FLTSN-P500P400 – a Sentera Controls passive platinum PT500 temperature probe in a black ABS plastic tube with 4 m shielded cable, IP65. Intended for measuring temperature in HVAC systems, indoors and outdoors.
Key idea:
When the sensor has to be routed farther from the controller – outdoors, into a chamber or a thermowell – the 4 m shielded cable and IP65 probe make this possible without intermediate connections.Sensing element
PT500 (500 Ω at 0 °C)Cable length
4 m, shieldedOperating temperature
-20…+60 °CProtection class
IP65Operating principle
An acrylic-coated platinum PT500 element placed in a black ABS plastic tube with a 4 m two-core shielded 0.5 mm² cable (white sheath, tinned ends). Two-wire connection: the blue core is the sensor element, and the brown core is connected to the shield and reduces electromagnetic interference.
The element resistance rises linearly with temperature: 500 Ω at 0 °C, ≈ 616 Ω at 60 °C (temperature coefficient 3850 ppm/K), so no calibration is needed; response time t0.9 ≤ 5 s at an airflow of 3 m/s.
Result – a controller with a PT500 input receives the temperature with F0.3 class accuracy (±0.30 °C at 0 °C … ±0.60 °C at 60 °C) from a point up to 4 m away, with no intermediate connections. Thanks to IP65 the probe can also be used outdoors, but the operating range is limited to -20…+60 °C, and there is no active 0-10 VDC or Modbus output.
Benefits FLTSN-P500P400?
IP65 probe with 4 m shielded cable – one product suits indoors, outdoor air and a thermowell.Technical specifications
Product type Passive temperature sensor with cable (platinum resistance, RTD) Manufacturer / code Sentera Controls / FLTSN-P500P400 Series FLTSN-PxxxP (PT500 / PT1000, ABS probe, 1–16 m) Sensing element PT500, 500 Ω at 0 °C, ≈ 616 Ω at 60 °C Temperature coefficient 3850 ppm/K (0–100 °C) Accuracy class F0.3 (IEC 60751): ±0.30 °C at 0 °C … ±0.60 °C at 60 °C Response time t0.9 ≤ 5 s (3 m/s airflow) Long-term stability Better than ±0.04 % Probe Black ABS plastic tube, acrylic-coated element Cable 4 m, 2-core, shielded, 0.5 mm², white sheath, tinned ends Connection Two-core: blue – element, brown – shield Protection class IP65 Operating environment -20…+60 °C, < 95 % rH Weight 0.16 kg (net, 1 pc.) Compliance LVD 2014/35/EU, EMC 2014/30/EU, WEEE 2012/19/EU, RoHS (EU) 2015/863 Manufacturer documentation
✔ Recommended by Elektrotechnikos sprendimaiOriginal manufacturer documentation – technical data, wiring diagrams and installation instructions.
Main functions
- Platinum PT500 element – linear characteristic per IEC 60751 (3850 ppm/K), no calibration needed.
- IP65 ABS probe – suitable for rooms and outdoor air.
- 4 m shielded cable – fewer disturbances, no intermediate connections.
- Two-wire connection with a shield – blue wire – element, brown – shield; easy to connect.
- Accuracy class F0.3 – ±0.30 °C at 0 °C … ±0.60 °C at 60 °C.
- Fast response – t0.9 ≤ 5 s at an airflow of 3 m/s.
- Long-term stability – better than ±0.04 % – readings do not drift.
Where is it used?
- Outdoor air temperature measurement (IP65)
- Air handling unit ducts and chambers
- Heating and cooling pipework up to +60 °C (with thermowell)
- Buffer tanks and heat substations up to +60 °C
- BMS temperature monitoring
- Remote measuring points up to 4 m from the controller without junction boxes
- Greenhouses, warehouses and farm buildings
On-demand operation
For heat substation installers.
A 4 m shielded cable reaches the tank or piping from the controller cabinet without intermediate joints.For outdoor air sensor installers.
The IP65 probe can be placed outside the wall, with the 4 m cable routed to the controller.For maintenance companies.
A continuous shielded cable – fewer connections where faults occur.Practical application
If the outdoor air temperature has to be measured on a north wall and the controller with a PT500 input is 3 m away indoors, then the FLTSN-P500P400 IP65 probe is mounted outdoors and the 4 m cable is routed in without joints.Application guide: how it is used in practice
FLTSN-P500P400 is a universal probe with cable; it can be placed in a thermowell, fixed in a duct or in a room:
Site What is connected Result Installer's note Heating substation, tank FLTSN-P500P400 in a thermowell → controller PT500 input The controller regulates according to water temperature Use thermally conductive paste in the thermowell Air handling unit chamber FLTSN-P500P400 in the airflow → controller Supply or outdoor air temperature measurement Secure the wire so that it is not strained Heating circuit FLTSN-P500P400 on the pipe surface → controller Return water temperature control Insulate the sensor location so that the readings are not reduced BMS modernization The existing PT500 probe is replaced with FLTSN-P500P400 Same characteristic – no need to change settings Check the controller's input type How to choose a sensing element and cable length
Sensing element / probe / cable Recommended model PT100, stainless steel probe, 1 m FLTSN-P100-100 (PT100, 1 m) PT500, stainless steel probe, 1 m FLTSN-P500-100 (PT500, 1 m) PT500, stainless steel probe, 4 m FLTSN-P500-400 (PT500, 4 m) PT1000, stainless steel probe, 1 m FLTSN-P1K0-100 (PT1000, 1 m) PT1000, stainless steel probe, 4 m FLTSN-P1K0-400 (PT1000, 4 m) PT500, ABS probe, IP65, 1 m FLTSN-P500P100 (PT500, 1 m) PT500, ABS probe, IP65, 4 m FLTSN-P500P400 (PT500, 4 m) ← this model PT500, ABS probe, IP65, 8 m FLTSN-P500P800 (PT500, 8 m) PT500, ABS probe, IP65, 16 m FLTSN-P500P1K6 (PT500, 16 m) PT1000, ABS probe, IP65, 1 m FLTSN-P1K0P100 (PT1000, 1 m) NTC 3 kΩ (25 °C), 1 m FLTSN-N3K3A1-100 (NTC, 1 m) NTC 10 kΩ (25 °C), 1 m FLTSN-N1K4A1-100 (NTC, 1 m) Rule: the sensing element (PT100 / PT500 / PT1000 / NTC) must match the controller input, and for NTC – also its resistance characteristic. Choose a cable length that avoids splices; for extension use only a shielded cable.When to choose another solution: for a room – ROTSN series (wall-mounted housing); for a duct – TUTSN series (150 / 250 mm); when the controller accepts only Modbus RTU – DTS-M (duct) or DTP-M (strap-on).Pros
- No power supply or settings needed
- Standard PT500 characteristic
- IP65 – also suitable outdoors
- Factory-fitted 4 m shielded cable
- Accuracy class F0.3
- Long-term stability
Cons / limitations
- No 0-10 VDC or Modbus output – a controller with a PT500 input is required; for a Modbus system choose DTS-M or DTP-M
- Operating range -20…+60 °C – not suitable for hotter media
- The thermowell is not included in the kit
- The plastic (ABS) probe is mechanically less robust – for a sturdier solution there is the FLTSN-P series with a stainless steel probe
Safety and installation notes
- Installation and connection are to be carried out by a qualified installer.
- For extension use only a shielded cable, routed separately from 230 V lines.
- Do not exceed the operating temperature of -20…+60 °C and < 95 % rH non-condensing.
- Secure the cable so that it is not strained or damaged.
Quick selection guide
PT5004 mIP65PassiveWith cableSuitable when you need:- to measure temperature for a controller with a PT500 input;
- to install a sensor in a thermowell, duct or on a surface;
- to replace an old probe of the same type.
Check before use:- the controller input type (PT500);
- the required cable length;
- the medium temperature – whether it does not exceed +60 °C.
Important reminder: FLTSN-P500P400 is a passive sensor; it works only with a controller that has a PT500 input.FAQ
Is a power supply needed?
No, it is a passive resistive sensor, and the measuring current is supplied by the controller.What is the cable length?
The factory-fitted shielded cable is 4 m, and the series comprises 1, 4, 8 and 16 m variants.Can the cable be extended?
Yes, use a shielded cable for extension.What is the operating temperature range?
The probe operates within -20…+60 °C.Can it be used outdoors?
Yes, the probe is IP65, but the operating range is limited to -20…+60 °C.How does it differ from FLTSN-P500-100?
The FLTSN-PxxxP has an ABS probe with IP65 and longer cables, while the FLTSN-P series has a stainless steel tube.Passive temperature sensor with cable | PT500 | 4m | -20-60°C | IP65 | Sentera Controls | FLTSN-P500P400
Sentera FLTSN-P500P400 – passive PT500 temperature probe with a 4 m shielded cable, IP65 ABS tube and accuracy class F0.3 for HVAC controllers.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review