Products catalog

  • Potentiometer for EC fan 10kΩ with OFF position and dry contact | Sentera Controls | MTPNX10K-NA

    Code: MTPNX10K-NA
    Price 31.58 € VAT incl.
    ( 26.10 € VAT excl. )
    49.27 € You save 17.69 €
    Offer is valid until 2026-12-31
    Want another price? Suggest yours!
  • Potentiometer for EC fan 10kΩ with OFF position and dry contact | Sentera Controls | MTPNX10K-NA

    MTPNX10K-NA – Sentera Controls 10 kΩ potentiometer for an EC fan, supplied directly from the EC fan (0–12 VDC). The knob changes the output steplessly from 0 V to the supply voltage, and the end position is OFF with an open dry contact.

    Key idea:
    The cheapest and simplest manual control of an EC fan: no separate supply is needed – the potentiometer uses the fan's auxiliary DC voltage, and the dry contact additionally allows external equipment to be switched on or off.
    Resistance
    10 kΩ
    Power supply
    0–12 VDC from EC fan
    Output
    0 V – Us (max. 12 VDC / 1 mA)
    OFF / contact
    Yes / dry contact

    Operating principle

    The potentiometer is connected to the EC fan control terminals: supply – from the fan's DC output, signal – to the fan's control input.

    This is a passive 10 kΩ potentiometer, not a power controller: analogue control signal – no more than 12 VDC / 1 mA.

    When the knob is turned fully anticlockwise, it locks in the OFF position: output 0 V, dry contact open. When turned clockwise – the contact closes and the signal increases steplessly.

    Engineer's note: the output maximum equals the voltage supplied by the fan – if the fan supplies 10 VDC, the full 0-10 V range is obtained.

    Benefits MTPNX10K-NA?
    No power supply unit, trimmers or programming needed – three wires to the fan, and the user has manual control with OFF.

    Technical specifications

    Product type 10 kΩ potentiometer for an EC fan
    Manufacturer / code Sentera Controls / MTPNX10K-NA
    Resistance 10 kΩ
    Power supply 0–12 VDC (from EC fan)
    Output 0 V – supply voltage, stepless
    Max. analogue signal 12 VDC / 1 mA
    OFF position Yes – output 0 V, dry contact open
    Dry contact Yes (load limit not stated on the product page)
    Installation Flush-mounted (standard European box) or surface-mounted
    Protection class IP44 flush-mounted / IP54 surface-mounted

    Main functions

    • Supply from the EC fan – no separate power source needed.
    • OFF position with detent – the fan is switched off with the knob.
    • Dry contact – external equipment on / off together with the knob.
    • Stepless signal – stepless from 0 V to Us.

    Where is it used?

    • EC fans with an auxiliary DC output
    • Apartments, offices, small commercial premises
    • Sentera EVS / MVS controllers and FI-E frequency inverters
    • Damper actuators

    On-demand operation

    For the installer.
    Three wires to the fan – quick connection.
    For the designer.
    The most economical manual control option.
    For the user.
    Clear OFF position and stepless control.

    Application guide: how it is used in practice

    MTPNX10K-NA can be adapted to different sites – only what is connected changes:

    Site What is connected Result Installer's note
    EC fan with a 10 V output Supply ← fan 10 V; signal → control input Manual control 0–10 V with OFF Check the fan's output voltage in its documentation
    Fan with damper Dry contact → damper actuator circuit The damper opens when leaving OFF Check the contact load in the datasheet
    AC fan with a Sentera EVS / MVS controller 0-10 V → controller analogue input Controller in the control panel, control in the room Connect the signal GND to the controller GND
    FI-E series frequency inverter 0-10 V → inverter analogue input Manual three-phase fan speed setting Check the inverter input setting (0-10 V)

    How to select the controller current

    Rated current of the motor(s) Recommended model
    OFF position needed, supply 24 VAC / DC MTPNG010-AT (OFF, 0-10 VDC)
    Continuous min. signal needed (no OFF), 3–15 VDC MTPND010-BT (no OFF, 0-10 V)
    Auxiliary contact needed (e.g. to start a frequency inverter) MTPND010-DC (no OFF, dry contact)
    Supply from the EC fan needed, 10 kΩ, with OFF MTPNX10K-NA (10 kΩ, OFF, dry contact) ← this model
    Rule: Choose MTPNX10K-NA when the controlled device supplies DC voltage (up to 12 VDC) to the potentiometer and its input is suitable for a 10 kΩ potentiometer. If limit trimmers or another signal type are needed – choose MTPNG010-AT or SDP-E0US.
    When to choose another solution: with 0-20 mA / PWM output and trimmers – SDP-E0US series; with Modbus RTU – SDP-M010 or SPV-8 series; for 230 VAC supply – MTVN1 series; for AC fans – electronic EVS or MVS controllers controlled by this potentiometer. Equivalent SDP series model – SDP-X10K-NA (up to 24 VDC, dry contact 1 A).

    Pros

    • Supplied from the EC fan
    • OFF position with detent
    • Dry contact
    • Simple connection

    Cons / limitations

    • No Vmin / Vmax trimmers
    • Output equals the supply voltage (max. 12 VDC)
    • No 0-20 mA, PWM or Modbus
    • The dry contact load limit is not stated on the product page

    Safety and installation notes

    • Installation and connection must be carried out by a qualified electrician with the supply to all connected devices disconnected.
    • Supply – only from the DC output of the controlled device, no more than 12 VDC; connecting mains voltage is prohibited.
    • Analogue signal – max. 12 VDC / 1 mA.
    • Clean only with a damp cloth.

    Quick selection guide

    10 kΩ
    0–12 VDC
    OFF
    dry contact
    IP44 / IP54
    Suitable when you need:
    • control an EC fan without a separate power supply;
    • switch off the fan with the knob;
    • switch on external equipment at the same time.
    Check before use:
    • whether the EC fan has a DC output for a potentiometer;
    • whether its input is suitable for a 10 kΩ potentiometer;
    • the external equipment current through the dry contact.
    Important reminder: MTPNX10K-NA is a control signal source, not a power controller – the motor current does not flow through it.

    FAQ

    Is a power supply unit required?
    No, the potentiometer is supplied from the EC fan (0–12 VDC).
    Does it have an OFF position?
    Yes – knob fully counter-clockwise: output 0 V, contact open.
    What is the resistance?
    10 kΩ.
    Can the min. speed be limited?
    No, there are no trimmers – for that choose MTPNG010-AT or SDP-E0US.

    Potentiometer for EC fan 10kΩ with OFF position and dry contact | Sentera Controls | MTPNX10K-NA

    Sentera MTPNX10K-NA – 10 kΩ potentiometer for EC fans: supplied from the fan 0–12 VDC, stepless 0 V–Us signal, OFF position and dry contact, IP44 / IP54.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals