbus network, then the DTS-M-080 is fixed to the wall with the DTS-MB-BK-ASM bracket using 3 screws with pins, and the cable is routed through the supplied cable gland.

    Application guide: how it is used in practice

    The DTS-MB-BK-ASM is used together with a DTS-M transmitter:

    Site What is connected Result Installer's note
    Plant room DTS-M-080 + DTS-MB-BK-ASM on a wall → Modbus Room temperature on the Modbus network Install away from heat sources
    Ventilation chamber DTS-M-160 + bracket on a structure Chamber air temperature monitoring Route the cable through the gland
    Warehouse DTS-M + bracket on a column → BMS Warehouse temperature in the BMS Use the supplied plugs and screws

    How to choose a Modbus temperature transmitter

    Installation location / probe Recommended model
    Duct, 85 mm probe DTS-M-080 (duct, 85 mm)
    Duct, 165 mm probe DTS-M-160 (duct, 165 mm)
    Water pipe, strap-on DTP-M (pipe, 0–85 °C)
    DTS-M wall fixing DTS-MB-BK-ASM (bracket) ← this model
    Rule: the bracket suits DTS-M (and DTS-L) transmitters; choose the transmitter itself by probe length – 85 mm (DTS-M-080) or 165 mm (DTS-M-160).
    When to choose another solution: for a passive room sensor in a wall-mounted housing – ROTSN series; for a water pipe – DTP-M.

    Pros

    • Complete mounting kit
    • Sturdy 1.2 mm steel bracket
    • Cable gland included
    • Suitable for DTS-M and DTS-L
    • The probe remains freely washed by air

    Cons / limitations

    • The transmitter is not included in the kit
    • Non-alloy steel – not stainless
    • For flat surfaces only; for a passive wall sensor there is the ROTSN series

    Safety and installation notes

    • Before drilling, check that there are no hidden wires or pipes in the wall.
    • The transmitter is to be connected by a qualified installer with the power disconnected.
    • Use the supplied fasteners.

    Quick selection guide

    DTS-M
    DTS-L
    Bracket
    DC01 steel
    Suitable when you need:
    • to fix a DTS-M transmitter to a wall;
    • to measure room temperature using a Modbus sensor;
    • to route the cable neatly through the cable gland.
    Check before use:
    • whether you have a DTS-M or DTS-L sensor;
    • whether the surface is flat;
    • the wall material and suitability of the dowels.
    Important reminder: The DTS-MB-BK-ASM is a bracket only; the temperature transmitter is ordered separately.

    FAQ

    Is the transmitter included in the kit?
    No, it is only a bracket with fasteners.
    Which transmitters is it suitable for?
    The bracket is suitable for Sentera DTS-M and DTS-L transmitters.
    What is it made of?
    It is made of 1.2 mm DC01 unalloyed steel.
    What is included?
    Includes a bracket, 3 dowels, 3 screws, 2 sets of stainless steel screws and a cable gland.
    Can it be mounted on an uneven surface?
    No, the bracket is designed for flat surfaces such as a wall or column.
    How much does the bracket weigh?
    The bracket weighs 0.102 kg.

    Mounting bracket for DTS-M / DTS-L temperature sensors | DC01 steel | Sentera Controls | DTS-MB-BK-ASM

    Sentera DTS-MB-BK-ASM – steel mounting bracket for wall mounting of DTS-M and DTS-L temperature sensors, with dowels, screws and a cable gland.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.