Potentiometer for EC fan with auxiliary contact | Sentera Controls | SPV-8-010-CP
Code: SPV-8-010-CPOffer is valid until 2026-12-31Price 81.36 € VAT incl.( 67.24 € VAT excl. )126.92 €You save 45.56 €Want another price? Suggest yours!-
Potentiometer for EC fan with auxiliary contact | Sentera Controls | SPV-8-010-CP
SPV-8-010-CP – Sentera Controls 230 VAC potentiometer with Modbus RTU and dry contact, designed for stepless control of EC motors with a 0-10 VDC, 0-20 mA or 0–100 % PWM signal. Supplied with 85–264 VAC, while Vmin, Vmax, direction and output type are set via Modbus RTU.
Key idea:
The potentiometer is supplied directly from the mains and is also a Modbus RTU device – the BMS sees and changes its settings, while the user in the room has a familiar knob. In the leftmost knob position a dry contact (up to 4 A) is switched for external equipment.Power supply
85–264 VAC, 50–60 HzAO1 output
0-10 VDC / 0-20 mA / PWM 1 kHzCommunication
Modbus RTU (RS485)OFF / contact
Dry contact 4 AOperating principle
The potentiometer is connected to the 85–264 VAC mains (L, N), the Modbus RTU line (A, /B) and the input of the controlled device (AO1, GND), the dry contact – into the external device circuit.
This is not a power controller – it only generates a control signal, and the speed is changed by the electronics of the EC motors themselves.
AO1 modes: 0-10 VDC (RL ≥ 50 kΩ), 0-20 mA (RL ≤ 500 Ω), PWM 1 kHz (RL ≥ 50 kΩ). Vmin is set to 0–4 VDC / 0–8 mA / 0–40 % PWM, Vmax – 6–10 VDC / 12–20 mA / 60–100 % PWM via Modbus RTU; the control direction is also selected there.
Engineer's note: the bootloader mode allows the firmware to be updated via Modbus RTU, so the device can be updated already installed on site.
Benefits SPV-8-010-CP?
Mains supply, Modbus RTU and manual control in one flush-mounted enclosure – no 24 V power supply unit or separate Modbus module needed.Technical specifications
Product type 230 VAC potentiometer with Modbus RTU for an EC fan Manufacturer / code Sentera Controls / SPV-8-010-CP Series SPV-8 (PM – with OFF, CP – with dry contact, MF – for several EC fans) Supply voltage 85–264 VAC, 50–60 Hz AO1 output – voltage 0-10 VDC, RL ≥ 50 kΩ AO1 output – current 0-20 mA, RL ≤ 500 Ω AO1 output – PWM 1 kHz, RL ≥ 50 kΩ Vmin 0–4 VDC / 0–8 mA / 0–40 % PWM (via Modbus RTU) Vmax 6–10 VDC / 12–20 mA / 60–100 % PWM (via Modbus RTU) Control direction Min.→max. or max.→min. (via Modbus RTU) Dry contact (CS) Max. 4 A, switched in the leftmost knob position Communication Modbus RTU (RS485), bootloader for updates Terminals Push-in, 1.5 mm², pitch 3.5 mm Installation Flush-mounted (IP44) or surface-mounted (IP54) Protection class IP44 / IP54 (EN 60529) Operating environment 0–40 °C, 5–95 % rH non-condensing Weight 0.16 kg (net) Compliance LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EU Manufacturer documentation
✔ Recommended by Elektrotechnikos sprendimaiOriginal manufacturer documentation – technical data, wiring diagrams and installation instructions.
Main functions
- Supply from the mains 85–264 VAC – no 24 V power supply unit needed.
- Modbus RTU – Vmin, Vmax and direction are set remotely; the device is visible in the BMS.
- Three output types – 0-10 VDC, 0-20 mA or PWM 1 kHz.
- Dry contact up to 4 A – switches external equipment in the left position.
- Bootloader – firmware updates via Modbus RTU.
- Universal enclosure – flush-mounted IP44 or surface-mounted IP54, push-in terminals.
Where is it used?
- Offices, halls, hotels with BMS
- EC duct and roof fans
- Rooms without 24 V automation
- AC fans with EVS / MVS controllers
- Damper actuators
On-demand operation
For the automation / BMS integrator.
Settings via Modbus RTU, firmware update possible.For the electrician.
Supply from the existing 230 VAC line.For the user.
A conventional knob in the room.Application guide: how it is used in practice
SPV-8-010-CP can be adapted to different sites – only what is connected changes:
Site What is connected Result Installer's note Office or hall with BMS Modbus RTU → A, /B; AO1 → EC fan Manual control, the BMS sees the setting A unique Modbus address for each device Room without 24 V automation L, N ← 230 VAC; AO1 → EC fan Control without a power supply unit Route signal and mains cables separately AC fan with an electronic controller AO1 (0-10 VDC) → Sentera EVS / MVS controller input Manual AC fan control Signal GND – to the controller GND Damper with a 0-20 mA actuator AO1 (0-20 mA) → actuator Manual damper control In current mode, load ≤ 500 Ω Fan with a damper or heater Dry contact → external device circuit Auxiliary equipment is switched on together Contact load ≤ 4 A How to select the controller current
Rated current of the motor(s) Recommended model OFF and Modbus RTU needed, one EC fan SPV-8-010-PM (OFF, Modbus RTU) Dry contact (4 A) and Modbus RTU needed SPV-8-010-CP (dry contact 4 A, Modbus RTU) ← this model Control of several EC fans with one signal needed SPV-8-010-MF (0-10 VDC, RL ≥ 1 kΩ, dry contact 4 A) EBM-Papst FFU control via Modbus / DCI needed (up to 20 pcs) SPVL8-010-EP (Modbus / DCI, up to 20 fans) Rule: choose according to your needs: one EC fan and OFF – PM; external equipment needs to be controlled – CP (contact 4 A); a group of several fans with one signal – MF (total input resistance ≥ 1 kΩ); EBM-Papst FFU with DCI – SPVL8-010-EP. Motor power has no influence on the selection.When to choose another solution: without Modbus with 230 VAC supply – MTVN1 series; with a display and steps – RDCV9-AD; 24 VDC with Modbus – SDP-M010 series; EBM-Papst FFU – SPVL8-010-EP; for an air heater with an EC fan – ECH-8-DM.Pros
- Dry contact up to 4 A
- Three output types
- Supply 85–264 VAC
- Modbus RTU
- Vmin / Vmax and direction via Modbus
- IP44 / IP54
Cons / limitations
- Operating temperature only 0–40 °C
- Limits can be changed only via Modbus RTU (a converter and software are required)
- The terminals carry mains voltage: installation by a qualified electrician only
Safety and installation notes
- Installation and connection must be carried out by a qualified electrician with the supply to all connected devices disconnected.
- The terminals carry mains voltage – connect only with the supply disconnected.
- Observe the output load limits: voltage / PWM ≥ 50 kΩ, current ≤ 500 Ω.
- Dry contact load – no more than 4 A.
- Connect the Modbus line with twisted-pair cable, in a line topology.
Quick selection guide
85–264 VACModbus RTU0-10 V / 0-20 mA / PWMdry contact 4 AIP44 / IP54Suitable when you need:- control an EC fan from 230 VAC without a power supply unit;
- integrate manual control into the BMS via Modbus RTU;
- switch on external equipment at the same time (up to 4 A).
Check before use:- the type and resistance of the controlled input;
- the Modbus address plan and RS485 topology;
- whether OFF, a dry contact or control of several fans is needed.
Important reminder: SPV-8-010-CP is a control signal source, not a power controller – the motor current does not flow through it.FAQ
Is a 24 V supply required?
No, it is supplied with 85–264 VAC, 50–60 Hz.How do I change Vmin / Vmax?
Via Modbus RTU, e.g. with a CNVT-USB-RS485 converter and the Sentera 3SModbus software.How many fans can be connected?
As many as stay within the load limits; for a group of several fans choose SPV-8-010-MF.Can it be used without Modbus?
Yes, as a manual potentiometer with factory settings.Potentiometer for EC fan with auxiliary contact | Sentera Controls | SPV-8-010-CP
Sentera SPV-8-010-CP – 230 VAC potentiometer with dry contact and Modbus RTU: 85–264 VAC, 0-10 VDC / 0-20 mA / PWM output, dry contact 4 A, Vmin / Vmax via Modbus, IP44 / IP54.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions