SPV-8-010-MF – Sentera Controls 230 VAC potentiometer with Modbus RTU, designed for stepless control of several EC motors with a single 0-10 VDC signal. Vmin (0–4 VDC) and Vmax (6–10 VDC) are set via Modbus RTU, and the dry contact (up to 4 A) switches on an external device remotely.
Key idea:
One potentiometer – a whole group of fans: the output allows a load down to RL ≥ 1 kΩ, so the control inputs of several EC fans can be connected in parallel and their speed changed simultaneously.Power supply
85–264 VAC, 50–60 HzAO1 output
0-10 VDC (RL ≥ 1 kΩ)Communication
Modbus RTU (RS485)OFF / contact
Dry contact 4 AOperating principle
The potentiometer is connected to the 85–264 VAC mains (L, N), the Modbus RTU line (A, /B) and the input of the controlled device (AO1, GND), the dry contact – into the external device circuit.
This is not a power controller – it only generates a control signal, and the speed is changed by the electronics of the EC motors themselves.
Turning the knob changes AO1 steplessly between Vmin (0–4 VDC) and Vmax (6–10 VDC); normal (min.→max.) or reverse logic is selected via Modbus RTU. Output load – RL ≥ 1 kΩ.
Engineer's note: the number of fans connected in parallel is not specified in the datasheet – it is determined by the input impedance. For n identical inputs with impedance Ri, the total impedance Ri / n must be ≥ 1 kΩ (e.g. inputs of 10 kΩ each – no more than 10 pcs).
Benefits SPV-8-010-MF?
Mains supply, Modbus RTU and manual control in one flush-mounted enclosure – no 24 V power supply unit or separate Modbus module needed. A whole group of fans is controlled with a single signal.Technical specifications
Product type 230 VAC potentiometer with Modbus RTU for several EC fans Manufacturer / code Sentera Controls / SPV-8-010-MF Series SPV-8 (PM – with OFF, CP – with dry contact, MF – for several EC fans) Supply voltage 85–264 VAC, 50–60 Hz AO1 output 0-10 VDC, RL ≥ 1 kΩ Vmin / Vmax 0–4 VDC / 6–10 VDC (via Modbus RTU) Dry contact Max. 4 A, remote ON / OFF Communication Modbus RTU (RS485); firmware update, unique ID Terminals Supply – spring terminals 2.5 mm², pitch 5 mm; signals – push-in 1.5 mm², pitch 3.5 mm Housing ASA, white Installation Flush-mounted (IP44) or surface-mounted (IP54) Protection class IP44 / IP54 Operating environment 0–65 °C, 5–95 % rH non-condensing (storage -10…+70 °C) Weight 0.20 kg (net) Compliance LVD 2014/35/EU, EMC 2014/30/EU, RoHS (EU) 2015/863, WEEE 2012/19/EU Manufacturer documentation
✔ Recommended by Elektrotechnikos sprendimaiOriginal manufacturer documentation – technical data, wiring diagrams and installation instructions.
Main functions
- Supply from the mains 85–264 VAC – no 24 V power supply unit needed.
- Modbus RTU – Vmin, Vmax and direction are set remotely; the device is visible in the BMS.
- Several EC fans with one signal – output load down to RL ≥ 1 kΩ.
- Dry contact up to 4 A – remote ON / OFF of external equipment.
- Normal / reverse logic – the speed increases or decreases as the knob is turned.
- Universal enclosure – flush-mounted IP44 or surface-mounted IP54, push-in terminals.
Where is it used?
- Offices, halls, hotels with BMS
- EC duct and roof fans
- Rooms without 24 V automation
- AC fans with EVS / MVS controllers
- Damper actuators
On-demand operation
For the automation / BMS integrator.
Settings via Modbus RTU, firmware update possible.For the electrician.
Supply from the existing 230 VAC line.For the user.
A conventional knob in the room.Application guide: how it is used in practice
SPV-8-010-MF can be adapted to different sites – only what is connected changes:
Site What is connected Result Installer's note A group of several fans (e.g. roof fans) AO1 → 0-10 V inputs of all EC fans in parallel All fans change speed synchronously Total input impedance ≥ 1 kΩ Office or hall with BMS Modbus RTU → A, /B; AO1 → EC fan Manual control, the BMS sees the setting A unique Modbus address for each device Room without 24 V automation L, N ← 230 VAC; AO1 → EC fan Control without a power supply unit Route signal and mains cables separately AC fan with an electronic controller AO1 (0-10 VDC) → Sentera EVS / MVS controller input Manual AC fan control Signal GND – to the controller GND Damper with a proportional actuator AO1 (0-10 VDC) → actuator Manual damper position control Sentera also lists this application Fan with a damper or heater Dry contact → external device circuit Auxiliary equipment is switched on together Contact load ≤ 4 A How to select the controller current
Rated current of the motor(s) Recommended model OFF and Modbus RTU needed, one EC fan SPV-8-010-PM (OFF, Modbus RTU) Dry contact (4 A) and Modbus RTU needed SPV-8-010-CP (dry contact 4 A, Modbus RTU) Control of several EC fans with one signal needed SPV-8-010-MF (0-10 VDC, RL ≥ 1 kΩ, dry contact 4 A) ← this model EBM-Papst FFU control via Modbus / DCI needed (up to 20 pcs) SPVL8-010-EP (Modbus / DCI, up to 20 fans) Rule: choose according to your needs: one EC fan and OFF – PM; external equipment needs to be controlled – CP (contact 4 A); a group of several fans with one signal – MF (total input resistance ≥ 1 kΩ); EBM-Papst FFU with DCI – SPVL8-010-EP. Motor power has no influence on the selection.When to choose another solution: without Modbus with 230 VAC supply – MTVN1 series; with a display and steps – RDCV9-AD; 24 VDC with Modbus – SDP-M010 series; EBM-Papst FFU – SPVL8-010-EP; for an air heater with an EC fan – ECH-8-DM.Pros
- Several EC fans with one signal
- Dry contact up to 4 A
- Operating temperature up to 65 °C
- Supply 85–264 VAC
- Modbus RTU
- Vmin / Vmax and direction via Modbus
- IP44 / IP54
Cons / limitations
- 0-10 VDC only – no 0-20 mA or PWM
- The number of fans is limited by the load RL ≥ 1 kΩ
- Limits can be changed only via Modbus RTU (a converter and software are required)
- The terminals carry mains voltage: installation by a qualified electrician only
Safety and installation notes
- Installation and connection must be carried out by a qualified electrician with the supply to all connected devices disconnected.
- The terminals carry mains voltage – connect only with the supply disconnected.
- Observe the output load limits: RL ≥ 1 kΩ.
- Dry contact load – no more than 4 A.
- Connect the Modbus line with twisted-pair cable, in a line topology.
Quick selection guide
85–264 VACModbus RTU0-10 VDCdry contact 4 AIP44 / IP54Suitable when you need:- control an EC fan from 230 VAC without a power supply unit;
- integrate manual control into the BMS via Modbus RTU;
- control several EC fans with a single signal.
Check before use:- the type and resistance of the controlled input;
- the Modbus address plan and RS485 topology;
- whether OFF, a dry contact or control of several fans is needed.
Important reminder: SPV-8-010-MF is a control signal source, not a power controller – the motor current does not flow through it.FAQ
Is a 24 V supply required?
No, it is supplied with 85–264 VAC, 50–60 Hz.How do I change Vmin / Vmax?
Via Modbus RTU, e.g. with a CNVT-USB-RS485 converter and the Sentera 3SModbus software.How many fans can be connected?
As many as keep the total input resistance ≥ 1 kΩ.Can it be used without Modbus?
Yes, as a manual potentiometer with factory settings.Potentiometer for several EC fans with dry contact | Sentera Controls | SPV-8-010-MF
Sentera SPV-8-010-MF – 230 VAC potentiometer for multiple EC fans with Modbus RTU: 85–264 VAC, 0-10 VDC output RL ≥ 1 kΩ, dry contact 4 A, Vmin / Vmax via Modbus, IP44 / IP54.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review