    Smart alarm and annunciation terminal – a programmable 24-channel device designed for monitoring status and alarm signals in electrical substations, power plants and industrial automation systems. The terminal features a 9" colour touchscreen LCD, integrated audible alarm and SOE event recording with up to 1 ms accuracy. It supports Modbus RTU, IEC 61850 Server / MMS, GOOSE, DNP3.0 and IRIG-B, allowing integration with SCADA and other higher-level control systems. 

  • Smart alarm and annunciation terminal | 24 inputs | 9" touchscreen LCD | 24V DC | IEC 61850 | GOOSE | DNP3.0 | Modbus RTU

    Smart alarm and annunciation terminal – a programmable networked device for visual and audible alarm indication and event recording, designed for monitoring operating states and fault signals in electrical substations, power plants, industrial facilities, energy systems and other control systems.

    The device features 24 alarm / status inputs, a 9" colour touchscreen LCD, audible alarm indication and SOE (Sequence of Events) recording with time resolution of up to 1ms. This version is designed for 24V DC power supply and 24V DC status signals.

    Alarm terminal for power and industrial automation

    A single device combines 24-channel alarm acquisition, colour indication, audible signalling, alarm acknowledgement, reset, event recording and communication with higher-level SCADA / substation control systems.

    24
    Alarm inputs
    9"
    Colour touchscreen LCD
    24V DC
    Power supply / status signals
    1ms
    SOE event recording

    Main application

    The terminal is designed to centrally receive, process and display various fault, process and status signals to the operator. Up to 24 individual alarms can be displayed on one screen.

    The system can be used either as a standalone 24-channel alarm terminal or as part of a larger networked annunciation system in which several similar terminals are interconnected.

    From a single control panel to a large substation system

    The network architecture allows information and alarms to be exchanged between multiple terminals and enables integration into substation, power plant or industrial control systems.

    24 alarm and status inputs

    The standard configuration includes 24 alarm inputs. In this version, the input signal voltage is 24V DC.

    The inputs are optoelectrically isolated, providing electrical isolation between the control electronics and external status signal circuits.

    Parameter Specification
    Number of alarm inputs 24
    Status input voltage 24V DC
    Input isolation Optoelectronic
    SOE recording Up to 1ms time resolution

    9" colour touchscreen LCD

    The device uses a 9" colour LCD with LED backlight and capacitive touch control. Display resolution – 800x480 pixels.

    In the standard 24-alarm configuration, approximately 30x25mm of screen area is allocated to each alarm.

    Configurable alarm display

    Each alarm can be individually configured according to the control logic of the installation. Different colours can be used on the screen to distinguish alarm type or priority.

    Alarm background colours Red, yellow, green, white
    Alarm colours Red, yellow, green, white
    Font colour Configurable
    Flashing function Yes
    Audible alarm Integrated

    Alarm acknowledgement and reset

    The operator can select a flashing alarm simply by touching it on the screen or by using the navigation arrows.

    Once an alarm is selected, the Accept function can be used to acknowledge it, while Reset restores the status according to the configured operating logic.

    Pressing and holding an alarm field or using the Enter function opens more detailed alarm information.

    Physical control buttons

    Button group Functions
    Operating buttons Audio Silence, Reset, Accept, Lamp Test
    Navigation buttons Up, down, left, right, Confirm / Enter

    LED status indicators

    Separate front-panel LED indicators provide a quick overview of the main device states.

    • Audio Silence – audible alarm mute status.
    • Fail – fault status.
    • Run – normal device operation.
    • Lamp Test – indication test status.

    SOE – Sequence of Events recording

    The alarm terminal includes a Sequence of Events (SOE) function for recording the time of status changes.

    Up to 1ms time resolution

    Event recording with up to 1ms resolution makes it possible to reconstruct the sequence of fault or process events more accurately and to analyse the operation of protection, automation and control functions.

    Communication protocols

    This version is intended for integration into industrial and power-system communication networks and supports several major communication protocols.

    Protocol Configuration
    Modbus RTU Yes – default protocol
    IEC 61850 Server Yes – MMS
    IEC 61850 GOOSE Yes
    DNP3.0 Yes
    IRIG-B Yes – for time synchronisation

    IEC 61850 integration

    The terminal supports IEC 61850 Server functionality with MMS data exchange and GOOSE communication.

    This enables integration into modern substation automation systems and allows status and alarm information to be transferred to a higher-level control or SCADA system.

    DNP3.0 and Modbus RTU

    DNP3.0 support allows the terminal to be used in power-system telecontrol and remote-control systems, while Modbus RTU enables integration into standard industrial automation systems.

    IRIG-B time synchronisation

    The integrated time synchronisation port supports the IRIG-B protocol. Accurate time synchronisation is particularly important when SOE recording is used and event timestamps from several devices need to be compared.

    Networked system

    Devices can be connected into a network, allowing information and alarms from other terminals connected to the same network to be viewed on one terminal, depending on the system configuration.

    An integrated WEB-type viewing function is used for this purpose, allowing information from other system devices to be accessed from one terminal.

    Ethernet and serial interfaces

    Ethernet 4x RJ45 / 100M
    RS232 2 ports
    RS485 2 ports
    CAN 1 port
    Time synchronisation IRIG-B

    Audible alarm indication

    The terminal has an integrated audible alarm function. The operator can mute the audible signal using the Audio Silence function without clearing the alarm displayed on the screen.

    This makes it possible to separate the alarm's audible notification, acknowledgement and final reset.

    Display ON/OFF modes

    Display operation can be configured according to the requirements of the control centre.

    • Switch on by touching the screen or pressing a button
    • Switch off after 10 minutes
    • Switch off after 30 minutes
    • Switch on when an alarm occurs
    • Continuous display operation

    Technical specification

    Product type Smart alarm and annunciation terminal
    Number of alarm inputs 24
    Status input voltage 24V DC
    Power supply voltage 24V DC
    Display 9" colour LCD, LED backlight, capacitive touchscreen
    Display resolution 800x480 pixels
    Screen area per alarm Approx. 30x25mm when using the 24-alarm screen
    SOE time resolution 1ms
    Default protocol Modbus RTU
    IEC 61850 Server / MMS
    GOOSE Supported
    DNP3.0 Supported
    Time synchronisation IRIG-B
    Ethernet 4x RJ45 / 100M
    RS232 2x
    RS485 2x
    CAN 1x
    Control buttons Audio Silence, Reset, Accept, Lamp Test + 5 navigation buttons
    LED indicators Audio Silence, Fail, Run, Lamp Test
    Audible alarm Integrated
    Degree of protection IP40
    Mounting type Flush mounting in the front of the panel
    Fixing 4x M3 screws
    Device dimensions 223x178x142mm
    Panel cut-out size 225x179mm
    Front panel Silver-coloured metal alloy
    Enclosure Black metal alloy
    Operating temperature −20°C...+70°C
    Weight Approx. 2.93kg

    Standards and electromagnetic immunity

    Test / standard Compliance
    Electrical relay insulation tests IEC 60255-27 / DLT 721-2000
    Voltage dips IEC 61000-2-8 / GBT 17626.11, category 3
    Electrical fast transients / Burst IEC 61000-4-4 / GBT 17626.4, Level 4
    Surge immunity IEC 61000-4-5 / GBT 17626.5, Level 4
    Electrostatic discharge IEC 61000-4-2 / GBT 17626.2, Level 4
    Power-frequency magnetic field IEC 61000-4-8 / GBT 17626.8, Level 4
    RF electromagnetic field immunity IEC 61000-4-3
    Distribution network automation RTU requirements DLT 721-2000

    Advantages

    • 24 alarm inputs in one device.
    • 9" colour touchscreen display.
    • 1ms SOE event recording.
    • IEC 61850 Server / MMS.
    • IEC 61850 GOOSE communication.
    • DNP3.0 support.
    • Modbus RTU.
    • IRIG-B time synchronisation.
    • 4 Ethernet ports.
    • RS232, RS485 and CAN interfaces.
    • Configurable alarm display.
    • Integrated audible alarm.
    • Alarm Accept, Reset, Audio Silence and Lamp Test functions.
    • Wide operating temperature range of −20...+70°C.

    Disadvantages / limitations

    • IP40: intended for installation inside a protected electrical or automation panel.
    • 24V DC inputs in this version: other signal voltages require a different configuration.
    • Integration into an IEC 61850 system requires appropriate substation communication design and configuration.

    Suitable for

    • Electrical substations
    • Power plants
    • Industrial control centres
    • SCADA systems
    • Centralisation of fault and alarm signals
    • SOE event recording
    • Power-system automation systems
    • Status monitoring in commercial and industrial facilities

    Not suitable for

    • Direct switching of power loads
    • Open outdoor installation without an additional protective enclosure
    • Systems that do not require advanced alarm or event recording
    • Projects requiring a status input voltage other than 24V DC

    Practical application example

    In an electrical substation, 24 different 24V DC status signals are connected to the terminal: circuit breaker status, protection relay signals, transformer alarms, DC system, UPS and other equipment states.

    When one of the fault signals appears, the corresponding alarm field on the display starts flashing in the selected colour and the audible alarm is activated.

    The operator selects the alarm on the touchscreen and presses Accept. The audible signal can be muted using Audio Silence, while the alarm itself remains visible until the cause is cleared.

    The event timestamp is recorded in the SOE log with up to 1ms resolution, while the information can be transmitted to the substation SCADA system via IEC 61850, DNP3.0 or Modbus.

    IRIG-B synchronisation allows event timing to be aligned with other protection, metering and automation systems.

    Frequently asked questions (FAQ)

    How many alarm inputs does this device have?

    24.

    What is the input signal voltage?

    24V DC.

    What is the device supply voltage?

    24V DC.

    What type of display is used?

    9" colour LCD with LED backlight and capacitive touch control.

    What is the display resolution?

    800x480 pixels.

    Is Modbus supported?

    Yes. Modbus RTU is provided as the default protocol.

    Is IEC 61850 supported?

    Yes. IEC 61850 Server / MMS and GOOSE functionality are supported.

    Is DNP3.0 supported?

    Yes.

    Is time synchronisation available?

    Yes. IRIG-B time synchronisation is supported.

    What is the SOE event recording accuracy?

    Time resolution – up to 1ms.

    Can the alarm colours be changed?

    Yes. Red, yellow, green and white alarm and background colours are available.

    Is there an audible alarm?

    Yes. An integrated audible alarm with Audio Silence function is provided.

    Can multiple terminals be connected into a network?

    Yes. The system is designed for a multi-terminal network architecture.

    What is the degree of protection?

    IP40.

    What is the operating temperature range?

    From −20°C to +70°C.

    Important configuration information

    Configuration: 24 alarm inputs, 24V DC power supply, 24V DC status inputs, Modbus RTU, IEC 61850 Server / MMS, GOOSE, DNP3.0 and IRIG-B time synchronisation.

    Smart alarm and annunciation terminal – a programmable 24-channel visual and audible annunciation device for electrical substations, power plants and industrial control systems. Equipped with a 9" colour touchscreen LCD, 24V DC alarm inputs, SOE recording with up to 1ms resolution and network communication functions. Supports Modbus RTU, IEC 61850 Server / MMS, GOOSE, DNP3.0 and IRIG-B time synchronisation.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • privacy policy

    Information