  • Selective main circuit breaker (SLS) | 3P | 35A | E | 25kA | 400V | Eaton xPole | LSHU-E35/3-AD

    Code: LSHU-E35/3-AD

    A selective three-phase circuit breaker designed for reliable protection of electrical circuits against short circuits and overloads. The breaker is engineered to disconnect only the faulty section of the circuit in the event of a fault, while maintaining operation of the remaining system. This is especially important in residential, commercial, and industrial electrical installations where maximum reliability and uninterrupted operation are required. 

  • Selective main circuit breaker (SLS) | 3P | 35A | E | 25kA | 400V | Eaton xPole | LSHU-E35/3-AD

    Eaton xPole LSHU-E35/3-AD – a three-phase selective main circuit breaker (SLS) with a 35 A rated current, E characteristic and 25 kA breaking capacity. Designed for the building service entrance upstream of the electricity meter, where it replaces the main fuses.

    Key idea:
    In the event of a fault, the main SLS breaker lets the downstream circuit breaker trip first while it stays switched on itself. This way a short circuit in one circuit does not disconnect the whole house or apartment.
    Rated current
    35 A, 3P
    Characteristic
    E (selective)
    Breaking capacity
    Icn 25 kA
    Voltage
    230/400 V AC

    How it works

    The breaker is installed in the service entrance zone upstream of the meter, with all three phases connected to it. Each pole has its own tripping mechanism.

    The E characteristic is designed for selectivity: during a short circuit the breaker briefly limits the current and lets the downstream 6 or 10 kA, energy limiting class 3 circuit breaker trip. If the fault persists, the SLS itself disconnects.

    The result – only the faulty circuit is disconnected, while the rest of the building stays powered.

    Why choose the LSHU-E35/3?
    Instead of main fuses, you get resettable, reusable protection with selectivity – no fuse links to replace, and the service entrance stays protected up to 25 kA.

    Technical specifications

    Product typeSelective main circuit breaker (SLS)
    Manufacturer / seriesEaton (Moeller) xPole LSHU
    ModelLSHU-E35/3-AD
    Number of poles3P
    Rated current35 A
    Rated voltage230/400 V AC, 50–60 Hz
    CharacteristicE
    Breaking capacityIcn 25 kA
    Selectivitywith downstream 6 / 10 kA, energy limiting class 3 circuit breakers
    Insulation voltage Ui690 V
    Impulse withstand voltage6 kV
    Terminals2.5–50 mm², tightening torque 4 N·m
    Width1.5 modules per pole
    Service lifeat least 4 000 cycles at rated current
    StandardsDIN VDE 0641-21, VDE-AR-N 4101

    Key functions

    • Selectivity – only the faulty circuit trips, not the entire service entrance.
    • Overload and short-circuit protection – protects the incoming cable and the meter.
    • 25 kA breaking capacity – suitable for supplies close to a transformer substation.
    • Separate tripping of each pole – can be switched back on after a fault without replacing fuses.
    • Does not close onto an existing short circuit – safer re-energising of the supply after repairs.

    Where is it used?

    • Residential service entrances upstream of the meter
    • Apartment supplies in multi-storey buildings
    • Main distribution boards in commercial premises
    • Meter cabinets
    • Replacing main fuses with modern protection
    • Service entrances of small industrial sites

    Use by need

    For the electrical installer.
    Service entrance protection without fuse links and with clear selectivity logic.
    For the homeowner.
    If one circuit fails, the rest of the house stays powered.
    For the designer.
    25 kA and the E characteristic make it possible to ensure selectivity with the final circuit breakers.

    Practical use

    If a short circuit occurs in the kitchen circuit, that circuit's 16 A circuit breaker trips, while the LSHU-E35/3 at the service entrance stays on – the fridge, heating and lighting keep working.

    Pros

    • Selectivity with final circuit breakers
    • Icn 25 kA
    • Resettable, no fuse replacement
    • Terminals up to 50 mm²
    • Compliant with DIN VDE 0641-21

    Cons / limitations

    • More expensive than a standard 3P circuit breaker
    • Selectivity is ensured only with energy limiting class 3 final circuit breakers
    • Check the mounting method and position in the board against the -AD version documentation and meter cabinet requirements
    • Does not protect against residual current

    Safety and installation notes

    • Work on the service entrance must be carried out only by a qualified electrician in agreement with the grid operator.
    • The 35 A rated current must match the permitted supply capacity and cable cross-section.
    • Tighten the terminals to 4 N·m.
    • Install energy limiting class 3 circuit breakers downstream so that selectivity works.
    • Before switching on, check that the short-circuit fault has been cleared.

    Quick selection guide

    3P | 35 A
    E | 25 kA
    SLS for service entrance
    230/400 V AC
    Suitable when you need:
    • selective service entrance protection upstream of the meter;
    • to replace main fuses;
    • to prevent a single circuit fault from disconnecting the whole building.
    Check before use:
    • whether 35 A matches the permitted supply capacity;
    • whether the grid operator requires an SLS;
    • whether the final circuit breakers are energy limiting class 3.
    Important reminder: an SLS breaker protects the service entrance, but does not replace a residual current device (RCD) or a surge protective device (SPD).

    FAQ

    What is an SLS breaker?
    A selective main circuit breaker installed at the service entrance upstream of the meter instead of fuses.
    What does the E characteristic mean?
    It is a selective characteristic that lets the downstream circuit breaker trip first.
    Can it be used instead of a standard 3P breaker?
    Yes, but its advantage is selectivity at the service entrance; standard MCBs are sufficient for final circuits.
    What cable sizes can be connected?
    From 2.5 to 50 mm².
    Does it need replacing after a fault?
    No – once the fault is cleared, simply switch the breaker back on.
    Does it protect against electric shock?
    No – that requires a residual current device (RCD).

    Selective main circuit breaker (SLS) | 3P | 35A | E | 25kA | 400V | Eaton xPole | LSHU-E35/3-AD

    Eaton xPole LSHU-E35/3-AD – a 3P 35 A selective main circuit breaker with E characteristic and 25 kA breaking capacity. Modern service entrance protection upstream of the meter, where a fault in one circuit must not disconnect the whole building.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information