Potentiometer for EC fan with auxiliary contact | Sentera Controls | MTPND010-DC
Code: MTPND010-DCOffer is valid until 2026-12-31Price 35.40 € VAT incl.( 29.26 € VAT excl. )55.24 €You save 19.84 €Want another price? Suggest yours!-
Potentiometer for EC fan with auxiliary contact | Sentera Controls | MTPND010-DC
MTPND010-DC – Sentera Controls potentiometer for EC fans with an additional (dry) contact, supplied with 3–15 VDC. The 0-10 V control signal is changed with the knob, and the Vmin and Vmax limits are set with internal trimmers.
Key idea:
The potentiometer has no OFF position: when the knob is turned fully, the set minimum signal remains – the fan runs at least at min. speed. The auxiliary dry contact is intended, e.g., for activating a frequency inverter.Power supply
3–15 VDCOutput
0-10 VAuxiliary contact
Dry contact (e.g. for a frequency inverter)Protection
IP44 / IP54Operating principle
The potentiometer is installed in a living or working room, while the controlled EC fan, controller or frequency inverter is in a technical room or control panel. A 3–15 VDC supply and the 0-10 V output signal are connected, and the dry contact – into the start circuit of the inverter or other device.
This is not a power controller – it only generates a control signal, and the speed is changed by the EC motor or controller itself.
Vmin is set within 10–70 % and Vmax within 30–100 % of the supply voltage with internal trimmers. To access them, remove the knob, unscrew the nut and remove the front cover.
Engineer's note: since there is no OFF position, the min. signal never reaches 0 V – set Vmin deliberately, according to the min. required air volume.
Benefits MTPND010-DC?
A compact, low-cost manual control solution for EC fans, AC controllers and frequency inverters with a 0-10 V input. The contact allows the inverter to be started at the same time.Technical specifications
Product type Potentiometer for an EC fan Manufacturer / code Sentera Controls / MTPND010-DC Supply voltage 3–15 VDC Output signal 0-10 V Vmin (internal trimmer) 10–70 % of supply voltage Vmax (internal trimmer) 30–100 % of supply voltage OFF position None Auxiliary contact Dry contact (e.g. to enable a frequency inverter) Terminals Screw-type, 2 cable glands Installation Flush-mounted (standard European box) or surface-mounted Protection class IP44 flush-mounted / IP54 surface-mounted Main functions
- Stepless 0-10 V signal – the speed changes steplessly.
- Vmin / Vmax trimmers – speed limits are adapted to the specific site.
- No OFF position – the fan always runs at least at min. speed.
- Dry contact – remote enabling of a frequency inverter or other device.
- Universal enclosure – suitable for masonry, plasterboard and timber walls, IP44 / IP54.
Where is it used?
- Apartments and houses with EC fans
- Offices and workspaces
- AC fans with Sentera EVS / MVS controllers
- Fans with FI-E frequency inverters
- Damper actuators
On-demand operation
For the installer.
Fits a standard European flush-mounted box – quick installation.For the designer.
One potentiometer for EC, AC controllers and frequency inverters.For the user.
Simple graduated knob, speed increases when turned clockwise.Application guide: how it is used in practice
MTPND010-DC can be adapted to different sites – only what is connected to its output changes:
Site What is connected Result Installer's note Apartment or house with an EC fan 0-10 V output → EC fan control input Manual stepless ventilation control Potentiometer in a living room, fan in a technical room AC fan with a Sentera EVS / MVS controller 0-10 V → controller analogue input Controller in the control panel, control in the room Connect the signal GND to the controller GND FI-E series frequency inverter 0-10 V → analogue input; dry contact → inverter start (RUN) input The inverter is started and controlled with a single potentiometer Check the contact load limit in the datasheet Damper with a proportional actuator 0-10 V → actuator control input Manual damper position setting The actuator must accept a 0-10 V signal How to select the controller current
Rated current of the motor(s) Recommended model OFF position needed, supply 24 VAC / DC MTPNG010-AT (OFF, 0-10 VDC) Continuous min. signal needed (no OFF), 3–15 VDC MTPND010-BT (no OFF, 0-10 V) Auxiliary contact needed (e.g. to start a frequency inverter) MTPND010-DC (no OFF, dry contact) ← this model Supply from the EC fan needed, 10 kΩ, with OFF MTPNX10K-NA (10 kΩ, OFF, dry contact) Rule: choose according to your needs and the available supply: OFF needed – MTPNG010-AT (24 VAC / DC); constant min. signal – MTPND010-BT; additional contact – MTPND010-DC; supply from the EC fan – MTPNX10K-NA. Motor power has no influence on the selection.When to choose another solution: with 0-20 mA / PWM output and trimmers – SDP-E0US series; with Modbus RTU – SDP-M010 or SPV-8 series; for 230 VAC supply – MTVN1 series; for AC fans – electronic EVS or MVS controllers controlled by this potentiometer.Pros
- Auxiliary dry contact
- Stepless 0-10 V signal
- Vmin / Vmax limits
- Continuous min. ventilation
- Flush-mounted or surface-mounted installation
Cons / limitations
- No OFF position
- A 3–15 VDC supply is required
- Trimmers are accessible only after removing the cover
- No Modbus, 0-20 mA or PWM output
- The dry contact load limit is not stated on the product page
Safety and installation notes
- Installation and connection must be carried out by a qualified electrician with the supply to all connected devices disconnected.
- Supply – only 3–15 VDC; connecting mains voltage is prohibited.
- Before connecting, check the input type of the controlled device (0-10 V).
- Clean only with a damp cloth.
Quick selection guide
3–15 VDC0-10 Vbe OFFIP44 / IP54dry contactSuitable when you need:- control an EC fan manually with a 0-10 V signal;
- ensure constant min. ventilation;
- start a frequency inverter at the same time via the dry contact.
Check before use:- the available 3–15 VDC supply;
- the 0-10 V input of the controlled device;
- whether an OFF position is needed – if so, MTPNG010-AT.
Important reminder: MTPND010-DC is a control signal source, not a power controller – the motor current does not flow through it.FAQ
Does it have an OFF position?
No. When the knob is turned fully, the set min. signal remains.Where are the trimmers?
Under the front cover: remove the knob, unscrew the nut and remove the cover.Is it suitable for a frequency inverter?
Yes, Sentera specifies FI-E series frequency inverters. The inverter can also be enabled via the dry contact.Can it be powered from 24 VDC?
No – the specified supply is 3–15 VDC; for 24 VAC / DC choose MTPNG010-AT.Potentiometer for EC fan with auxiliary contact | Sentera Controls | MTPND010-DC
Sentera MTPND010-DC – potentiometer for EC fans with an additional contact: 3–15 VDC supply, 0-10 V output, Vmin / Vmax trimmers, no OFF position, IP44 / IP54.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review